Centrosolar America TP6 245xx is a 245.0 W STC (220.4 W PTC) Multi-c-Si solar module ranking #19,942 of 21,677 CEC listings (below all-CEC median; higher than 7.0% of peers). It delivers 15.0% efficiency, 37.3 V Voc at 25 C, and 41.28 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 245.0 W
- PTC Wattage
- 220.4 W
- Voc @ 25C
- 37.3 V
- Efficiency
- 15.0%
How Does Centrosolar America TP6 245xx Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Centrosolar America TP6 245xx (Multi-c-Si) residential solar systems.
Homeowners evaluating Centrosolar America TP6 245xx need 25 panels for 6 kW or 33 panels (580 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 33 panels (580 sq ft). Under NEC 690.7(A), beta_Voc (-0.305%/C) pushes open-circuit voltage to 41.28 V at 14 F and 42.42 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Centrosolar America TP6 245xx Fall Across Listed CEC Models?
Comparison of Centrosolar America TP6 245xx (245.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Centrosolar America TP6 245xx?
Relative ranking of Centrosolar America TP6 245xx across nameplate watts, 90.0% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Centrosolar America TP6 245xx?
Summary of Centrosolar America TP6 245xx output rank, 8 kW array size (33 panels), efficiency rating, and 600 V string limit.
245.0 W STC · Higher Than 7.0%
245.0 W STC (-140.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.0% Aperture Efficiency
Power density 150.0 W/m2 (4.91 percentage points below 19.91% CEC median). PTC/STC ratio: 90.0% (rank #18,995).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.28 V at -10 C (577.9 V string) and 42.42 V at -20 C (14 max).
33 Panels = 8,085 W STC
Occupies 53.9 m2 (580 sq ft) producing 7,273 W PTC; NEC 690.8 OCPD floor is 13.48 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.3 * (1 + (-0.305/100) * (-10 - 25)) = 41.28 V | OCPD = 1.56 * 8.64 = 13.48 A
Inputs from CEC Modules.csv for Centrosolar America TP6 245xx: Voc=37.3 V, beta_Voc=-0.305%/C, Isc=8.64 A, STC=245.0 W, Area=1.633 m2.
Result: 14 panels max on 600 V (577.9 V); 33 panels for 8 kW (580 sq ft).
What Are the Published CEC Specifications for Centrosolar America TP6 245xx?
Complete CEC test sheet for Centrosolar America TP6 245xx including Isc (8.64 A), Voc (37.3 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 245.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 220.4 W (90.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.64 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.3 V / 8.13 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.305 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.0% (1.633 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Centrosolar America TP6 245xx Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Centrosolar America TP6 245xx.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 25 | 6.12 kW | 439 sq ft | $1,532 | $2,590 |
| 8 kW Class | 33 | 8.09 kW | 580 sq ft | $2,025 | $3,424 |
| 10 kW Class | 41 | 10.04 kW | 721 sq ft | $2,513 | $4,249 |
How Many Centrosolar America TP6 245xx Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Centrosolar America TP6 245xx (37.3 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.42 V | 14 panels | 593.9 V | 23 panels |
| -10 C (14 F) | 41.28 V | 14 panels | 577.9 V | 24 panels |
| 0 C (32 F) | 40.14 V | 14 panels | 562.0 V | 24 panels |
| 25 C (77 F STC) | 37.3 V | 16 panels | 596.8 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Centrosolar America TP6 245xx?
Four comparable CEC modules such as Gintung Energy ASEC-245G6M6A (245.0 W) for side-by-side solar quote checks. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Gintung Energy ASEC-245G6M6A Gintung Energy |
245.0 W | Tie (0 W) | 37.31 V | 15.21% | 89.6% |
| Gintung Energy GTEC-245G6M6A Gintung Energy |
245.0 W | Tie (0 W) | 37.31 V | 15.21% | 89.6% |
| Eoplly New Energy Technology EP156P/60-245 AC Eoplly New Energy Technology |
245.0 W | Tie (0 W) | 37.38 V | 14.99% | 89.8% |
| Eoplly New Energy Technology EP156P/60-245W Eoplly New Energy Technology |
245.0 W | Tie (0 W) | 37.38 V | 14.99% | 89.8% |
What Are the Design Limits and Best-Fit Uses for Centrosolar America TP6 245xx?
Evaluate Centrosolar America TP6 245xx (245.0 W STC, 37.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America TP6 245xx reaches 42.42 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 33 panels for an 8 kW build require 580 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 33 panels (580 sq ft).
- 2026 tax credit baseline: cash residential installs of Centrosolar America TP6 245xx carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Centrosolar America TP6 245xx 8 kW Residential Fit
Needs 33 modules (580 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Gintung Energy ASEC-245G6M6A.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 220.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Centrosolar America TP6 245xx by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Centrosolar America TP6 245xx PTC wattage (220.4 W) lower than STC (245.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 220.4 W PTC (90.0% retention) across Centrosolar America TP6 245xx's 1.633 m2 aperture.
Who should skip Centrosolar America TP6 245xx on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 33 Centrosolar America TP6 245xx panels (580 sq ft) leave unusable roof gaps vs. Gintung Energy ASEC-245G6M6A.
What is the 1,000 V commercial string limit for Centrosolar America TP6 245xx?
On 1,000 V commercial inverters at -10 C (41.28 V cold Voc), Centrosolar America TP6 245xx fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Centrosolar America TP6 245xx.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)