Skip to main content
WireAndSun
Calculators
CEC PV Module

Thornova Solar TS-BBT72(585) — CEC Solar Module Specifications

Manufacturer: Thornova Solar Registry: CEC Verified Engineering Specification

Thornova Solar TS-BBT72(585) is a 585.0 W STC (556.4 W PTC) Mono-c-Si solar module ranking #1,751 of 21,677 CEC listings (top 8.7%; higher than 91.3% of peers). It delivers 22.85% efficiency, 52.09 V Voc at 25 C, and 56.32 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
585.0 W
PTC Wattage
556.4 W
Voc @ 25C
52.09 V
Efficiency
22.85%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Thornova Solar TS-BBT72(585) Compare Against Peer CEC Listings?

Engineering position of Thornova Solar TS-BBT72(585) (585.0 W STC) vs. CSI Solar Co Ltd CS6W-585TB-AG across 5,889 CEC Mono-c-Si solar modules.

Ranking #1,751 across 21,677 CEC solar panels (top 8.7%; higher than 91.3% of peers), Thornova Solar TS-BBT72(585) operates as a large-format commercial and ground-mount module sitting 175.0 W above the 410.0 W Mono-c-Si median. Higher 52.09 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C). With strong 95.1% PTC-to-STC heat retention (#713 of 21,677), 14 panels occupy 386 sq ft and offset roughly $2,050/yr at average US rates (or $3,466/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

Where Does Thornova Solar TS-BBT72(585) Fall Across Listed CEC Models?

Plots Thornova Solar TS-BBT72(585) at 585.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Thornova Solar TS-BBT72(585) (585.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCThornova Solar TS-: 585.0 W

What Dataset Percentiles Define Thornova Solar TS-BBT72(585)?

Benchmarks Thornova Solar TS-BBT72(585) on STC wattage, thermal PTC/STC retention, and 22.85 aperture conversion efficiency against CEC peers.

Thornova Solar TS-BBT72(585) Engineering BenchmarksPercentile comparison of Thornova Solar TS-BBT72(585) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage585.0 WPTC/STC Retention95.1%Module Efficiency22.85%

What Do the Dataset Ranks Show for Thornova Solar TS-BBT72(585)?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Thornova Solar TS-BBT72(585) by Thornova Solar.

Rank #1,751 / 21,677

Top 8.7% STC Output

585.0 W STC (+200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,413

22.85% Aperture Efficiency

Power density 228.5 W/m2 (2.94 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 56.32 V at -10 C (563.2 V string) and 57.53 V at -20 C (10 max).

8 kW Reference Array

14 Panels = 8,190 W STC

Occupies 35.8 m2 (386 sq ft) producing 7,790 W PTC; NEC 690.8 OCPD floor is 21.34 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 52.09 * (1 + (-0.232/100) * (-10 - 25)) = 56.32 V | OCPD = 1.56 * 13.68 = 21.34 A

Inputs from CEC Modules.csv for Thornova Solar TS-BBT72(585): Voc=52.09 V, beta_Voc=-0.232%/C, Isc=13.68 A, STC=585.0 W, Area=2.56 m2.

Result: 10 panels max on 600 V (563.2 V); 14 panels for 8 kW (386 sq ft).

What Are the Published CEC Specifications for Thornova Solar TS-BBT72(585)?

Laboratory test ratings recorded for Thornova Solar TS-BBT72(585) (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Thornova Solar TS-BBT72(585).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 585.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 556.4 W (95.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 52.09 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.68 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 44.61 V / 13.12 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.232 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.85% (2.56 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Thornova Solar TS-BBT72(585) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (386 sq ft at 8 kW), and estimated Year-1 electric bill offset for Thornova Solar TS-BBT72(585).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.43 kW 303 sq ft $1,609 $2,721
8 kW Class 14 8.19 kW 386 sq ft $2,050 $3,466
10 kW Class 18 10.53 kW 496 sq ft $2,636 $4,457

How Many Thornova Solar TS-BBT72(585) Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Thornova Solar TS-BBT72(585) (beta_Voc -0.232%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=52.09V and beta_Voc=-0.232%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 57.53 V 10 panels 575.3 V 17 panels
-10 C (14 F) 56.32 V 10 panels 563.2 V 17 panels
0 C (32 F) 55.11 V 10 panels 551.1 V 18 panels
25 C (77 F STC) 52.09 V 11 panels 573.0 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BBT72(585)?

Closest cross-brand CEC competitors to Thornova Solar TS-BBT72(585) matched near 585.0 W STC and 52.09 V Voc, led by CSI Solar Co Ltd CS6W-585TB-AG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS6W-585TB-AG
CSI Solar Co Ltd
585.0 W Tie (0 W) 52.4 V 23.31% 95.0%
Boviet Solar Technology Co Ltd BVM7612M-585-H-HC-BF
Boviet Solar Technology Co Ltd
585.0 W Tie (0 W) 52.61 V 22.67% 95.1%
Boviet Solar Technology Co Ltd BVM7612M-585-H-HC-BF-DG
Boviet Solar Technology Co Ltd
585.0 W Tie (0 W) 52.61 V 22.67% 95.1%
CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-585
CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI
585.0 W Tie (0 W) 51.5 V 22.85% 94.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BBT72(585)?

Evaluate Thornova Solar TS-BBT72(585) (585.0 W STC, 52.09 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BBT72(585) reaches 57.53 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 14 panels for an 8 kW build require 386 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BBT72(585) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Thornova Solar TS-BBT72(585) 8 kW Residential Fit

Needs 14 modules (386 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS6W-585TB-AG.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 556.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Thornova Solar TS-BBT72(585) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Thornova Solar TS-BBT72(585) panels fit on a 600 V winter solar string?

At -10 C (14 F), Thornova Solar TS-BBT72(585) cold Voc rises from 52.09 V to 56.32 V (beta_Voc -0.232%/C), capping a 600 V string at 10 panels (563.2 V).

How much roof area does an 8 kW array of Thornova Solar TS-BBT72(585) need?

An 8 kW DC system uses 14 Thornova Solar TS-BBT72(585) modules (8,190 W STC / 7,790 W PTC), covering roughly 386 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

How does Thornova Solar TS-BBT72(585) compare against CSI Solar Co Ltd CS6W-585TB-AG?

Thornova Solar TS-BBT72(585) outputs 585.0 W STC (52.09 V Voc, rank #1,751 of 21,677), while CSI Solar Co Ltd CS6W-585TB-AG delivers 585.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.