Thornova Solar TS-BG60(445) is a 445.0 W STC (412.8 W PTC) Mono-c-Si solar module ranking #6,028 of 21,677 CEC listings (top 29.6%; higher than 70.4% of peers). It delivers 20.6% efficiency, 41.27 V Voc at 25 C, and 45.31 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 445.0 W
- PTC Wattage
- 412.8 W
- Voc @ 25C
- 41.27 V
- Efficiency
- 20.6%
How Does Thornova Solar TS-BG60(445) Compare Against Peer CEC Listings?
How Thornova Solar Thornova Solar TS-BG60(445) handles rooftop heat (412.8 W PTC), 8 kW sizing, and cold winter string voltage.
Thornova Solar builds the Thornova Solar TS-BG60(445) (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 206.0 W/m2 (0.69 percentage points above 19.91% CEC median). Compared against Elin Energy (Sirius PV) ELNSM60M-HC-BF-445 (445.0 W), this model holds strong 92.8% PTC-to-STC heat retention (#10,898 of 21,677). Mid-range 41.27 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 20.94 A overcurrent floor served by a 25 A breaker.
Where Does Thornova Solar TS-BG60(445) Fall Across Listed CEC Models?
Where Thornova Solar TS-BG60(445) (445.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Thornova Solar TS-BG60(445)?
Percentile placement of Thornova Solar TS-BG60(445) across power density (206.0 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Thornova Solar TS-BG60(445)?
Four critical engineering numbers homeowners and solar installers check first when reviewing Thornova Solar TS-BG60(445) specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
Top 29.6% STC Output
445.0 W STC (+60.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.6% Aperture Efficiency
Power density 206.0 W/m2 (0.69 percentage points above 19.91% CEC median). PTC/STC ratio: 92.8% (rank #10,898).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.31 V at -10 C (589.0 V string) and 46.47 V at -20 C (12 max).
18 Panels = 8,010 W STC
Occupies 38.9 m2 (419 sq ft) producing 7,430 W PTC; NEC 690.8 OCPD floor is 20.94 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.27 * (1 + (-0.28/100) * (-10 - 25)) = 45.31 V | OCPD = 1.56 * 13.42 = 20.94 A
Inputs from CEC Modules.csv for Thornova Solar TS-BG60(445): Voc=41.27 V, beta_Voc=-0.28%/C, Isc=13.42 A, STC=445.0 W, Area=2.16 m2.
Result: 13 panels max on 600 V (589.0 V); 18 panels for 8 kW (419 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-BG60(445)?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Thornova Solar TS-BG60(445).
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 445.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 412.8 W (92.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.27 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.42 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.46 V / 12.92 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.28 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.6% (2.16 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Thornova Solar TS-BG60(445) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Thornova Solar TS-BG60(445) (445.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.23 kW | 326 sq ft | $1,559 | $2,637 |
| 8 kW Class | 18 | 8.01 kW | 419 sq ft | $2,005 | $3,390 |
| 10 kW Class | 23 | 10.23 kW | 535 sq ft | $2,560 | $4,330 |
How Many Thornova Solar TS-BG60(445) Modules Fit in a Cold-Weather String?
Maximum series module counts for Thornova Solar TS-BG60(445) from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.47 V | 12 panels | 557.6 V | 21 panels |
| -10 C (14 F) | 45.31 V | 13 panels | 589.0 V | 22 panels |
| 0 C (32 F) | 44.16 V | 13 panels | 574.1 V | 22 panels |
| 25 C (77 F STC) | 41.27 V | 14 panels | 577.8 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BG60(445)?
Alternative CEC solar modules from competing brands near Thornova Solar TS-BG60(445) (445.0 W), including Elin Energy (Sirius PV) ELNSM60M-HC-BF-445.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Elin Energy (Sirius PV) ELNSM60M-HC-BF-445 Elin Energy (Sirius PV) |
445.0 W | Tie (0 W) | 41.22 V | 20.7% | 94.4% |
| Aptos Solar Technology LLC DNA-120-BF10-440W-USAptos2 Aptos Solar Technology LLC |
440.0 W | -5.0 W | 41.2 V | 20.56% | 94.3% |
| Aptos Solar Technology LLC DNA-120-BF10-440W-USAptos1 Aptos Solar Technology LLC |
440.0 W | -5.0 W | 41.18 V | 20.56% | 94.3% |
| Aptos Solar Technology LLC DNA-120-BF10-440W Aptos Solar Technology LLC |
440.0 W | -5.0 W | 41.11 V | 20.56% | 92.6% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BG60(445)?
Evaluate Thornova Solar TS-BG60(445) (445.0 W STC, 41.27 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BG60(445) reaches 46.47 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 419 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (419 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BG60(445) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-BG60(445) 8 kW Residential Fit
Needs 18 modules (419 sq ft) with a 25 A string OCPD, offsetting ~$2,005/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM60M-HC-BF-445.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 412.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-BG60(445) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-BG60(445)?
Multiplying Thornova Solar TS-BG60(445)'s 13.42 A short-circuit current by 1.56 equals 20.94 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Thornova Solar TS-BG60(445) pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 45.31 V cold Voc at 14 F and handles 13.42 A Isc; string inverters cap Thornova Solar TS-BG60(445) at 13 panels on 600 V.
Is Thornova Solar TS-BG60(445) eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-BG60(445) rely on utility bill offset (~$2,005/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)