Trina Solar TSM-245PD0500M is a 245.0 W STC (222.9 W PTC) Multi-c-Si solar module ranking #19,942 of 21,677 CEC listings (below all-CEC median; higher than 7.0% of peers). It delivers 15.14% efficiency, 37.3 V Voc at 25 C, and 41.87 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 245.0 W
- PTC Wattage
- 222.9 W
- Voc @ 25C
- 37.3 V
- Efficiency
- 15.14%
How Does Trina Solar TSM-245PD0500M Compare Against Peer CEC Listings?
Solar engineering breakdown for Trina Solar TSM-245PD0500M: PTC thermal retention, roof footprint, and cold Voc string bounds. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
Measured at 245.0 W STC and 222.9 W PTC, Trina Solar TSM-245PD0500M sits -140.0 W vs all-CEC median (below all-CEC median; higher than 7.0% of peers) among 21,677 listed modules. Power density reaches 151.4 W/m2 (4.77 percentage points below 19.91% CEC median). Lower 37.3 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 23 panels in series. Alternative peer Centrosolar America TP6 245xx rates 245.0 W.
Where Does Trina Solar TSM-245PD0500M Fall Across Listed CEC Models?
Distribution marker showing Trina Solar TSM-245PD0500M (245.0 W) relative to the 385.0 W all-CEC solar panel median. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What Dataset Percentiles Define Trina Solar TSM-245PD0500M?
Dataset percentiles tracking Trina Solar TSM-245PD0500M power output, thermal retention ratio, and aperture efficiency against 21,677 models. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Do the Dataset Ranks Show for Trina Solar TSM-245PD0500M?
Benchmark highlights for Trina Solar TSM-245PD0500M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
245.0 W STC · Higher Than 7.0%
245.0 W STC (-140.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.14% Aperture Efficiency
Power density 151.4 W/m2 (4.77 percentage points below 19.91% CEC median). PTC/STC ratio: 91.0% (rank #16,685).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.87 V at -10 C (586.2 V string) and 43.17 V at -20 C (13 max).
33 Panels = 8,085 W STC
Occupies 53.4 m2 (575 sq ft) producing 7,356 W PTC; NEC 690.8 OCPD floor is 13.21 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.3 * (1 + (-0.35/100) * (-10 - 25)) = 41.87 V | OCPD = 1.56 * 8.47 = 13.21 A
Inputs from CEC Modules.csv for Trina Solar TSM-245PD0500M: Voc=37.3 V, beta_Voc=-0.35%/C, Isc=8.47 A, STC=245.0 W, Area=1.618 m2.
Result: 14 panels max on 600 V (586.2 V); 33 panels for 8 kW (575 sq ft).
What Are the Published CEC Specifications for Trina Solar TSM-245PD0500M?
Official CEC datasheet figures for Trina Solar TSM-245PD0500M (Multi-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 245.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 222.9 W (91.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.47 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.7 V / 7.98 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.35 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.14% (1.618 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Trina Solar TSM-245PD0500M Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Trina Solar TSM-245PD0500M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 25 | 6.12 kW | 435 sq ft | $1,532 | $2,590 |
| 8 kW Class | 33 | 8.09 kW | 575 sq ft | $2,025 | $3,424 |
| 10 kW Class | 41 | 10.04 kW | 714 sq ft | $2,513 | $4,249 |
How Many Trina Solar TSM-245PD0500M Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Trina Solar TSM-245PD0500M (41.87 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.17 V | 13 panels | 561.2 V | 23 panels |
| -10 C (14 F) | 41.87 V | 14 panels | 586.2 V | 23 panels |
| 0 C (32 F) | 40.56 V | 14 panels | 567.8 V | 24 panels |
| 25 C (77 F STC) | 37.3 V | 16 panels | 596.8 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-245PD0500M?
Competing CEC solar panels closest to Trina Solar TSM-245PD0500M in nameplate wattage and Voc, starting with Centrosolar America TP6 245xx.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America TP6 245xx Centrosolar America |
245.0 W | Tie (0 W) | 37.3 V | 15.0% | 90.0% |
| Centrosolar America TP6S 245xx Centrosolar America |
245.0 W | Tie (0 W) | 37.3 V | 15.0% | 90.0% |
| Gintung Energy ASEC-245G6M6A Gintung Energy |
245.0 W | Tie (0 W) | 37.31 V | 15.21% | 89.6% |
| Gintung Energy GTEC-245G6M6A Gintung Energy |
245.0 W | Tie (0 W) | 37.31 V | 15.21% | 89.6% |
What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-245PD0500M?
Evaluate Trina Solar TSM-245PD0500M (245.0 W STC, 37.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-245PD0500M reaches 43.17 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 33 panels for an 8 kW build require 575 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 33 panels (575 sq ft).
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-245PD0500M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Trina Solar TSM-245PD0500M 8 kW Residential Fit
Needs 33 modules (575 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America TP6 245xx.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 222.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Trina Solar TSM-245PD0500M by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Trina Solar TSM-245PD0500M panels fit on a 600 V winter solar string?
At -10 C (14 F), Trina Solar TSM-245PD0500M cold Voc rises from 37.3 V to 41.87 V (beta_Voc -0.35%/C), capping a 600 V string at 14 panels (586.2 V).
How much roof area does an 8 kW array of Trina Solar TSM-245PD0500M need?
An 8 kW DC system uses 33 Trina Solar TSM-245PD0500M modules (8,085 W STC / 7,356 W PTC), covering roughly 575 sq ft and saving ~$2,025/yr at 18.54 c/kWh.
How does Trina Solar TSM-245PD0500M compare against Centrosolar America TP6 245xx?
Trina Solar TSM-245PD0500M outputs 245.0 W STC (37.3 V Voc, rank #19,942 of 21,677), while Centrosolar America TP6 245xx delivers 245.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)