Thornova Solar TS-BBT54(455) is a 455.0 W STC (432.4 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 23.45% efficiency, 39.42 V Voc at 25 C, and 42.52 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 455.0 W
- PTC Wattage
- 432.4 W
- Voc @ 25C
- 39.42 V
- Efficiency
- 23.45%
How Does Thornova Solar TS-BBT54(455) Compare Against Peer CEC Listings?
Engineering position of Thornova Solar TS-BBT54(455) (455.0 W STC) vs. Aptos Solar Technology LLC DNA-108-BFN10-455W-DG across 5,889 CEC Mono-c-Si solar modules.
Built with 54 Mono-c-Si cells, Thornova Solar TS-BBT54(455) pairs strong 95.0% PTC-to-STC heat retention (#1,106 of 21,677) with 39.42 V nominal Voc. An 8 kW residential build (8,190 W DC, 7,783 W PTC) saves ~$2,050/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer Aptos Solar Technology LLC DNA-108-BFN10-455W-DG offers a 455.0 W alternative.
Where Does Thornova Solar TS-BBT54(455) Fall Across Listed CEC Models?
Plots Thornova Solar TS-BBT54(455) at 455.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Thornova Solar TS-BBT54(455)?
Benchmarks Thornova Solar TS-BBT54(455) on STC wattage, thermal PTC/STC retention, and 23.45 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Thornova Solar TS-BBT54(455)?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Thornova Solar TS-BBT54(455) by Thornova Solar.
Top 26.2% STC Output
455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.45% Aperture Efficiency
Power density 234.5 W/m2 (3.54 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.52 V at -10 C (595.3 V string) and 43.41 V at -20 C (13 max).
18 Panels = 8,190 W STC
Occupies 34.9 m2 (376 sq ft) producing 7,783 W PTC; NEC 690.8 OCPD floor is 21.79 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.42 * (1 + (-0.225/100) * (-10 - 25)) = 42.52 V | OCPD = 1.56 * 13.97 = 21.79 A
Inputs from CEC Modules.csv for Thornova Solar TS-BBT54(455): Voc=39.42 V, beta_Voc=-0.225%/C, Isc=13.97 A, STC=455.0 W, Area=1.94 m2.
Result: 14 panels max on 600 V (595.3 V); 18 panels for 8 kW (376 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-BBT54(455)?
Laboratory test ratings recorded for Thornova Solar TS-BBT54(455) (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 455.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 432.4 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.42 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.97 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.9 V / 13.45 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.225 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.45% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Thornova Solar TS-BBT54(455) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (376 sq ft at 8 kW), and estimated Year-1 electric bill offset for Thornova Solar TS-BBT54(455).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.37 kW | 292 sq ft | $1,594 | $2,696 |
| 8 kW Class | 18 | 8.19 kW | 376 sq ft | $2,050 | $3,466 |
| 10 kW Class | 22 | 10.01 kW | 459 sq ft | $2,505 | $4,236 |
How Many Thornova Solar TS-BBT54(455) Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Thornova Solar TS-BBT54(455) (beta_Voc -0.225%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.41 V | 13 panels | 564.3 V | 23 panels |
| -10 C (14 F) | 42.52 V | 14 panels | 595.3 V | 23 panels |
| 0 C (32 F) | 41.64 V | 14 panels | 583.0 V | 24 panels |
| 25 C (77 F STC) | 39.42 V | 15 panels | 591.3 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BBT54(455)?
Closest cross-brand CEC competitors to Thornova Solar TS-BBT54(455) matched near 455.0 W STC and 39.42 V Voc, led by Aptos Solar Technology LLC DNA-108-BFN10-455W-DG.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-BFN10-455W-DG Aptos Solar Technology LLC |
455.0 W | Tie (0 W) | 39.7 V | 23.45% | 95.1% |
| CertainTeed CTTC455HC12-08 CertainTeed |
455.0 W | Tie (0 W) | 39.0 V | 23.33% | 94.9% |
| CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT450-108TNB10 CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET |
450.0 W | -5.0 W | 39.53 V | 23.08% | 96.1% |
| ES Foundry Corp ES-DN8-H54B-450 ES Foundry Corp |
450.0 W | -5.0 W | 39.54 V | 23.11% | 95.2% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BBT54(455)?
Evaluate Thornova Solar TS-BBT54(455) (455.0 W STC, 39.42 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BBT54(455) reaches 43.41 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 376 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (376 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BBT54(455) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-BBT54(455) 8 kW Residential Fit
Needs 18 modules (376 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Aptos Solar Technology LLC DNA-108-BFN10-455W-DG.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 432.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-BBT54(455) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-BBT54(455)?
Multiplying Thornova Solar TS-BBT54(455)'s 13.97 A short-circuit current by 1.56 equals 21.79 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Thornova Solar TS-BBT54(455) pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 42.52 V cold Voc at 14 F and handles 13.97 A Isc; string inverters cap Thornova Solar TS-BBT54(455) at 14 panels on 600 V.
Is Thornova Solar TS-BBT54(455) eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-BBT54(455) rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)