Suzhou Talesun Solar Technologies Co Ltd TP672P-310 is a 310.0 W STC (281.4 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.98% efficiency, 45.2 V Voc at 25 C, and 50.37 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 310.0 W
- PTC Wattage
- 281.4 W
- Voc @ 25C
- 45.2 V
- Efficiency
- 15.98%
How Does Suzhou Talesun Solar Technologies Co Ltd TP672P-310 Compare Against Peer CEC Listings?
Solar engineering breakdown for Suzhou Talesun Solar Technologies Co Ltd TP672P-310: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 1,407 Multi-c-Si listings from Suzhou Talesun Solar Technologies Co Ltd and peers, Suzhou Talesun Solar Technologies Co Ltd TP672P-310 stands 31.2 W above the 278.8 W Multi-c-Si median and typical 90.8% PTC-to-STC thermal output (281.4 W real-world rating). Sizing 6 kW (20 panels) to 10 kW (33 panels) yields $1,552-$2,560/yr in baseline US bill offset. Mid-range 45.2 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.
Where Does Suzhou Talesun Solar Technologies Co Ltd TP672P-310 Fall Across Listed CEC Models?
Distribution marker showing Suzhou Talesun Solar Technologies Co Ltd TP672P-310 (310.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Suzhou Talesun Solar Technologies Co Ltd TP672P-310?
Dataset percentiles tracking Suzhou Talesun Solar Technologies Co Ltd TP672P-310 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Suzhou Talesun Solar Technologies Co Ltd TP672P-310?
Benchmark highlights for Suzhou Talesun Solar Technologies Co Ltd TP672P-310 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
310.0 W STC · Higher Than 25.6%
310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.98% Aperture Efficiency
Power density 159.8 W/m2 (3.93 percentage points below 19.91% CEC median). PTC/STC ratio: 90.8% (rank #17,104).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.37 V at -10 C (554.1 V string) and 51.85 V at -20 C (11 max).
26 Panels = 8,060 W STC
Occupies 50.4 m2 (543 sq ft) producing 7,316 W PTC; NEC 690.8 OCPD floor is 14.18 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.2 * (1 + (-0.327/100) * (-10 - 25)) = 50.37 V | OCPD = 1.56 * 9.09 = 14.18 A
Inputs from CEC Modules.csv for Suzhou Talesun Solar Technologies Co Ltd TP672P-310: Voc=45.2 V, beta_Voc=-0.327%/C, Isc=9.09 A, STC=310.0 W, Area=1.94 m2.
Result: 11 panels max on 600 V (554.1 V); 26 panels for 8 kW (543 sq ft).
What Are the Published CEC Specifications for Suzhou Talesun Solar Technologies Co Ltd TP672P-310?
Official CEC datasheet figures for Suzhou Talesun Solar Technologies Co Ltd TP672P-310 (Multi-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 281.4 W (90.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.09 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.4 V / 8.52 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.327 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.98% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Suzhou Talesun Solar Technologies Co Ltd TP672P-310 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Suzhou Talesun Solar Technologies Co Ltd TP672P-310 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.2 kW | 418 sq ft | $1,552 | $2,624 |
| 8 kW Class | 26 | 8.06 kW | 543 sq ft | $2,017 | $3,411 |
| 10 kW Class | 33 | 10.23 kW | 689 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This Suzhou Talesun Solar Technologies Co Ltd Series?
Consolidated Suzhou Talesun Solar Technologies Co Ltd wattage variants sharing the Suzhou Talesun Solar Technologies Co Ltd TP672P-310 mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Suzhou Talesun Solar Technologies Co Ltd TP672P-300 | 300.0 W | 270.3 W | 45.0 V | 36.1 V | 15.46% |
| Suzhou Talesun Solar Technologies Co Ltd TP672P-305 | 305.0 W | 276.7 W | 45.0 V | 36.2 V | 15.72% |
| Suzhou Talesun Solar Technologies Co Ltd TP672P-310 | 310.0 W | 281.4 W | 45.2 V | 36.4 V | 15.98% |
| Suzhou Talesun Solar Technologies Co Ltd TP672P-315 | 315.0 W | 286.2 W | 45.2 V | 36.8 V | 16.23% |
| Suzhou Talesun Solar Technologies Co Ltd TP672P-320 | 320.0 W | 290.8 W | 45.5 V | 37.1 V | 16.49% |
How Many Suzhou Talesun Solar Technologies Co Ltd TP672P-310 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Suzhou Talesun Solar Technologies Co Ltd TP672P-310 (50.37 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.85 V | 11 panels | 570.4 V | 19 panels |
| -10 C (14 F) | 50.37 V | 11 panels | 554.1 V | 19 panels |
| 0 C (32 F) | 48.9 V | 12 panels | 586.8 V | 20 panels |
| 25 C (77 F STC) | 45.2 V | 13 panels | 587.6 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Suzhou Talesun Solar Technologies Co Ltd TP672P-310?
Competing CEC solar panels closest to Suzhou Talesun Solar Technologies Co Ltd TP672P-310 in nameplate wattage and Voc, starting with Advance Power API-P310.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Advance Power API-P310 Advance Power |
310.0 W | Tie (0 W) | 45.22 V | 15.89% | 89.5% |
| Auxin Solar AXN6P612T310 Auxin Solar |
310.0 W | Tie (0 W) | 45.22 V | 15.89% | 89.5% |
| Centrosolar America DP72 310 Centrosolar America |
310.0 W | Tie (0 W) | 45.18 V | 15.94% | 90.2% |
| AXITEC AC-310P/156-72S AXITEC |
310.0 W | Tie (0 W) | 45.05 V | 16.01% | 89.0% |
What Are the Design Limits and Best-Fit Uses for Suzhou Talesun Solar Technologies Co Ltd TP672P-310?
Evaluate Suzhou Talesun Solar Technologies Co Ltd TP672P-310 (310.0 W STC, 45.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Suzhou Talesun Solar Technologies Co Ltd TP672P-310 reaches 51.85 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (543 sq ft).
- 2026 tax credit baseline: cash residential installs of Suzhou Talesun Solar Technologies Co Ltd TP672P-310 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Suzhou Talesun Solar Technologies Co Ltd TP672P-310 8 kW Residential Fit
Needs 26 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-P310.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 281.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Suzhou Talesun Solar Technologies Co Ltd TP672P-310 by Suzhou Talesun Solar Technologies Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Suzhou Talesun Solar Technologies Co Ltd TP672P-310?
Multiplying Suzhou Talesun Solar Technologies Co Ltd TP672P-310's 9.09 A short-circuit current by 1.56 equals 14.18 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Suzhou Talesun Solar Technologies Co Ltd TP672P-310 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 50.37 V cold Voc at 14 F and handles 9.09 A Isc; string inverters cap Suzhou Talesun Solar Technologies Co Ltd TP672P-310 at 11 panels on 600 V.
Is Suzhou Talesun Solar Technologies Co Ltd TP672P-310 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Suzhou Talesun Solar Technologies Co Ltd TP672P-310 rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)