Auxin Solar AXN6M610T285 is a 285.0 W STC (261.4 W PTC) Mono-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 17.52% efficiency, 39.43 V Voc at 25 C, and 43.57 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 285.0 W
- PTC Wattage
- 261.4 W
- Voc @ 25C
- 39.43 V
- Efficiency
- 17.52%
How Does Auxin Solar AXN6M610T285 Compare Against Peer CEC Listings?
Engineering position of Auxin Solar AXN6M610T285 (285.0 W STC) vs. Bluesun Solar Energy Tech CoLtd BSM285M-60 across 5,889 CEC Mono-c-Si solar modules.
Built with 60 Mono-c-Si cells, Auxin Solar AXN6M610T285 pairs strong 91.7% PTC-to-STC heat retention (#15,053 of 21,677) with 39.43 V nominal Voc. An 8 kW residential build (8,265 W DC, 7,581 W PTC) saves ~$2,070/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Bluesun Solar Energy Tech CoLtd BSM285M-60 offers a 285.0 W alternative.
Where Does Auxin Solar AXN6M610T285 Fall Across Listed CEC Models?
Plots Auxin Solar AXN6M610T285 at 285.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Auxin Solar AXN6M610T285?
Benchmarks Auxin Solar AXN6M610T285 on STC wattage, thermal PTC/STC retention, and 17.52 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Auxin Solar AXN6M610T285?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Auxin Solar AXN6M610T285 by Auxin Solar.
285.0 W STC · Higher Than 17.3%
285.0 W STC (-100.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.52% Aperture Efficiency
Power density 175.2 W/m2 (2.39 percentage points below 19.91% CEC median). PTC/STC ratio: 91.7% (rank #15,053).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.57 V at -10 C (566.4 V string) and 44.75 V at -20 C (13 max).
29 Panels = 8,265 W STC
Occupies 47.2 m2 (508 sq ft) producing 7,581 W PTC; NEC 690.8 OCPD floor is 14.79 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.43 * (1 + (-0.3/100) * (-10 - 25)) = 43.57 V | OCPD = 1.56 * 9.48 = 14.79 A
Inputs from CEC Modules.csv for Auxin Solar AXN6M610T285: Voc=39.43 V, beta_Voc=-0.3%/C, Isc=9.48 A, STC=285.0 W, Area=1.627 m2.
Result: 13 panels max on 600 V (566.4 V); 29 panels for 8 kW (508 sq ft).
What Are the Published CEC Specifications for Auxin Solar AXN6M610T285?
Laboratory test ratings recorded for Auxin Solar AXN6M610T285 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 285.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 261.4 W (91.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.43 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.48 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.76 V / 8.97 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.3 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.52% (1.627 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Auxin Solar AXN6M610T285 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (508 sq ft at 8 kW), and estimated Year-1 electric bill offset for Auxin Solar AXN6M610T285.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.27 kW | 385 sq ft | $1,569 | $2,654 |
| 8 kW Class | 29 | 8.27 kW | 508 sq ft | $2,070 | $3,500 |
| 10 kW Class | 36 | 10.26 kW | 630 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Auxin Solar Series?
Sibling wattage bins and frame colors grouped with Auxin Solar AXN6M610T285 under Auxin Solar to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Auxin Solar AXN6M610T275 | 275.0 W | 252.0 W | 38.77 V | 31.29 V | 16.9% |
| Auxin Solar AXN6M610T280 | 280.0 W | 256.7 W | 39.1 V | 31.53 V | 17.21% |
| Auxin Solar AXN6M610T285 | 285.0 W | 261.4 W | 39.43 V | 31.76 V | 17.52% |
| Auxin Solar AXN6M610T290 | 290.0 W | 266.1 W | 39.77 V | 32.0 V | 17.83% |
| Auxin Solar AXN6M610T295 | 295.0 W | 270.4 W | 40.11 V | 32.24 V | 18.13% |
How Many Auxin Solar AXN6M610T285 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Auxin Solar AXN6M610T285 (beta_Voc -0.3%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.75 V | 13 panels | 581.8 V | 22 panels |
| -10 C (14 F) | 43.57 V | 13 panels | 566.4 V | 22 panels |
| 0 C (32 F) | 42.39 V | 14 panels | 593.5 V | 23 panels |
| 25 C (77 F STC) | 39.43 V | 15 panels | 591.5 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXN6M610T285?
Closest cross-brand CEC competitors to Auxin Solar AXN6M610T285 matched near 285.0 W STC and 39.43 V Voc, led by Bluesun Solar Energy Tech CoLtd BSM285M-60.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Bluesun Solar Energy Tech CoLtd BSM285M-60 Bluesun Solar Energy Tech CoLtd |
285.0 W | Tie (0 W) | 39.25 V | 17.52% | 90.1% |
| DuCal Solar Technology LLC DST285M-60 DuCal Solar Technology LLC |
285.0 W | Tie (0 W) | 39.25 V | 17.52% | 90.1% |
| Ablytek 6MN6A285 Ablytek |
285.0 W | Tie (0 W) | 39.65 V | 17.52% | 89.8% |
| GermanSolar USA GSM6-60-285W GermanSolar USA |
285.0 W | Tie (0 W) | 39.65 V | 17.52% | 89.8% |
What Are the Design Limits and Best-Fit Uses for Auxin Solar AXN6M610T285?
Evaluate Auxin Solar AXN6M610T285 (285.0 W STC, 39.43 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXN6M610T285 reaches 44.75 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 29 panels for an 8 kW build require 508 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (508 sq ft).
- 2026 tax credit baseline: cash residential installs of Auxin Solar AXN6M610T285 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Auxin Solar AXN6M610T285 8 kW Residential Fit
Needs 29 modules (508 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM285M-60.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 261.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Auxin Solar AXN6M610T285 by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Auxin Solar AXN6M610T285?
Multiplying Auxin Solar AXN6M610T285's 9.48 A short-circuit current by 1.56 equals 14.79 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Auxin Solar AXN6M610T285 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 43.57 V cold Voc at 14 F and handles 9.48 A Isc; string inverters cap Auxin Solar AXN6M610T285 at 13 panels on 600 V.
Is Auxin Solar AXN6M610T285 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Auxin Solar AXN6M610T285 rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)