Suntech Power STP285-24/Ve — CEC Solar Module Specifications

Manufacturer: Suntech Power Registry: CEC Verified Engineering Specification

Suntech Power STP285-24/Ve is a 285.0 W STC (258.6 W PTC) Multi-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 14.69% efficiency, 44.8 V Voc at 25 C, and 49.71 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
285.0 W
PTC Wattage
258.6 W
Voc @ 25C
44.8 V
Efficiency
14.69%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Suntech Power STP285-24/Ve Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Suntech Power STP285-24/Ve (Multi-c-Si) residential solar systems.

Homeowners evaluating Suntech Power STP285-24/Ve need 22 panels for 6 kW or 29 panels (606 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (606 sq ft). Under NEC 690.7(A), beta_Voc (-0.313%/C) pushes open-circuit voltage to 49.71 V at 14 F and 51.11 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Suntech Power STP285-24/Ve Fall Across Listed CEC Models?

Comparison of Suntech Power STP285-24/Ve (285.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Suntech Power STP285-24/Ve (285.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSuntech Power STP2: 285.0 W

What Dataset Percentiles Define Suntech Power STP285-24/Ve?

Relative ranking of Suntech Power STP285-24/Ve across nameplate watts, 90.7% PTC thermal ratio, and module aperture efficiency.

Suntech Power STP285-24/Ve Engineering BenchmarksPercentile comparison of Suntech Power STP285-24/Ve wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage285.0 WPTC/STC Retention90.7%Module Efficiency14.69%

What Do the Dataset Ranks Show for Suntech Power STP285-24/Ve?

Summary of Suntech Power STP285-24/Ve output rank, 8 kW array size (29 panels), efficiency rating, and 600 V string limit.

Rank #17,598 / 21,677

285.0 W STC · Higher Than 17.3%

285.0 W STC (-100.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,164

14.69% Aperture Efficiency

Power density 146.9 W/m2 (5.22 percentage points below 19.91% CEC median). PTC/STC ratio: 90.7% (rank #17,330).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.71 V at -10 C (596.5 V string) and 51.11 V at -20 C (11 max).

8 kW Reference Array

29 Panels = 8,265 W STC

Occupies 56.3 m2 (606 sq ft) producing 7,499 W PTC; NEC 690.8 OCPD floor is 13.06 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.8 * (1 + (-0.313/100) * (-10 - 25)) = 49.71 V | OCPD = 1.56 * 8.37 = 13.06 A

Inputs from CEC Modules.csv for Suntech Power STP285-24/Ve: Voc=44.8 V, beta_Voc=-0.313%/C, Isc=8.37 A, STC=285.0 W, Area=1.94 m2.

Result: 12 panels max on 600 V (596.5 V); 29 panels for 8 kW (606 sq ft).

What Are the Published CEC Specifications for Suntech Power STP285-24/Ve?

Complete CEC test sheet for Suntech Power STP285-24/Ve including Isc (8.37 A), Voc (44.8 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Suntech Power STP285-24/Ve.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 285.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 258.6 W (90.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.37 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 35.8 V / 7.95 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.313 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.69% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Suntech Power STP285-24/Ve Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Suntech Power STP285-24/Ve.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.27 kW 459 sq ft $1,569 $2,654
8 kW Class 29 8.27 kW 606 sq ft $2,070 $3,500
10 kW Class 36 10.26 kW 752 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Suntech Power Series?

Related Suntech Power power steps and black/silver trims consolidated into this Suntech Power STP285-24/Ve series guide.

Sibling CEC listings grouped into the Suntech Power STP285-24/Ve wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Suntech Power STP275-24/Ve 275.0 W 249.3 W 44.7 V 35.1 V 14.17%
Suntech Power STP280-24/Ve 280.0 W 254.0 W 44.8 V 35.2 V 14.43%
Suntech Power STP285-24/Ve 285.0 W 258.6 W 44.8 V 35.8 V 14.69%
Suntech Power STP290-24/Ve 290.0 W 263.3 W 44.8 V 36.5 V 14.95%
Suntech Power STP295-24/Ve 295.0 W 267.2 W 44.9 V 36.8 V 15.2%

How Many Suntech Power STP285-24/Ve Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Suntech Power STP285-24/Ve (44.8 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=44.8V and beta_Voc=-0.313%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.11 V 11 panels 562.2 V 19 panels
-10 C (14 F) 49.71 V 12 panels 596.5 V 20 panels
0 C (32 F) 48.31 V 12 panels 579.7 V 20 panels
25 C (77 F STC) 44.8 V 13 panels 582.4 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Suntech Power STP285-24/Ve?

Four comparable CEC modules such as Gintung Energy ASEC-285G6S (285.0 W) for side-by-side solar quote checks. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Gintung Energy ASEC-285G6S
Gintung Energy
285.0 W Tie (0 W) 44.69 V 14.57% 89.7%
Gintung Energy ASEC-285G6M
Gintung Energy
285.0 W Tie (0 W) 44.53 V 14.57% 89.5%
AXITEC AC-285P/156-72S
AXITEC
285.0 W Tie (0 W) 44.51 V 14.72% 90.0%
Centrosolar America DP72 285
Centrosolar America
285.0 W Tie (0 W) 44.32 V 14.66% 88.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Suntech Power STP285-24/Ve?

Evaluate Suntech Power STP285-24/Ve (285.0 W STC, 44.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Suntech Power STP285-24/Ve reaches 51.11 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 29 panels for an 8 kW build require 606 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (606 sq ft).
  • 2026 tax credit baseline: cash residential installs of Suntech Power STP285-24/Ve carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Suntech Power STP285-24/Ve 8 kW Residential Fit

Needs 29 modules (606 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Gintung Energy ASEC-285G6S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 258.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Suntech Power STP285-24/Ve by Suntech Power grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Suntech Power STP285-24/Ve PTC wattage (258.6 W) lower than STC (285.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 258.6 W PTC (90.7% retention) across Suntech Power STP285-24/Ve's 1.94 m2 aperture.

Who should skip Suntech Power STP285-24/Ve on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 29 Suntech Power STP285-24/Ve panels (606 sq ft) leave unusable roof gaps vs. Gintung Energy ASEC-285G6S.

What is the 1,000 V commercial string limit for Suntech Power STP285-24/Ve?

On 1,000 V commercial inverters at -10 C (49.71 V cold Voc), Suntech Power STP285-24/Ve fits up to 20 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Suntech Power STP285-24/Ve.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.