Suntech Power STP285-24/Ve is a 285.0 W STC (258.6 W PTC) Multi-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 14.69% efficiency, 44.8 V Voc at 25 C, and 49.71 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 285.0 W
- PTC Wattage
- 258.6 W
- Voc @ 25C
- 44.8 V
- Efficiency
- 14.69%
How Does Suntech Power STP285-24/Ve Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Suntech Power STP285-24/Ve (Multi-c-Si) residential solar systems.
Homeowners evaluating Suntech Power STP285-24/Ve need 22 panels for 6 kW or 29 panels (606 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (606 sq ft). Under NEC 690.7(A), beta_Voc (-0.313%/C) pushes open-circuit voltage to 49.71 V at 14 F and 51.11 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Suntech Power STP285-24/Ve Fall Across Listed CEC Models?
Comparison of Suntech Power STP285-24/Ve (285.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Suntech Power STP285-24/Ve?
Relative ranking of Suntech Power STP285-24/Ve across nameplate watts, 90.7% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Suntech Power STP285-24/Ve?
Summary of Suntech Power STP285-24/Ve output rank, 8 kW array size (29 panels), efficiency rating, and 600 V string limit.
285.0 W STC · Higher Than 17.3%
285.0 W STC (-100.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.69% Aperture Efficiency
Power density 146.9 W/m2 (5.22 percentage points below 19.91% CEC median). PTC/STC ratio: 90.7% (rank #17,330).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 49.71 V at -10 C (596.5 V string) and 51.11 V at -20 C (11 max).
29 Panels = 8,265 W STC
Occupies 56.3 m2 (606 sq ft) producing 7,499 W PTC; NEC 690.8 OCPD floor is 13.06 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.8 * (1 + (-0.313/100) * (-10 - 25)) = 49.71 V | OCPD = 1.56 * 8.37 = 13.06 A
Inputs from CEC Modules.csv for Suntech Power STP285-24/Ve: Voc=44.8 V, beta_Voc=-0.313%/C, Isc=8.37 A, STC=285.0 W, Area=1.94 m2.
Result: 12 panels max on 600 V (596.5 V); 29 panels for 8 kW (606 sq ft).
What Are the Published CEC Specifications for Suntech Power STP285-24/Ve?
Complete CEC test sheet for Suntech Power STP285-24/Ve including Isc (8.37 A), Voc (44.8 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 285.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 258.6 W (90.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.37 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.8 V / 7.95 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.313 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.69% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Suntech Power STP285-24/Ve Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Suntech Power STP285-24/Ve.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.27 kW | 459 sq ft | $1,569 | $2,654 |
| 8 kW Class | 29 | 8.27 kW | 606 sq ft | $2,070 | $3,500 |
| 10 kW Class | 36 | 10.26 kW | 752 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Suntech Power Series?
Related Suntech Power power steps and black/silver trims consolidated into this Suntech Power STP285-24/Ve series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Suntech Power STP275-24/Ve | 275.0 W | 249.3 W | 44.7 V | 35.1 V | 14.17% |
| Suntech Power STP280-24/Ve | 280.0 W | 254.0 W | 44.8 V | 35.2 V | 14.43% |
| Suntech Power STP285-24/Ve | 285.0 W | 258.6 W | 44.8 V | 35.8 V | 14.69% |
| Suntech Power STP290-24/Ve | 290.0 W | 263.3 W | 44.8 V | 36.5 V | 14.95% |
| Suntech Power STP295-24/Ve | 295.0 W | 267.2 W | 44.9 V | 36.8 V | 15.2% |
How Many Suntech Power STP285-24/Ve Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Suntech Power STP285-24/Ve (44.8 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.11 V | 11 panels | 562.2 V | 19 panels |
| -10 C (14 F) | 49.71 V | 12 panels | 596.5 V | 20 panels |
| 0 C (32 F) | 48.31 V | 12 panels | 579.7 V | 20 panels |
| 25 C (77 F STC) | 44.8 V | 13 panels | 582.4 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Suntech Power STP285-24/Ve?
Four comparable CEC modules such as Gintung Energy ASEC-285G6S (285.0 W) for side-by-side solar quote checks. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Gintung Energy ASEC-285G6S Gintung Energy |
285.0 W | Tie (0 W) | 44.69 V | 14.57% | 89.7% |
| Gintung Energy ASEC-285G6M Gintung Energy |
285.0 W | Tie (0 W) | 44.53 V | 14.57% | 89.5% |
| AXITEC AC-285P/156-72S AXITEC |
285.0 W | Tie (0 W) | 44.51 V | 14.72% | 90.0% |
| Centrosolar America DP72 285 Centrosolar America |
285.0 W | Tie (0 W) | 44.32 V | 14.66% | 88.5% |
What Are the Design Limits and Best-Fit Uses for Suntech Power STP285-24/Ve?
Evaluate Suntech Power STP285-24/Ve (285.0 W STC, 44.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Suntech Power STP285-24/Ve reaches 51.11 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 29 panels for an 8 kW build require 606 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (606 sq ft).
- 2026 tax credit baseline: cash residential installs of Suntech Power STP285-24/Ve carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Suntech Power STP285-24/Ve 8 kW Residential Fit
Needs 29 modules (606 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Gintung Energy ASEC-285G6S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 258.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Suntech Power STP285-24/Ve by Suntech Power grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Suntech Power STP285-24/Ve PTC wattage (258.6 W) lower than STC (285.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 258.6 W PTC (90.7% retention) across Suntech Power STP285-24/Ve's 1.94 m2 aperture.
Who should skip Suntech Power STP285-24/Ve on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 29 Suntech Power STP285-24/Ve panels (606 sq ft) leave unusable roof gaps vs. Gintung Energy ASEC-285G6S.
What is the 1,000 V commercial string limit for Suntech Power STP285-24/Ve?
On 1,000 V commercial inverters at -10 C (49.71 V cold Voc), Suntech Power STP285-24/Ve fits up to 20 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Suntech Power STP285-24/Ve.