Thornova Solar TS-BBT72(595) is a 595.0 W STC (566.1 W PTC) Mono-c-Si solar module ranking #1,462 of 21,677 CEC listings (top 7.4%; higher than 92.6% of peers). It delivers 23.24% efficiency, 52.47 V Voc at 25 C, and 56.73 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 595.0 W
- PTC Wattage
- 566.1 W
- Voc @ 25C
- 52.47 V
- Efficiency
- 23.24%
How Does Thornova Solar TS-BBT72(595) Compare Against Peer CEC Listings?
How Thornova Solar Thornova Solar TS-BBT72(595) handles rooftop heat (566.1 W PTC), 8 kW sizing, and cold winter string voltage.
Thornova Solar builds the Thornova Solar TS-BBT72(595) (Mono-c-Si) as a large-format commercial and ground-mount module delivering 232.4 W/m2 (3.33 percentage points above 19.91% CEC median). Compared against CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT595-144TNB10 (595.0 W), this model holds strong 95.1% PTC-to-STC heat retention (#713 of 21,677). Higher 52.47 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 21.56 A overcurrent floor served by a 25 A breaker.
Where Does Thornova Solar TS-BBT72(595) Fall Across Listed CEC Models?
Where Thornova Solar TS-BBT72(595) (595.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Thornova Solar TS-BBT72(595)?
Percentile placement of Thornova Solar TS-BBT72(595) across power density (232.4 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Thornova Solar TS-BBT72(595)?
Four critical engineering numbers homeowners and solar installers check first when reviewing Thornova Solar TS-BBT72(595) specifications. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
Top 7.4% STC Output
595.0 W STC (+210.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.24% Aperture Efficiency
Power density 232.4 W/m2 (3.33 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 56.73 V at -10 C (567.3 V string) and 57.95 V at -20 C (10 max).
14 Panels = 8,330 W STC
Occupies 35.8 m2 (386 sq ft) producing 7,925 W PTC; NEC 690.8 OCPD floor is 21.56 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 52.47 * (1 + (-0.232/100) * (-10 - 25)) = 56.73 V | OCPD = 1.56 * 13.82 = 21.56 A
Inputs from CEC Modules.csv for Thornova Solar TS-BBT72(595): Voc=52.47 V, beta_Voc=-0.232%/C, Isc=13.82 A, STC=595.0 W, Area=2.56 m2.
Result: 10 panels max on 600 V (567.3 V); 14 panels for 8 kW (386 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-BBT72(595)?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Thornova Solar TS-BBT72(595).
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 595.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 566.1 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 52.47 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.82 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 44.85 V / 13.27 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.232 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.24% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Thornova Solar TS-BBT72(595) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Thornova Solar TS-BBT72(595) (595.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.54 kW | 303 sq ft | $1,637 | $2,768 |
| 8 kW Class | 14 | 8.33 kW | 386 sq ft | $2,085 | $3,525 |
| 10 kW Class | 17 | 10.12 kW | 468 sq ft | $2,533 | $4,283 |
How Many Thornova Solar TS-BBT72(595) Modules Fit in a Cold-Weather String?
Maximum series module counts for Thornova Solar TS-BBT72(595) from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 57.95 V | 10 panels | 579.5 V | 17 panels |
| -10 C (14 F) | 56.73 V | 10 panels | 567.3 V | 17 panels |
| 0 C (32 F) | 55.51 V | 10 panels | 555.1 V | 18 panels |
| 25 C (77 F STC) | 52.47 V | 11 panels | 577.2 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BBT72(595)?
Alternative CEC solar modules from competing brands near Thornova Solar TS-BBT72(595) (595.0 W), including CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT595-144TNB10.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT595-144TNB10 CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET |
595.0 W | Tie (0 W) | 52.85 V | 23.06% | 96.5% |
| Gautam Solar Pvt Ltd G2G1785-HAD Gautam Solar Pvt Ltd |
595.0 W | Tie (0 W) | 51.49 V | 23.18% | 95.2% |
| Gautam Solar Pvt Ltd G2X1785N-UHAD Gautam Solar Pvt Ltd |
595.0 W | Tie (0 W) | 51.49 V | 23.15% | 95.0% |
| Chint New Energy Technology Co Ltd CHSM72RN(DG)/F-BH-595 Chint New Energy Technology Co Ltd |
595.0 W | Tie (0 W) | 51.2 V | 22.04% | 94.7% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BBT72(595)?
Evaluate Thornova Solar TS-BBT72(595) (595.0 W STC, 52.47 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BBT72(595) reaches 57.95 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 386 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BBT72(595) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-BBT72(595) 8 kW Residential Fit
Needs 14 modules (386 sq ft) with a 25 A string OCPD, offsetting ~$2,085/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT595-144TNB10.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 566.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-BBT72(595) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-BBT72(595)?
Multiplying Thornova Solar TS-BBT72(595)'s 13.82 A short-circuit current by 1.56 equals 21.56 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Thornova Solar TS-BBT72(595) pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 56.73 V cold Voc at 14 F and handles 13.82 A Isc; string inverters cap Thornova Solar TS-BBT72(595) at 10 panels on 600 V.
Is Thornova Solar TS-BBT72(595) eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-BBT72(595) rely on utility bill offset (~$2,085/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)