Thornova Solar TS-BGT66(700)-G12 is a 700.0 W STC (665.4 W PTC) Mono-c-Si solar module ranking #197 of 21,677 CEC listings (top 1.0%; higher than 99.0% of peers). It delivers 22.73% efficiency, 48.6 V Voc at 25 C, and 52.44 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 700.0 W
- PTC Wattage
- 665.4 W
- Voc @ 25C
- 48.6 V
- Efficiency
- 22.73%
How Does Thornova Solar TS-BGT66(700)-G12 Compare Against Peer CEC Listings?
Engineering position of Thornova Solar TS-BGT66(700)-G12 (700.0 W STC) vs. Nuuko Solar GmbH NKM695N-132BDG12 across 5,889 CEC Mono-c-Si solar modules.
Built with 66 Mono-c-Si cells, Thornova Solar TS-BGT66(700)-G12 pairs strong 95.1% PTC-to-STC heat retention (#713 of 21,677) with 48.6 V nominal Voc. An 8 kW residential build (8,400 W DC, 7,985 W PTC) saves ~$2,102/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer Nuuko Solar GmbH NKM695N-132BDG12 offers a 695.0 W alternative.
Where Does Thornova Solar TS-BGT66(700)-G12 Fall Across Listed CEC Models?
Plots Thornova Solar TS-BGT66(700)-G12 at 700.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Thornova Solar TS-BGT66(700)-G12?
Benchmarks Thornova Solar TS-BGT66(700)-G12 on STC wattage, thermal PTC/STC retention, and 22.73 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Thornova Solar TS-BGT66(700)-G12?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Thornova Solar TS-BGT66(700)-G12 by Thornova Solar.
Top 1.0% STC Output
700.0 W STC (+315.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.73% Aperture Efficiency
Power density 227.3 W/m2 (2.82 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.44 V at -10 C (576.8 V string) and 53.54 V at -20 C (11 max).
12 Panels = 8,400 W STC
Occupies 37.0 m2 (398 sq ft) producing 7,985 W PTC; NEC 690.8 OCPD floor is 28.58 A (30 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.6 * (1 + (-0.226/100) * (-10 - 25)) = 52.44 V | OCPD = 1.56 * 18.32 = 28.58 A
Inputs from CEC Modules.csv for Thornova Solar TS-BGT66(700)-G12: Voc=48.6 V, beta_Voc=-0.226%/C, Isc=18.32 A, STC=700.0 W, Area=3.08 m2.
Result: 11 panels max on 600 V (576.8 V); 12 panels for 8 kW (398 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-BGT66(700)-G12?
Laboratory test ratings recorded for Thornova Solar TS-BGT66(700)-G12 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 700.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 665.4 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 18.32 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.5 V / 17.29 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.226 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.73% (3.08 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Thornova Solar TS-BGT66(700)-G12 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (398 sq ft at 8 kW), and estimated Year-1 electric bill offset for Thornova Solar TS-BGT66(700)-G12.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 9 | 6.3 kW | 298 sq ft | $1,577 | $2,666 |
| 8 kW Class | 12 | 8.4 kW | 398 sq ft | $2,102 | $3,555 |
| 10 kW Class | 15 | 10.5 kW | 497 sq ft | $2,628 | $4,444 |
How Many Thornova Solar TS-BGT66(700)-G12 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Thornova Solar TS-BGT66(700)-G12 (beta_Voc -0.226%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.54 V | 11 panels | 588.9 V | 18 panels |
| -10 C (14 F) | 52.44 V | 11 panels | 576.8 V | 19 panels |
| 0 C (32 F) | 51.35 V | 11 panels | 564.9 V | 19 panels |
| 25 C (77 F STC) | 48.6 V | 12 panels | 583.2 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BGT66(700)-G12?
Closest cross-brand CEC competitors to Thornova Solar TS-BGT66(700)-G12 matched near 700.0 W STC and 48.6 V Voc, led by Nuuko Solar GmbH NKM695N-132BDG12.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Nuuko Solar GmbH NKM695N-132BDG12 Nuuko Solar GmbH |
695.0 W | -5.0 W | 48.24 V | 22.35% | 94.2% |
| SEG Solar Inc SEG-695-BTC-BG SEG Solar Inc |
695.0 W | -5.0 W | 47.7 V | 22.56% | 94.5% |
| ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-710/N ZNSHINE PV-TECH Co Ltd |
710.0 W | +10.0 W | 48.7 V | 22.9% | 95.6% |
| Nuuko Solar GmbH NKM710N-132BDG12 Nuuko Solar GmbH |
710.0 W | +10.0 W | 48.73 V | 22.83% | 94.3% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BGT66(700)-G12?
Evaluate Thornova Solar TS-BGT66(700)-G12 (700.0 W STC, 48.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BGT66(700)-G12 reaches 53.54 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 12 panels for an 8 kW build require 398 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BGT66(700)-G12 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-BGT66(700)-G12 8 kW Residential Fit
Needs 12 modules (398 sq ft) with a 30 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Nuuko Solar GmbH NKM695N-132BDG12.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 665.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-BGT66(700)-G12 by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-BGT66(700)-G12?
Multiplying Thornova Solar TS-BGT66(700)-G12's 18.32 A short-circuit current by 1.56 equals 28.58 A minimum ampacity, requiring at least a 30 A overcurrent fuse or breaker.
Can Thornova Solar TS-BGT66(700)-G12 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 52.44 V cold Voc at 14 F and handles 18.32 A Isc; string inverters cap Thornova Solar TS-BGT66(700)-G12 at 11 panels on 600 V.
Is Thornova Solar TS-BGT66(700)-G12 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-BGT66(700)-G12 rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)