Thornova Solar TS-SB60(460) is a 460.0 W STC (434.1 W PTC) Mono-c-Si solar module ranking #5,199 of 21,677 CEC listings (top 25.0%; higher than 75.0% of peers). It delivers 21.5% efficiency, 41.78 V Voc at 25 C, and 45.25 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 460.0 W
- PTC Wattage
- 434.1 W
- Voc @ 25C
- 41.78 V
- Efficiency
- 21.5%
How Does Thornova Solar TS-SB60(460) Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Thornova Solar TS-SB60(460) (Mono-c-Si) residential solar systems.
Homeowners evaluating Thornova Solar TS-SB60(460) need 14 panels for 6 kW or 18 panels (415 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 18 panels (415 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.237%/C) pushes open-circuit voltage to 45.25 V at 14 F and 46.24 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Thornova Solar TS-SB60(460) Fall Across Listed CEC Models?
Comparison of Thornova Solar TS-SB60(460) (460.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Thornova Solar TS-SB60(460)?
Relative ranking of Thornova Solar TS-SB60(460) across nameplate watts, 94.4% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Thornova Solar TS-SB60(460)?
Summary of Thornova Solar TS-SB60(460) output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.
Top 25.0% STC Output
460.0 W STC (+75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.5% Aperture Efficiency
Power density 215.0 W/m2 (1.59 percentage points above 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.25 V at -10 C (588.2 V string) and 46.24 V at -20 C (12 max).
18 Panels = 8,280 W STC
Occupies 38.5 m2 (415 sq ft) producing 7,814 W PTC; NEC 690.8 OCPD floor is 21.26 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.78 * (1 + (-0.237/100) * (-10 - 25)) = 45.25 V | OCPD = 1.56 * 13.63 = 21.26 A
Inputs from CEC Modules.csv for Thornova Solar TS-SB60(460): Voc=41.78 V, beta_Voc=-0.237%/C, Isc=13.63 A, STC=460.0 W, Area=2.14 m2.
Result: 13 panels max on 600 V (588.2 V); 18 panels for 8 kW (415 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-SB60(460)?
Complete CEC test sheet for Thornova Solar TS-SB60(460) including Isc (13.63 A), Voc (41.78 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 460.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 434.1 W (94.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.78 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.63 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.89 V / 13.19 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.237 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.5% (2.14 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Thornova Solar TS-SB60(460) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Thornova Solar TS-SB60(460).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.44 kW | 322 sq ft | $1,612 | $2,726 |
| 8 kW Class | 18 | 8.28 kW | 415 sq ft | $2,072 | $3,504 |
| 10 kW Class | 22 | 10.12 kW | 507 sq ft | $2,533 | $4,283 |
How Many Thornova Solar TS-SB60(460) Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Thornova Solar TS-SB60(460) (41.78 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.24 V | 12 panels | 554.9 V | 21 panels |
| -10 C (14 F) | 45.25 V | 13 panels | 588.2 V | 22 panels |
| 0 C (32 F) | 44.26 V | 13 panels | 575.4 V | 22 panels |
| 25 C (77 F STC) | 41.78 V | 14 panels | 584.9 V | 23 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-SB60(460)?
Four comparable CEC modules such as Aptos Solar Technology LLC DNA-120-MF10-460W (460.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-120-MF10-460W Aptos Solar Technology LLC |
460.0 W | Tie (0 W) | 41.7 V | 21.3% | 93.8% |
| Elin Energy (Sirius PV) ELNSM60M-HC-460 Elin Energy (Sirius PV) |
460.0 W | Tie (0 W) | 41.52 V | 21.4% | 94.3% |
| Elin Energy (Sirius PV) ELNSM60M-HC-LV-460 Elin Energy (Sirius PV) |
460.0 W | Tie (0 W) | 41.52 V | 21.4% | 94.3% |
| Aptos Solar Technology LLC DNA-120-BF10-460W Aptos Solar Technology LLC |
460.0 W | Tie (0 W) | 41.5 V | 21.3% | 94.3% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-SB60(460)?
Evaluate Thornova Solar TS-SB60(460) (460.0 W STC, 41.78 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-SB60(460) reaches 46.24 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (415 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-SB60(460) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-SB60(460) 8 kW Residential Fit
Needs 18 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Aptos Solar Technology LLC DNA-120-MF10-460W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 434.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-SB60(460) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Thornova Solar TS-SB60(460) PTC wattage (434.1 W) lower than STC (460.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 434.1 W PTC (94.4% retention) across Thornova Solar TS-SB60(460)'s 2.14 m2 aperture.
Who should skip Thornova Solar TS-SB60(460) on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 Thornova Solar TS-SB60(460) panels (415 sq ft) leave unusable roof gaps vs. Aptos Solar Technology LLC DNA-120-MF10-460W.
What is the 1,000 V commercial string limit for Thornova Solar TS-SB60(460)?
On 1,000 V commercial inverters at -10 C (45.25 V cold Voc), Thornova Solar TS-SB60(460) fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Thornova Solar TS-SB60(460).
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)