Trina Solar TSM-275PD0510 is a 275.0 W STC (247.3 W PTC) Multi-c-Si solar module ranking #18,259 of 21,677 CEC listings (below all-CEC median; higher than 14.3% of peers). It delivers 16.8% efficiency, 38.5 V Voc at 25 C, and 43.18 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 275.0 W
- PTC Wattage
- 247.3 W
- Voc @ 25C
- 38.5 V
- Efficiency
- 16.8%
How Does Trina Solar TSM-275PD0510 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Trina Solar TSM-275PD0510 (Multi-c-Si) residential solar systems.
Homeowners evaluating Trina Solar TSM-275PD0510 need 22 panels for 6 kW or 30 panels (529 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (529 sq ft). Under NEC 690.7(A), beta_Voc (-0.347%/C) pushes open-circuit voltage to 43.18 V at 14 F and 44.51 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Trina Solar TSM-275PD0510 Fall Across Listed CEC Models?
Comparison of Trina Solar TSM-275PD0510 (275.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Dataset Percentiles Define Trina Solar TSM-275PD0510?
Relative ranking of Trina Solar TSM-275PD0510 across nameplate watts, 89.9% PTC thermal ratio, and module aperture efficiency. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What Do the Dataset Ranks Show for Trina Solar TSM-275PD0510?
Summary of Trina Solar TSM-275PD0510 output rank, 8 kW array size (30 panels), efficiency rating, and 600 V string limit.
275.0 W STC · Higher Than 14.3%
275.0 W STC (-110.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.8% Aperture Efficiency
Power density 168.0 W/m2 (3.11 percentage points below 19.91% CEC median). PTC/STC ratio: 89.9% (rank #19,247).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.18 V at -10 C (561.3 V string) and 44.51 V at -20 C (13 max).
30 Panels = 8,250 W STC
Occupies 49.1 m2 (529 sq ft) producing 7,419 W PTC; NEC 690.8 OCPD floor is 14.43 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.5 * (1 + (-0.347/100) * (-10 - 25)) = 43.18 V | OCPD = 1.56 * 9.25 = 14.43 A
Inputs from CEC Modules.csv for Trina Solar TSM-275PD0510: Voc=38.5 V, beta_Voc=-0.347%/C, Isc=9.25 A, STC=275.0 W, Area=1.637 m2.
Result: 13 panels max on 600 V (561.3 V); 30 panels for 8 kW (529 sq ft).
What Are the Published CEC Specifications for Trina Solar TSM-275PD0510?
Complete CEC test sheet for Trina Solar TSM-275PD0510 including Isc (9.25 A), Voc (38.5 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 275.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 247.3 W (89.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.25 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.1 V / 8.84 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.347 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.8% (1.637 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Trina Solar TSM-275PD0510 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Trina Solar TSM-275PD0510.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.05 kW | 388 sq ft | $1,514 | $2,561 |
| 8 kW Class | 30 | 8.25 kW | 529 sq ft | $2,065 | $3,492 |
| 10 kW Class | 37 | 10.18 kW | 652 sq ft | $2,548 | $4,308 |
How Many Trina Solar TSM-275PD0510 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Trina Solar TSM-275PD0510 (38.5 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.51 V | 13 panels | 578.6 V | 22 panels |
| -10 C (14 F) | 43.18 V | 13 panels | 561.3 V | 23 panels |
| 0 C (32 F) | 41.84 V | 14 panels | 585.8 V | 23 panels |
| 25 C (77 F STC) | 38.5 V | 15 panels | 577.5 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-275PD0510?
Four comparable CEC modules such as AXITEC AC-275P/60S (275.0 W) for side-by-side solar quote checks. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-275P/60S AXITEC |
275.0 W | Tie (0 W) | 38.5 V | 16.87% | 92.2% |
| AXITEC AC-275P/60V AXITEC |
275.0 W | Tie (0 W) | 38.5 V | 16.87% | 92.2% |
| GCL System Integration Technology Co Ltd GCL-M6/60275 GCL System Integration Technology Co Ltd |
275.0 W | Tie (0 W) | 38.5 V | 16.87% | 90.0% |
| GCL System Integration Technology Co Ltd GCL-P6/60275 GCL System Integration Technology Co Ltd |
275.0 W | Tie (0 W) | 38.5 V | 16.9% | 90.7% |
What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-275PD0510?
Evaluate Trina Solar TSM-275PD0510 (275.0 W STC, 38.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-275PD0510 reaches 44.51 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 529 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (529 sq ft).
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-275PD0510 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Trina Solar TSM-275PD0510 8 kW Residential Fit
Needs 30 modules (529 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-275P/60S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 247.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Trina Solar TSM-275PD0510 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Trina Solar TSM-275PD0510 PTC wattage (247.3 W) lower than STC (275.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 247.3 W PTC (89.9% retention) across Trina Solar TSM-275PD0510's 1.637 m2 aperture.
Who should skip Trina Solar TSM-275PD0510 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 30 Trina Solar TSM-275PD0510 panels (529 sq ft) leave unusable roof gaps vs. AXITEC AC-275P/60S.
What is the 1,000 V commercial string limit for Trina Solar TSM-275PD0510?
On 1,000 V commercial inverters at -10 C (43.18 V cold Voc), Trina Solar TSM-275PD0510 fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Trina Solar TSM-275PD0510.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)