Gintung Energy GTEC-245G6M6A — CEC Solar Module Specifications

Manufacturer: Gintung Energy Registry: CEC Verified Engineering Specification

Gintung Energy GTEC-245G6M6A is a 245.0 W STC (219.5 W PTC) Multi-c-Si solar module ranking #19,942 of 21,677 CEC listings (below all-CEC median; higher than 7.0% of peers). It delivers 15.21% efficiency, 37.31 V Voc at 25 C, and 41.62 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
245.0 W
PTC Wattage
219.5 W
Voc @ 25C
37.31 V
Efficiency
15.21%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Gintung Energy GTEC-245G6M6A Compare Against Peer CEC Listings?

Engineering position of Gintung Energy GTEC-245G6M6A (245.0 W STC) vs. Centrosolar America TP6 245xx across 1,407 CEC Multi-c-Si solar modules.

Built with 60 Multi-c-Si cells, Gintung Energy GTEC-245G6M6A pairs typical 89.6% PTC-to-STC thermal output (219.5 W real-world rating) with 37.31 V nominal Voc. An 8 kW residential build (8,085 W DC, 7,244 W PTC) saves ~$2,025/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Centrosolar America TP6 245xx offers a 245.0 W alternative.

Where Does Gintung Energy GTEC-245G6M6A Fall Across Listed CEC Models?

Plots Gintung Energy GTEC-245G6M6A at 245.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Gintung Energy GTEC-245G6M6A (245.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCGintung Energy GTE: 245.0 W

What Dataset Percentiles Define Gintung Energy GTEC-245G6M6A?

Benchmarks Gintung Energy GTEC-245G6M6A on STC wattage, thermal PTC/STC retention, and 15.21 aperture conversion efficiency against CEC peers.

Gintung Energy GTEC-245G6M6A Engineering BenchmarksPercentile comparison of Gintung Energy GTEC-245G6M6A wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage245.0 WPTC/STC Retention89.6%Module Efficiency15.21%

What Do the Dataset Ranks Show for Gintung Energy GTEC-245G6M6A?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Gintung Energy GTEC-245G6M6A by Gintung Energy.

Rank #19,942 / 21,677

245.0 W STC · Higher Than 7.0%

245.0 W STC (-140.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,409

15.21% Aperture Efficiency

Power density 152.1 W/m2 (4.70 percentage points below 19.91% CEC median). PTC/STC ratio: 89.6% (rank #19,798).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.62 V at -10 C (582.7 V string) and 42.85 V at -20 C (14 max).

8 kW Reference Array

33 Panels = 8,085 W STC

Occupies 53.2 m2 (572 sq ft) producing 7,244 W PTC; NEC 690.8 OCPD floor is 13.53 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.31 * (1 + (-0.33/100) * (-10 - 25)) = 41.62 V | OCPD = 1.56 * 8.67 = 13.53 A

Inputs from CEC Modules.csv for Gintung Energy GTEC-245G6M6A: Voc=37.31 V, beta_Voc=-0.33%/C, Isc=8.67 A, STC=245.0 W, Area=1.611 m2.

Result: 14 panels max on 600 V (582.7 V); 33 panels for 8 kW (572 sq ft).

What Are the Published CEC Specifications for Gintung Energy GTEC-245G6M6A?

Laboratory test ratings recorded for Gintung Energy GTEC-245G6M6A (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy GTEC-245G6M6A.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 245.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 219.5 W (89.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.31 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.67 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.56 V / 8.29 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.33 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.21% (1.611 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Gintung Energy GTEC-245G6M6A Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (572 sq ft at 8 kW), and estimated Year-1 electric bill offset for Gintung Energy GTEC-245G6M6A.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 25 6.12 kW 434 sq ft $1,532 $2,590
8 kW Class 33 8.09 kW 572 sq ft $2,025 $3,424
10 kW Class 41 10.04 kW 711 sq ft $2,513 $4,249

Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?

Sibling wattage bins and frame colors grouped with Gintung Energy GTEC-245G6M6A under Gintung Energy to prevent duplicate spec pages.

Sibling CEC listings grouped into the Gintung Energy GTEC-245G6M6A wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Gintung Energy GTEC-240G6M6A 240.0 W 214.9 W 37.18 V 29.42 V 14.9%
Gintung Energy GTEC-245G6M6A 245.0 W 219.5 W 37.31 V 29.56 V 15.21%

How Many Gintung Energy GTEC-245G6M6A Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Gintung Energy GTEC-245G6M6A (beta_Voc -0.33%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.31V and beta_Voc=-0.33%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.85 V 14 panels 599.9 V 23 panels
-10 C (14 F) 41.62 V 14 panels 582.7 V 24 panels
0 C (32 F) 40.39 V 14 panels 565.5 V 24 panels
25 C (77 F STC) 37.31 V 16 panels 597.0 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Gintung Energy GTEC-245G6M6A?

Closest cross-brand CEC competitors to Gintung Energy GTEC-245G6M6A matched near 245.0 W STC and 37.31 V Voc, led by Centrosolar America TP6 245xx.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America TP6 245xx
Centrosolar America
245.0 W Tie (0 W) 37.3 V 15.0% 90.0%
Centrosolar America TP6S 245xx
Centrosolar America
245.0 W Tie (0 W) 37.3 V 15.0% 90.0%
Eoplly New Energy Technology EP156P/60-245 AC
Eoplly New Energy Technology
245.0 W Tie (0 W) 37.38 V 14.99% 89.8%
Eoplly New Energy Technology EP156P/60-245W
Eoplly New Energy Technology
245.0 W Tie (0 W) 37.38 V 14.99% 89.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Gintung Energy GTEC-245G6M6A?

Evaluate Gintung Energy GTEC-245G6M6A (245.0 W STC, 37.31 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy GTEC-245G6M6A reaches 42.85 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 33 panels for an 8 kW build require 572 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 33 panels (572 sq ft).
  • 2026 tax credit baseline: cash residential installs of Gintung Energy GTEC-245G6M6A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Gintung Energy GTEC-245G6M6A 8 kW Residential Fit

Needs 33 modules (572 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Centrosolar America TP6 245xx.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 219.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy GTEC-245G6M6A by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Gintung Energy GTEC-245G6M6A?

Multiplying Gintung Energy GTEC-245G6M6A's 8.67 A short-circuit current by 1.56 equals 13.53 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Gintung Energy GTEC-245G6M6A pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.62 V cold Voc at 14 F and handles 8.67 A Isc; string inverters cap Gintung Energy GTEC-245G6M6A at 14 panels on 600 V.

Is Gintung Energy GTEC-245G6M6A eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Gintung Energy GTEC-245G6M6A rely on utility bill offset (~$2,025/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.