Thornova Solar TS-BGT78(635) is a 635.0 W STC (603.6 W PTC) Mono-c-Si solar module ranking #710 of 21,677 CEC listings (top 3.6%; higher than 96.4% of peers). It delivers 22.92% efficiency, 56.56 V Voc at 25 C, and 61.03 V cold Voc at -10 C (9 panels max per 600 V string).
- STC Wattage
- 635.0 W
- PTC Wattage
- 603.6 W
- Voc @ 25C
- 56.56 V
- Efficiency
- 22.92%
How Does Thornova Solar TS-BGT78(635) Compare Against Peer CEC Listings?
Solar engineering breakdown for Thornova Solar TS-BGT78(635): PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Thornova Solar and peers, Thornova Solar TS-BGT78(635) stands 225.0 W above the 410.0 W Mono-c-Si median and strong 95.1% PTC-to-STC heat retention (#713 of 21,677). Sizing 6 kW (10 panels) to 10 kW (16 panels) yields $1,589-$2,543/yr in baseline US bill offset. Higher 56.56 V open-circuit voltage caps 600 V residential strings at 9 panels at 14 F (-10 C).
Where Does Thornova Solar TS-BGT78(635) Fall Across Listed CEC Models?
Distribution marker showing Thornova Solar TS-BGT78(635) (635.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Thornova Solar TS-BGT78(635)?
Dataset percentiles tracking Thornova Solar TS-BGT78(635) power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Thornova Solar TS-BGT78(635)?
Benchmark highlights for Thornova Solar TS-BGT78(635) covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 3.6% STC Output
635.0 W STC (+250.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.92% Aperture Efficiency
Power density 229.2 W/m2 (3.01 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).
9 Panels Max @ -10 C (600 V)
Cold Voc reaches 61.03 V at -10 C (549.3 V string) and 62.31 V at -20 C (9 max).
13 Panels = 8,255 W STC
Occupies 36.0 m2 (388 sq ft) producing 7,847 W PTC; NEC 690.8 OCPD floor is 21.67 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 56.56 * (1 + (-0.226/100) * (-10 - 25)) = 61.03 V | OCPD = 1.56 * 13.89 = 21.67 A
Inputs from CEC Modules.csv for Thornova Solar TS-BGT78(635): Voc=56.56 V, beta_Voc=-0.226%/C, Isc=13.89 A, STC=635.0 W, Area=2.77 m2.
Result: 9 panels max on 600 V (549.3 V); 13 panels for 8 kW (388 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-BGT78(635)?
Official CEC datasheet figures for Thornova Solar TS-BGT78(635) (Mono-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 635.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 603.6 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 56.56 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.89 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 47.99 V / 13.23 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.226 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.92% (2.77 m2) | Array roof footprint density |
| Cell Count & Technology | 78 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Thornova Solar TS-BGT78(635) Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Thornova Solar TS-BGT78(635) modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.35 kW | 298 sq ft | $1,589 | $2,687 |
| 8 kW Class | 13 | 8.26 kW | 388 sq ft | $2,067 | $3,496 |
| 10 kW Class | 16 | 10.16 kW | 477 sq ft | $2,543 | $4,300 |
How Many Thornova Solar TS-BGT78(635) Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Thornova Solar TS-BGT78(635) (61.03 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 62.31 V | 9 panels | 560.8 V | 16 panels |
| -10 C (14 F) | 61.03 V | 9 panels | 549.3 V | 16 panels |
| 0 C (32 F) | 59.76 V | 10 panels | 597.6 V | 16 panels |
| 25 C (77 F STC) | 56.56 V | 10 panels | 565.6 V | 17 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BGT78(635)?
Competing CEC solar panels closest to Thornova Solar TS-BGT78(635) in nameplate wattage and Voc, starting with JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD156N-R0-635.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD156N-R0-635 JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD |
635.0 W | Tie (0 W) | 56.6 V | 22.68% | 94.6% |
| Philadelphia Solar PS-MNB156(HCBF)-635W Philadelphia Solar |
635.0 W | Tie (0 W) | 56.1 V | 22.76% | 94.3% |
| Heliene 156HC-645 M10 NTYP SL Bifacial Heliene |
645.0 W | +10.0 W | 57.85 V | 23.12% | 95.1% |
| Philadelphia Solar PS-MNB156(HCBF)-620W Philadelphia Solar |
620.0 W | -15.0 W | 55.65 V | 22.22% | 94.3% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BGT78(635)?
Evaluate Thornova Solar TS-BGT78(635) (635.0 W STC, 56.56 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BGT78(635) reaches 62.31 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 13 panels for an 8 kW build require 388 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BGT78(635) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-BGT78(635) 8 kW Residential Fit
Needs 13 modules (388 sq ft) with a 25 A string OCPD, offsetting ~$2,067/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD156N-R0-635.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 603.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-BGT78(635) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-BGT78(635)?
Multiplying Thornova Solar TS-BGT78(635)'s 13.89 A short-circuit current by 1.56 equals 21.67 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Thornova Solar TS-BGT78(635) pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 61.03 V cold Voc at 14 F and handles 13.89 A Isc; string inverters cap Thornova Solar TS-BGT78(635) at 9 panels on 600 V.
Is Thornova Solar TS-BGT78(635) eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-BGT78(635) rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)