Thornova Solar TS-BB60(440) is a 440.0 W STC (415.1 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 20.56% efficiency, 41.18 V Voc at 25 C, and 44.52 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 440.0 W
- PTC Wattage
- 415.1 W
- Voc @ 25C
- 41.18 V
- Efficiency
- 20.56%
How Does Thornova Solar TS-BB60(440) Compare Against Peer CEC Listings?
Solar engineering breakdown for Thornova Solar TS-BB60(440): PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Thornova Solar and peers, Thornova Solar TS-BB60(440) stands 30.0 W above the 410.0 W Mono-c-Si median and strong 94.3% PTC-to-STC heat retention (#3,231 of 21,677). Sizing 6 kW (14 panels) to 10 kW (23 panels) yields $1,542-$2,533/yr in baseline US bill offset. Mid-range 41.18 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.
Where Does Thornova Solar TS-BB60(440) Fall Across Listed CEC Models?
Distribution marker showing Thornova Solar TS-BB60(440) (440.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Thornova Solar TS-BB60(440)?
Dataset percentiles tracking Thornova Solar TS-BB60(440) power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Thornova Solar TS-BB60(440)?
Benchmark highlights for Thornova Solar TS-BB60(440) covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 31.6% STC Output
440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.56% Aperture Efficiency
Power density 205.6 W/m2 (0.65 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.52 V at -10 C (578.8 V string) and 45.48 V at -20 C (13 max).
19 Panels = 8,360 W STC
Occupies 40.7 m2 (438 sq ft) producing 7,887 W PTC; NEC 690.8 OCPD floor is 20.86 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.18 * (1 + (-0.232/100) * (-10 - 25)) = 44.52 V | OCPD = 1.56 * 13.37 = 20.86 A
Inputs from CEC Modules.csv for Thornova Solar TS-BB60(440): Voc=41.18 V, beta_Voc=-0.232%/C, Isc=13.37 A, STC=440.0 W, Area=2.14 m2.
Result: 13 panels max on 600 V (578.8 V); 19 panels for 8 kW (438 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-BB60(440)?
Official CEC datasheet figures for Thornova Solar TS-BB60(440) (Mono-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 415.1 W (94.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.18 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.37 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.33 V / 12.82 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.232 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.56% (2.14 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Thornova Solar TS-BB60(440) Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Thornova Solar TS-BB60(440) modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.16 kW | 322 sq ft | $1,542 | $2,607 |
| 8 kW Class | 19 | 8.36 kW | 438 sq ft | $2,092 | $3,538 |
| 10 kW Class | 23 | 10.12 kW | 530 sq ft | $2,533 | $4,283 |
How Many Thornova Solar TS-BB60(440) Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Thornova Solar TS-BB60(440) (44.52 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.48 V | 13 panels | 591.2 V | 21 panels |
| -10 C (14 F) | 44.52 V | 13 panels | 578.8 V | 22 panels |
| 0 C (32 F) | 43.57 V | 13 panels | 566.4 V | 22 panels |
| 25 C (77 F STC) | 41.18 V | 14 panels | 576.5 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BB60(440)?
Competing CEC solar panels closest to Thornova Solar TS-BB60(440) in nameplate wattage and Voc, starting with Aptos Solar Technology LLC DNA-120-BF10-440W-USAptos1.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-120-BF10-440W-USAptos1 Aptos Solar Technology LLC |
440.0 W | Tie (0 W) | 41.18 V | 20.56% | 94.3% |
| Aptos Solar Technology LLC DNA-120-BF10-440W-USAptos2 Aptos Solar Technology LLC |
440.0 W | Tie (0 W) | 41.2 V | 20.56% | 94.3% |
| Aptos Solar Technology LLC DNA-120-BF10-440W Aptos Solar Technology LLC |
440.0 W | Tie (0 W) | 41.11 V | 20.56% | 92.6% |
| Dehui Solar Power (Vietnam) CoLtd DH-M160T 440W Dehui Solar Power (Vietnam) CoLtd |
440.0 W | Tie (0 W) | 41.11 V | 20.56% | 92.6% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BB60(440)?
Evaluate Thornova Solar TS-BB60(440) (440.0 W STC, 41.18 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BB60(440) reaches 45.48 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 438 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (438 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BB60(440) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-BB60(440) 8 kW Residential Fit
Needs 19 modules (438 sq ft) with a 25 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Aptos Solar Technology LLC DNA-120-BF10-440W-USAptos1.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 415.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-BB60(440) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-BB60(440)?
Multiplying Thornova Solar TS-BB60(440)'s 13.37 A short-circuit current by 1.56 equals 20.86 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Thornova Solar TS-BB60(440) pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 44.52 V cold Voc at 14 F and handles 13.37 A Isc; string inverters cap Thornova Solar TS-BB60(440) at 13 panels on 600 V.
Is Thornova Solar TS-BB60(440) eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-BB60(440) rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)