Thornova Solar TS-BG54(405) is a 405.0 W STC (380.9 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.77% efficiency, 37.33 V Voc at 25 C, and 40.39 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 405.0 W
- PTC Wattage
- 380.9 W
- Voc @ 25C
- 37.33 V
- Efficiency
- 20.77%
How Does Thornova Solar TS-BG54(405) Compare Against Peer CEC Listings?
Engineering position of Thornova Solar TS-BG54(405) (405.0 W STC) vs. Belinus Solar BV BE-M7-GG-108-405 across 5,889 CEC Mono-c-Si solar modules.
Ranking #8,961 across 21,677 CEC solar panels (top 43.4%; higher than 56.6% of peers), Thornova Solar TS-BG54(405) operates as a modern high-density residential and light-commercial module sitting 5.0 W below the 410.0 W Mono-c-Si median. Lower 37.33 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With strong 94.0% PTC-to-STC heat retention (#4,745 of 21,677), 20 panels occupy 420 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.
Where Does Thornova Solar TS-BG54(405) Fall Across Listed CEC Models?
Plots Thornova Solar TS-BG54(405) at 405.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Thornova Solar TS-BG54(405)?
Benchmarks Thornova Solar TS-BG54(405) on STC wattage, thermal PTC/STC retention, and 20.77 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Thornova Solar TS-BG54(405)?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Thornova Solar TS-BG54(405) by Thornova Solar.
Top 43.4% STC Output
405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.77% Aperture Efficiency
Power density 207.7 W/m2 (0.86 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.39 V at -10 C (565.5 V string) and 41.26 V at -20 C (14 max).
20 Panels = 8,100 W STC
Occupies 39.0 m2 (420 sq ft) producing 7,618 W PTC; NEC 690.8 OCPD floor is 20.97 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.33 * (1 + (-0.234/100) * (-10 - 25)) = 40.39 V | OCPD = 1.56 * 13.44 = 20.97 A
Inputs from CEC Modules.csv for Thornova Solar TS-BG54(405): Voc=37.33 V, beta_Voc=-0.234%/C, Isc=13.44 A, STC=405.0 W, Area=1.95 m2.
Result: 14 panels max on 600 V (565.5 V); 20 panels for 8 kW (420 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-BG54(405)?
Laboratory test ratings recorded for Thornova Solar TS-BG54(405) (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 405.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 380.9 W (94.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.33 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.44 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.55 V / 12.84 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.234 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.77% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Thornova Solar TS-BG54(405) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (420 sq ft at 8 kW), and estimated Year-1 electric bill offset for Thornova Solar TS-BG54(405).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.08 kW | 315 sq ft | $1,522 | $2,573 |
| 8 kW Class | 20 | 8.1 kW | 420 sq ft | $2,027 | $3,428 |
| 10 kW Class | 25 | 10.12 kW | 525 sq ft | $2,533 | $4,283 |
How Many Thornova Solar TS-BG54(405) Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Thornova Solar TS-BG54(405) (beta_Voc -0.234%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.26 V | 14 panels | 577.6 V | 24 panels |
| -10 C (14 F) | 40.39 V | 14 panels | 565.5 V | 24 panels |
| 0 C (32 F) | 39.51 V | 15 panels | 592.6 V | 25 panels |
| 25 C (77 F STC) | 37.33 V | 16 panels | 597.3 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BG54(405)?
Closest cross-brand CEC competitors to Thornova Solar TS-BG54(405) matched near 405.0 W STC and 37.33 V Voc, led by Belinus Solar BV BE-M7-GG-108-405.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Belinus Solar BV BE-M7-GG-108-405 Belinus Solar BV |
405.0 W | Tie (0 W) | 37.36 V | 20.77% | 93.8% |
| Aptos Solar Technology LLC DNA-108-BF10-405W Aptos Solar Technology LLC |
405.0 W | Tie (0 W) | 37.23 V | 20.98% | 93.3% |
| Dehui Solar Power (Vietnam) CoLtd DH-M154T 405W Dehui Solar Power (Vietnam) CoLtd |
405.0 W | Tie (0 W) | 37.23 V | 20.98% | 93.3% |
| ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS ALTERNATIVE ENERGY (AE) SOLAR CO LTD |
405.0 W | Tie (0 W) | 37.2 V | 20.98% | 93.4% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BG54(405)?
Evaluate Thornova Solar TS-BG54(405) (405.0 W STC, 37.33 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BG54(405) reaches 41.26 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BG54(405) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-BG54(405) 8 kW Residential Fit
Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Belinus Solar BV BE-M7-GG-108-405.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 380.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-BG54(405) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Thornova Solar TS-BG54(405) panels fit on a 600 V winter solar string?
At -10 C (14 F), Thornova Solar TS-BG54(405) cold Voc rises from 37.33 V to 40.39 V (beta_Voc -0.234%/C), capping a 600 V string at 14 panels (565.5 V).
How much roof area does an 8 kW array of Thornova Solar TS-BG54(405) need?
An 8 kW DC system uses 20 Thornova Solar TS-BG54(405) modules (8,100 W STC / 7,618 W PTC), covering roughly 420 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does Thornova Solar TS-BG54(405) compare against Belinus Solar BV BE-M7-GG-108-405?
Thornova Solar TS-BG54(405) outputs 405.0 W STC (37.33 V Voc, rank #8,961 of 21,677), while Belinus Solar BV BE-M7-GG-108-405 delivers 405.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)