Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-270PD05082 is a 270.0 W STC (242.7 W PTC) Multi-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 16.5% efficiency, 38.4 V Voc at 25 C, and 43.06 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
270.0 W
PTC Wattage
242.7 W
Voc @ 25C
38.4 V
Efficiency
16.5%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-270PD05082 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Trina Solar TSM-270PD05082 (Multi-c-Si) residential solar systems.

Trina Solar TSM-270PD05082 delivers 164.9 W/m2 (3.41 percentage points below 19.91% CEC median) and typical 89.9% PTC-to-STC thermal output (242.7 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (529 sq ft). At -4 F (-20 C), string voltage climbs to 44.4 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with Bluesun Solar Energy Tech CoLtd BSM270M-60 (270.0 W).

Where Does Trina Solar TSM-270PD05082 Fall Across Listed CEC Models?

Comparison of Trina Solar TSM-270PD05082 (270.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-270PD05082 (270.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-27: 270.0 W

What Dataset Percentiles Define Trina Solar TSM-270PD05082?

Relative ranking of Trina Solar TSM-270PD05082 across nameplate watts, 89.9% PTC thermal ratio, and module aperture efficiency. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Trina Solar TSM-270PD05082 Engineering BenchmarksPercentile comparison of Trina Solar TSM-270PD05082 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage270.0 WPTC/STC Retention89.9%Module Efficiency16.5%

What Do the Dataset Ranks Show for Trina Solar TSM-270PD05082?

Summary of Trina Solar TSM-270PD05082 output rank, 8 kW array size (30 panels), efficiency rating, and 600 V string limit.

Rank #18,572 / 21,677

270.0 W STC · Higher Than 12.9%

270.0 W STC (-115.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,269

16.5% Aperture Efficiency

Power density 164.9 W/m2 (3.41 percentage points below 19.91% CEC median). PTC/STC ratio: 89.9% (rank #19,247).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.06 V at -10 C (559.8 V string) and 44.4 V at -20 C (13 max).

8 kW Reference Array

30 Panels = 8,100 W STC

Occupies 49.1 m2 (529 sq ft) producing 7,281 W PTC; NEC 690.8 OCPD floor is 14.32 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.4 * (1 + (-0.347/100) * (-10 - 25)) = 43.06 V | OCPD = 1.56 * 9.18 = 14.32 A

Inputs from CEC Modules.csv for Trina Solar TSM-270PD05082: Voc=38.4 V, beta_Voc=-0.347%/C, Isc=9.18 A, STC=270.0 W, Area=1.637 m2.

Result: 13 panels max on 600 V (559.8 V); 30 panels for 8 kW (529 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-270PD05082?

Complete CEC test sheet for Trina Solar TSM-270PD05082 including Isc (9.18 A), Voc (38.4 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-270PD05082.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 270.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 242.7 W (89.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.18 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.9 V / 8.73 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.347 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.5% (1.637 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Trina Solar TSM-270PD05082 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Trina Solar TSM-270PD05082.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.21 kW 405 sq ft $1,554 $2,628
8 kW Class 30 8.1 kW 529 sq ft $2,027 $3,428
10 kW Class 38 10.26 kW 670 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

Related Trina Solar power steps and black/silver trims consolidated into this Trina Solar TSM-270PD05082 series guide. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sibling CEC listings grouped into the Trina Solar TSM-270PD05082 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-265PD05082 265.0 W 243.2 W 38.3 V 30.8 V 16.37%
Trina Solar TSM-270PD05082 270.0 W 242.7 W 38.4 V 30.9 V 16.5%

How Many Trina Solar TSM-270PD05082 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Trina Solar TSM-270PD05082 (38.4 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=38.4V and beta_Voc=-0.347%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.4 V 13 panels 577.2 V 22 panels
-10 C (14 F) 43.06 V 13 panels 559.8 V 23 panels
0 C (32 F) 41.73 V 14 panels 584.2 V 23 panels
25 C (77 F STC) 38.4 V 15 panels 576.0 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-270PD05082?

Four comparable CEC modules such as Bluesun Solar Energy Tech CoLtd BSM270M-60 (270.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Bluesun Solar Energy Tech CoLtd BSM270M-60
Bluesun Solar Energy Tech CoLtd
270.0 W Tie (0 W) 38.46 V 16.6% 89.9%
DuCal Solar Technology LLC DST270M-60
DuCal Solar Technology LLC
270.0 W Tie (0 W) 38.46 V 16.6% 89.9%
AXITEC AC-270P/60S
AXITEC
270.0 W Tie (0 W) 38.31 V 16.56% 92.2%
AXITEC AC-270P/60V
AXITEC
270.0 W Tie (0 W) 38.31 V 16.56% 92.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-270PD05082?

Evaluate Trina Solar TSM-270PD05082 (270.0 W STC, 38.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-270PD05082 reaches 44.4 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 529 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (529 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-270PD05082 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-270PD05082 8 kW Residential Fit

Needs 30 modules (529 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM270M-60.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 242.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-270PD05082 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Trina Solar TSM-270PD05082 panels fit on a 600 V winter solar string?

At -10 C (14 F), Trina Solar TSM-270PD05082 cold Voc rises from 38.4 V to 43.06 V (beta_Voc -0.347%/C), capping a 600 V string at 13 panels (559.8 V).

How much roof area does an 8 kW array of Trina Solar TSM-270PD05082 need?

An 8 kW DC system uses 30 Trina Solar TSM-270PD05082 modules (8,100 W STC / 7,281 W PTC), covering roughly 529 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does Trina Solar TSM-270PD05082 compare against Bluesun Solar Energy Tech CoLtd BSM270M-60?

Trina Solar TSM-270PD05082 outputs 270.0 W STC (38.4 V Voc, rank #18,572 of 21,677), while Bluesun Solar Energy Tech CoLtd BSM270M-60 delivers 270.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.