Trina Solar TSM-275PD05052 is a 275.0 W STC (247.3 W PTC) Multi-c-Si solar module ranking #18,259 of 21,677 CEC listings (below all-CEC median; higher than 14.3% of peers). It delivers 16.8% efficiency, 38.5 V Voc at 25 C, and 43.18 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 275.0 W
- PTC Wattage
- 247.3 W
- Voc @ 25C
- 38.5 V
- Efficiency
- 16.8%
How Does Trina Solar TSM-275PD05052 Compare Against Peer CEC Listings?
Engineering position of Trina Solar TSM-275PD05052 (275.0 W STC) vs. AXITEC AC-275P/60S across 1,407 CEC Multi-c-Si solar modules.
Ranking #18,259 across 21,677 CEC solar panels (below all-CEC median; higher than 14.3% of peers), Trina Solar TSM-275PD05052 operates as a compact residential or specialty off-grid module sitting 3.8 W below the 278.8 W Multi-c-Si median. Lower 38.5 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters. With typical 89.9% PTC-to-STC thermal output (247.3 W real-world rating), 30 panels occupy 529 sq ft and offset roughly $2,065/yr at average US rates (or $3,492/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Trina Solar TSM-275PD05052 Fall Across Listed CEC Models?
Plots Trina Solar TSM-275PD05052 at 275.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Trina Solar TSM-275PD05052?
Benchmarks Trina Solar TSM-275PD05052 on STC wattage, thermal PTC/STC retention, and 16.8 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Trina Solar TSM-275PD05052?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Trina Solar TSM-275PD05052 by Trina Solar.
275.0 W STC · Higher Than 14.3%
275.0 W STC (-110.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.8% Aperture Efficiency
Power density 168.0 W/m2 (3.11 percentage points below 19.91% CEC median). PTC/STC ratio: 89.9% (rank #19,247).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.18 V at -10 C (561.3 V string) and 44.51 V at -20 C (13 max).
30 Panels = 8,250 W STC
Occupies 49.1 m2 (529 sq ft) producing 7,419 W PTC; NEC 690.8 OCPD floor is 14.43 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.5 * (1 + (-0.347/100) * (-10 - 25)) = 43.18 V | OCPD = 1.56 * 9.25 = 14.43 A
Inputs from CEC Modules.csv for Trina Solar TSM-275PD05052: Voc=38.5 V, beta_Voc=-0.347%/C, Isc=9.25 A, STC=275.0 W, Area=1.637 m2.
Result: 13 panels max on 600 V (561.3 V); 30 panels for 8 kW (529 sq ft).
What Are the Published CEC Specifications for Trina Solar TSM-275PD05052?
Laboratory test ratings recorded for Trina Solar TSM-275PD05052 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 275.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 247.3 W (89.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.25 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.1 V / 8.84 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.347 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.8% (1.637 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Trina Solar TSM-275PD05052 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (529 sq ft at 8 kW), and estimated Year-1 electric bill offset for Trina Solar TSM-275PD05052.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.05 kW | 388 sq ft | $1,514 | $2,561 |
| 8 kW Class | 30 | 8.25 kW | 529 sq ft | $2,065 | $3,492 |
| 10 kW Class | 37 | 10.18 kW | 652 sq ft | $2,548 | $4,308 |
How Many Trina Solar TSM-275PD05052 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Trina Solar TSM-275PD05052 (beta_Voc -0.347%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.51 V | 13 panels | 578.6 V | 22 panels |
| -10 C (14 F) | 43.18 V | 13 panels | 561.3 V | 23 panels |
| 0 C (32 F) | 41.84 V | 14 panels | 585.8 V | 23 panels |
| 25 C (77 F STC) | 38.5 V | 15 panels | 577.5 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-275PD05052?
Closest cross-brand CEC competitors to Trina Solar TSM-275PD05052 matched near 275.0 W STC and 38.5 V Voc, led by AXITEC AC-275P/60S.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-275P/60S AXITEC |
275.0 W | Tie (0 W) | 38.5 V | 16.87% | 92.2% |
| AXITEC AC-275P/60V AXITEC |
275.0 W | Tie (0 W) | 38.5 V | 16.87% | 92.2% |
| GCL System Integration Technology Co Ltd GCL-M6/60275 GCL System Integration Technology Co Ltd |
275.0 W | Tie (0 W) | 38.5 V | 16.87% | 90.0% |
| GCL System Integration Technology Co Ltd GCL-P6/60275 GCL System Integration Technology Co Ltd |
275.0 W | Tie (0 W) | 38.5 V | 16.9% | 90.7% |
What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-275PD05052?
Evaluate Trina Solar TSM-275PD05052 (275.0 W STC, 38.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-275PD05052 reaches 44.51 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 529 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (529 sq ft).
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-275PD05052 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Trina Solar TSM-275PD05052 8 kW Residential Fit
Needs 30 modules (529 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-275P/60S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 247.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Trina Solar TSM-275PD05052 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Trina Solar TSM-275PD05052 panels fit on a 600 V winter solar string?
At -10 C (14 F), Trina Solar TSM-275PD05052 cold Voc rises from 38.5 V to 43.18 V (beta_Voc -0.347%/C), capping a 600 V string at 13 panels (561.3 V).
How much roof area does an 8 kW array of Trina Solar TSM-275PD05052 need?
An 8 kW DC system uses 30 Trina Solar TSM-275PD05052 modules (8,250 W STC / 7,419 W PTC), covering roughly 529 sq ft and saving ~$2,065/yr at 18.54 c/kWh.
How does Trina Solar TSM-275PD05052 compare against AXITEC AC-275P/60S?
Trina Solar TSM-275PD05052 outputs 275.0 W STC (38.5 V Voc, rank #18,259 of 21,677), while AXITEC AC-275P/60S delivers 275.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)