Manufacturer: Thornova Solar Registry: CEC Verified Engineering Specification

Thornova Solar TS-BGT78(645) is a 645.0 W STC (613.4 W PTC) Mono-c-Si solar module ranking #571 of 21,677 CEC listings (top 2.9%; higher than 97.1% of peers). It delivers 23.29% efficiency, 56.94 V Voc at 25 C, and 61.44 V cold Voc at -10 C (9 panels max per 600 V string).

STC Wattage
645.0 W
PTC Wattage
613.4 W
Voc @ 25C
56.94 V
Efficiency
23.29%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Thornova Solar TS-BGT78(645) Compare Against Peer CEC Listings?

Engineering position of Thornova Solar TS-BGT78(645) (645.0 W STC) vs. Heliene 156HC-645 M10 NTYP SL Bifacial across 5,889 CEC Mono-c-Si solar modules.

Ranking #571 across 21,677 CEC solar panels (top 2.9%; higher than 97.1% of peers), Thornova Solar TS-BGT78(645) operates as a large-format commercial and ground-mount module sitting 235.0 W above the 410.0 W Mono-c-Si median. Higher 56.94 V open-circuit voltage caps 600 V residential strings at 9 panels at 14 F (-10 C). With strong 95.1% PTC-to-STC heat retention (#713 of 21,677), 13 panels occupy 388 sq ft and offset roughly $2,097/yr at average US rates (or $3,547/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

Where Does Thornova Solar TS-BGT78(645) Fall Across Listed CEC Models?

Plots Thornova Solar TS-BGT78(645) at 645.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Thornova Solar TS-BGT78(645) (645.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCThornova Solar TS-: 645.0 W

What Dataset Percentiles Define Thornova Solar TS-BGT78(645)?

Benchmarks Thornova Solar TS-BGT78(645) on STC wattage, thermal PTC/STC retention, and 23.29 aperture conversion efficiency against CEC peers.

Thornova Solar TS-BGT78(645) Engineering BenchmarksPercentile comparison of Thornova Solar TS-BGT78(645) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage645.0 WPTC/STC Retention95.1%Module Efficiency23.29%

What Do the Dataset Ranks Show for Thornova Solar TS-BGT78(645)?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Thornova Solar TS-BGT78(645) by Thornova Solar.

Rank #571 / 21,677

Top 2.9% STC Output

645.0 W STC (+260.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #724

23.29% Aperture Efficiency

Power density 232.9 W/m2 (3.38 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).

NEC 690.7 Limit

9 Panels Max @ -10 C (600 V)

Cold Voc reaches 61.44 V at -10 C (553.0 V string) and 62.73 V at -20 C (9 max).

8 kW Reference Array

13 Panels = 8,385 W STC

Occupies 36.0 m2 (388 sq ft) producing 7,974 W PTC; NEC 690.8 OCPD floor is 21.82 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 56.94 * (1 + (-0.226/100) * (-10 - 25)) = 61.44 V | OCPD = 1.56 * 13.99 = 21.82 A

Inputs from CEC Modules.csv for Thornova Solar TS-BGT78(645): Voc=56.94 V, beta_Voc=-0.226%/C, Isc=13.99 A, STC=645.0 W, Area=2.77 m2.

Result: 9 panels max on 600 V (553.0 V); 13 panels for 8 kW (388 sq ft).

What Are the Published CEC Specifications for Thornova Solar TS-BGT78(645)?

Laboratory test ratings recorded for Thornova Solar TS-BGT78(645) (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Thornova Solar TS-BGT78(645).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 645.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 613.4 W (95.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 56.94 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.99 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 48.37 V / 13.34 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.226 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 23.29% (2.77 m2) Array roof footprint density
Cell Count & Technology 78 cells (Mono-c-Si) Bifacial glass-glass

How Many Thornova Solar TS-BGT78(645) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (388 sq ft at 8 kW), and estimated Year-1 electric bill offset for Thornova Solar TS-BGT78(645).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 10 6.45 kW 298 sq ft $1,614 $2,730
8 kW Class 13 8.38 kW 388 sq ft $2,097 $3,547
10 kW Class 16 10.32 kW 477 sq ft $2,583 $4,368

How Many Thornova Solar TS-BGT78(645) Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Thornova Solar TS-BGT78(645) (beta_Voc -0.226%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=56.94V and beta_Voc=-0.226%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 62.73 V 9 panels 564.6 V 15 panels
-10 C (14 F) 61.44 V 9 panels 553.0 V 16 panels
0 C (32 F) 60.16 V 9 panels 541.4 V 16 panels
25 C (77 F STC) 56.94 V 10 panels 569.4 V 17 panels

Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BGT78(645)?

Closest cross-brand CEC competitors to Thornova Solar TS-BGT78(645) matched near 645.0 W STC and 56.94 V Voc, led by Heliene 156HC-645 M10 NTYP SL Bifacial.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Heliene 156HC-645 M10 NTYP SL Bifacial
Heliene
645.0 W Tie (0 W) 57.85 V 23.12% 95.1%
JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD156N-R0-635
JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD
635.0 W -10.0 W 56.6 V 22.68% 94.6%
Philadelphia Solar PS-MNB156(HCBF)-635W
Philadelphia Solar
635.0 W -10.0 W 56.1 V 22.76% 94.3%
Heliene 156HC-615 M10 NTYP SL Bifacial
Heliene
615.0 W -30.0 W 56.92 V 22.04% 94.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BGT78(645)?

Evaluate Thornova Solar TS-BGT78(645) (645.0 W STC, 56.94 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BGT78(645) reaches 62.73 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 13 panels for an 8 kW build require 388 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BGT78(645) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Thornova Solar TS-BGT78(645) 8 kW Residential Fit

Needs 13 modules (388 sq ft) with a 25 A string OCPD, offsetting ~$2,097/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare Heliene 156HC-645 M10 NTYP SL Bifacial.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 613.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Thornova Solar TS-BGT78(645) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Thornova Solar TS-BGT78(645) panels fit on a 600 V winter solar string?

At -10 C (14 F), Thornova Solar TS-BGT78(645) cold Voc rises from 56.94 V to 61.44 V (beta_Voc -0.226%/C), capping a 600 V string at 9 panels (553.0 V).

How much roof area does an 8 kW array of Thornova Solar TS-BGT78(645) need?

An 8 kW DC system uses 13 Thornova Solar TS-BGT78(645) modules (8,385 W STC / 7,974 W PTC), covering roughly 388 sq ft and saving ~$2,097/yr at 18.54 c/kWh.

How does Thornova Solar TS-BGT78(645) compare against Heliene 156HC-645 M10 NTYP SL Bifacial?

Thornova Solar TS-BGT78(645) outputs 645.0 W STC (56.94 V Voc, rank #571 of 21,677), while Heliene 156HC-645 M10 NTYP SL Bifacial delivers 645.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.