Manufacturer: Suntech Power Registry: CEC Verified Engineering Specification

Suntech Power STP285S-20/Wem is a 285.0 W STC (261.2 W PTC) Mono-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 17.52% efficiency, 39.6 V Voc at 25 C, and 44.16 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
285.0 W
PTC Wattage
261.2 W
Voc @ 25C
39.6 V
Efficiency
17.52%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Suntech Power STP285S-20/Wem Compare Against Peer CEC Listings?

Solar engineering breakdown for Suntech Power STP285S-20/Wem: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Suntech Power and peers, Suntech Power STP285S-20/Wem stands 125.0 W below the 410.0 W Mono-c-Si median and strong 91.6% PTC-to-STC heat retention (#15,328 of 21,677). Sizing 6 kW (22 panels) to 10 kW (36 panels) yields $1,569-$2,568/yr in baseline US bill offset. Lower 39.6 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.

Where Does Suntech Power STP285S-20/Wem Fall Across Listed CEC Models?

Distribution marker showing Suntech Power STP285S-20/Wem (285.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Suntech Power STP285S-20/Wem (285.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSuntech Power STP2: 285.0 W

What Dataset Percentiles Define Suntech Power STP285S-20/Wem?

Dataset percentiles tracking Suntech Power STP285S-20/Wem power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Suntech Power STP285S-20/Wem Engineering BenchmarksPercentile comparison of Suntech Power STP285S-20/Wem wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage285.0 WPTC/STC Retention91.6%Module Efficiency17.52%

What Do the Dataset Ranks Show for Suntech Power STP285S-20/Wem?

Benchmark highlights for Suntech Power STP285S-20/Wem covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #17,598 / 21,677

285.0 W STC · Higher Than 17.3%

285.0 W STC (-100.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #15,748

17.52% Aperture Efficiency

Power density 175.2 W/m2 (2.39 percentage points below 19.91% CEC median). PTC/STC ratio: 91.6% (rank #15,328).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.16 V at -10 C (574.1 V string) and 45.46 V at -20 C (13 max).

8 kW Reference Array

29 Panels = 8,265 W STC

Occupies 47.2 m2 (508 sq ft) producing 7,575 W PTC; NEC 690.8 OCPD floor is 14.79 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.6 * (1 + (-0.329/100) * (-10 - 25)) = 44.16 V | OCPD = 1.56 * 9.48 = 14.79 A

Inputs from CEC Modules.csv for Suntech Power STP285S-20/Wem: Voc=39.6 V, beta_Voc=-0.329%/C, Isc=9.48 A, STC=285.0 W, Area=1.627 m2.

Result: 13 panels max on 600 V (574.1 V); 29 panels for 8 kW (508 sq ft).

What Are the Published CEC Specifications for Suntech Power STP285S-20/Wem?

Official CEC datasheet figures for Suntech Power STP285S-20/Wem (Mono-c-Si) used in utility interconnection and permit reviews. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for Suntech Power STP285S-20/Wem.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 285.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 261.2 W (91.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.48 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.6 V / 9.02 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.329 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.52% (1.627 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Suntech Power STP285S-20/Wem Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Suntech Power STP285S-20/Wem modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.27 kW 385 sq ft $1,569 $2,654
8 kW Class 29 8.27 kW 508 sq ft $2,070 $3,500
10 kW Class 36 10.26 kW 630 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Suntech Power Series?

Consolidated Suntech Power wattage variants sharing the Suntech Power STP285S-20/Wem mechanical and cell layout. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the Suntech Power STP285S-20/Wem wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Suntech Power STP275S-20/Wem 275.0 W 251.8 W 38.5 V 31.1 V 16.9%
Suntech Power STP280S-20/Wem 280.0 W 256.5 W 39.4 V 31.5 V 17.21%
Suntech Power STP285S-20/Wem 285.0 W 261.2 W 39.6 V 31.6 V 17.52%
Suntech Power STP290S-20/Wem 290.0 W 265.9 W 39.8 V 31.7 V 17.83%

How Many Suntech Power STP285S-20/Wem Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Suntech Power STP285S-20/Wem (44.16 V at 14 F).

Computed from Voc=39.6V and beta_Voc=-0.329%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.46 V 13 panels 591.0 V 21 panels
-10 C (14 F) 44.16 V 13 panels 574.1 V 22 panels
0 C (32 F) 42.86 V 13 panels 557.2 V 23 panels
25 C (77 F STC) 39.6 V 15 panels 594.0 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to Suntech Power STP285S-20/Wem?

Competing CEC solar panels closest to Suntech Power STP285S-20/Wem in nameplate wattage and Voc, starting with Auxin Solar AXN6P610T285.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6P610T285
Auxin Solar
285.0 W Tie (0 W) 39.57 V 17.52% 90.4%
Ablytek 6MN6A285
Ablytek
285.0 W Tie (0 W) 39.65 V 17.52% 89.8%
GermanSolar USA GSM6-60-285W
GermanSolar USA
285.0 W Tie (0 W) 39.65 V 17.52% 89.8%
Auxin Solar AXN6M610T285
Auxin Solar
285.0 W Tie (0 W) 39.43 V 17.52% 91.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Suntech Power STP285S-20/Wem?

Evaluate Suntech Power STP285S-20/Wem (285.0 W STC, 39.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Suntech Power STP285S-20/Wem reaches 45.46 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 29 panels for an 8 kW build require 508 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (508 sq ft).
  • 2026 tax credit baseline: cash residential installs of Suntech Power STP285S-20/Wem carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Suntech Power STP285S-20/Wem 8 kW Residential Fit

Needs 29 modules (508 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Auxin Solar AXN6P610T285.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 261.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Suntech Power STP285S-20/Wem by Suntech Power grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Suntech Power STP285S-20/Wem?

Multiplying Suntech Power STP285S-20/Wem's 9.48 A short-circuit current by 1.56 equals 14.79 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Suntech Power STP285S-20/Wem pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.16 V cold Voc at 14 F and handles 9.48 A Isc; string inverters cap Suntech Power STP285S-20/Wem at 13 panels on 600 V.

Is Suntech Power STP285S-20/Wem eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Suntech Power STP285S-20/Wem rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.