Thornova Solar TS-BB72(535) is a 535.0 W STC (498.4 W PTC) Mono-c-Si solar module ranking #3,537 of 21,677 CEC listings (top 17.5%; higher than 82.5% of peers). It delivers 20.74% efficiency, 49.34 V Voc at 25 C, and 53.86 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 535.0 W
- PTC Wattage
- 498.4 W
- Voc @ 25C
- 49.34 V
- Efficiency
- 20.74%
How Does Thornova Solar TS-BB72(535) Compare Against Peer CEC Listings?
Solar engineering breakdown for Thornova Solar TS-BB72(535): PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Thornova Solar and peers, Thornova Solar TS-BB72(535) stands 125.0 W above the 410.0 W Mono-c-Si median and strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677). Sizing 6 kW (12 panels) to 10 kW (19 panels) yields $1,607-$2,543/yr in baseline US bill offset. Higher 49.34 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does Thornova Solar TS-BB72(535) Fall Across Listed CEC Models?
Distribution marker showing Thornova Solar TS-BB72(535) (535.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Thornova Solar TS-BB72(535)?
Dataset percentiles tracking Thornova Solar TS-BB72(535) power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Thornova Solar TS-BB72(535)?
Benchmark highlights for Thornova Solar TS-BB72(535) covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 17.5% STC Output
535.0 W STC (+150.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.74% Aperture Efficiency
Power density 207.4 W/m2 (0.83 percentage points above 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.86 V at -10 C (592.5 V string) and 55.16 V at -20 C (10 max).
15 Panels = 8,025 W STC
Occupies 38.7 m2 (417 sq ft) producing 7,476 W PTC; NEC 690.8 OCPD floor is 21.51 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.34 * (1 + (-0.262/100) * (-10 - 25)) = 53.86 V | OCPD = 1.56 * 13.79 = 21.51 A
Inputs from CEC Modules.csv for Thornova Solar TS-BB72(535): Voc=49.34 V, beta_Voc=-0.262%/C, Isc=13.79 A, STC=535.0 W, Area=2.58 m2.
Result: 11 panels max on 600 V (592.5 V); 15 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-BB72(535)?
Official CEC datasheet figures for Thornova Solar TS-BB72(535) (Mono-c-Si) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 535.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 498.4 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.34 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.79 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.66 V / 13.16 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.262 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.74% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Thornova Solar TS-BB72(535) Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Thornova Solar TS-BB72(535) modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.42 kW | 333 sq ft | $1,607 | $2,717 |
| 8 kW Class | 15 | 8.03 kW | 417 sq ft | $2,010 | $3,398 |
| 10 kW Class | 19 | 10.16 kW | 528 sq ft | $2,543 | $4,300 |
How Many Thornova Solar TS-BB72(535) Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Thornova Solar TS-BB72(535) (53.86 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.16 V | 10 panels | 551.6 V | 18 panels |
| -10 C (14 F) | 53.86 V | 11 panels | 592.5 V | 18 panels |
| 0 C (32 F) | 52.57 V | 11 panels | 578.3 V | 19 panels |
| 25 C (77 F STC) | 49.34 V | 12 panels | 592.1 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BB72(535)?
Competing CEC solar panels closest to Thornova Solar TS-BB72(535) in nameplate wattage and Voc, starting with Allesun Industries Inc Allesun-535-72IIMBG.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Allesun Industries Inc Allesun-535-72IIMBG Allesun Industries Inc |
535.0 W | Tie (0 W) | 49.34 V | 20.9% | 94.0% |
| Aptos Solar Technology LLC DNA-144-MF10-535W Aptos Solar Technology LLC |
535.0 W | Tie (0 W) | 49.34 V | 20.9% | 93.7% |
| Allesun Industries Inc AS-535-72IIMB Allesun Industries Inc |
535.0 W | Tie (0 W) | 49.35 V | 20.9% | 94.1% |
| GermanSolar USA Inc GSM-535W-HC GermanSolar USA Inc |
535.0 W | Tie (0 W) | 49.35 V | 22.48% | 94.6% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BB72(535)?
Evaluate Thornova Solar TS-BB72(535) (535.0 W STC, 49.34 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BB72(535) reaches 55.16 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BB72(535) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-BB72(535) 8 kW Residential Fit
Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,010/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Allesun Industries Inc Allesun-535-72IIMBG.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 498.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-BB72(535) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-BB72(535)?
Multiplying Thornova Solar TS-BB72(535)'s 13.79 A short-circuit current by 1.56 equals 21.51 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Thornova Solar TS-BB72(535) pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.86 V cold Voc at 14 F and handles 13.79 A Isc; string inverters cap Thornova Solar TS-BB72(535) at 11 panels on 600 V.
Is Thornova Solar TS-BB72(535) eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-BB72(535) rely on utility bill offset (~$2,010/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)