Centrosolar America TP6S 245xx is a 245.0 W STC (220.4 W PTC) Multi-c-Si solar module ranking #19,942 of 21,677 CEC listings (below all-CEC median; higher than 7.0% of peers). It delivers 15.0% efficiency, 37.3 V Voc at 25 C, and 41.28 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 245.0 W
- PTC Wattage
- 220.4 W
- Voc @ 25C
- 37.3 V
- Efficiency
- 15.0%
How Does Centrosolar America TP6S 245xx Compare Against Peer CEC Listings?
How Centrosolar America Centrosolar America TP6S 245xx handles rooftop heat (220.4 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Centrosolar America TP6S 245xx exhibits 8.64 A short-circuit current, requiring a 13.48 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #19,942 of 21,677 (33.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 53.9 m2 for an 8 kW system (41 panels for 10 kW). Lower 37.3 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Centrosolar America TP6S 245xx Fall Across Listed CEC Models?
Where Centrosolar America TP6S 245xx (245.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Centrosolar America TP6S 245xx?
Percentile placement of Centrosolar America TP6S 245xx across power density (150.0 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Centrosolar America TP6S 245xx?
Four critical engineering numbers homeowners and solar installers check first when reviewing Centrosolar America TP6S 245xx specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
245.0 W STC · Higher Than 7.0%
245.0 W STC (-140.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.0% Aperture Efficiency
Power density 150.0 W/m2 (4.91 percentage points below 19.91% CEC median). PTC/STC ratio: 90.0% (rank #18,995).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.28 V at -10 C (577.9 V string) and 42.42 V at -20 C (14 max).
33 Panels = 8,085 W STC
Occupies 53.9 m2 (580 sq ft) producing 7,273 W PTC; NEC 690.8 OCPD floor is 13.48 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.3 * (1 + (-0.305/100) * (-10 - 25)) = 41.28 V | OCPD = 1.56 * 8.64 = 13.48 A
Inputs from CEC Modules.csv for Centrosolar America TP6S 245xx: Voc=37.3 V, beta_Voc=-0.305%/C, Isc=8.64 A, STC=245.0 W, Area=1.633 m2.
Result: 14 panels max on 600 V (577.9 V); 33 panels for 8 kW (580 sq ft).
What Are the Published CEC Specifications for Centrosolar America TP6S 245xx?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Centrosolar America TP6S 245xx.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 245.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 220.4 W (90.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.64 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.3 V / 8.13 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.305 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.0% (1.633 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Centrosolar America TP6S 245xx Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Centrosolar America TP6S 245xx (245.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 25 | 6.12 kW | 439 sq ft | $1,532 | $2,590 |
| 8 kW Class | 33 | 8.09 kW | 580 sq ft | $2,025 | $3,424 |
| 10 kW Class | 41 | 10.04 kW | 721 sq ft | $2,513 | $4,249 |
How Many Centrosolar America TP6S 245xx Modules Fit in a Cold-Weather String?
Maximum series module counts for Centrosolar America TP6S 245xx from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.42 V | 14 panels | 593.9 V | 23 panels |
| -10 C (14 F) | 41.28 V | 14 panels | 577.9 V | 24 panels |
| 0 C (32 F) | 40.14 V | 14 panels | 562.0 V | 24 panels |
| 25 C (77 F STC) | 37.3 V | 16 panels | 596.8 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Centrosolar America TP6S 245xx?
Alternative CEC solar modules from competing brands near Centrosolar America TP6S 245xx (245.0 W), including Gintung Energy ASEC-245G6M6A.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Gintung Energy ASEC-245G6M6A Gintung Energy |
245.0 W | Tie (0 W) | 37.31 V | 15.21% | 89.6% |
| Gintung Energy GTEC-245G6M6A Gintung Energy |
245.0 W | Tie (0 W) | 37.31 V | 15.21% | 89.6% |
| Eoplly New Energy Technology EP156P/60-245 AC Eoplly New Energy Technology |
245.0 W | Tie (0 W) | 37.38 V | 14.99% | 89.8% |
| Eoplly New Energy Technology EP156P/60-245W Eoplly New Energy Technology |
245.0 W | Tie (0 W) | 37.38 V | 14.99% | 89.8% |
What Are the Design Limits and Best-Fit Uses for Centrosolar America TP6S 245xx?
Evaluate Centrosolar America TP6S 245xx (245.0 W STC, 37.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America TP6S 245xx reaches 42.42 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 33 panels for an 8 kW build require 580 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 33 panels (580 sq ft).
- 2026 tax credit baseline: cash residential installs of Centrosolar America TP6S 245xx carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Centrosolar America TP6S 245xx 8 kW Residential Fit
Needs 33 modules (580 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Gintung Energy ASEC-245G6M6A.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 220.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Centrosolar America TP6S 245xx by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Centrosolar America TP6S 245xx PTC wattage (220.4 W) lower than STC (245.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 220.4 W PTC (90.0% retention) across Centrosolar America TP6S 245xx's 1.633 m2 aperture.
Who should skip Centrosolar America TP6S 245xx on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 33 Centrosolar America TP6S 245xx panels (580 sq ft) leave unusable roof gaps vs. Gintung Energy ASEC-245G6M6A.
What is the 1,000 V commercial string limit for Centrosolar America TP6S 245xx?
On 1,000 V commercial inverters at -10 C (41.28 V cold Voc), Centrosolar America TP6S 245xx fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Centrosolar America TP6S 245xx.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)