Suntech Power STP235-20/Wde is a 235.0 W STC (213.9 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 14.24% efficiency, 37.0 V Voc at 25 C, and 41.4 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 235.0 W
- PTC Wattage
- 213.9 W
- Voc @ 25C
- 37.0 V
- Efficiency
- 14.24%
How Does Suntech Power STP235-20/Wde Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Suntech Power STP235-20/Wde (Multi-c-Si) residential solar systems.
Suntech Power STP235-20/Wde delivers 142.4 W/m2 (5.67 percentage points below 19.91% CEC median) and typical 91.0% PTC-to-STC thermal output (213.9 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (622 sq ft). At -4 F (-20 C), string voltage climbs to 42.66 V per unit, capping 600 V circuits at 14 panels. Compare specs directly with Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q (235.0 W).
Where Does Suntech Power STP235-20/Wde Fall Across Listed CEC Models?
Comparison of Suntech Power STP235-20/Wde (235.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Suntech Power STP235-20/Wde?
Relative ranking of Suntech Power STP235-20/Wde across nameplate watts, 91.0% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Suntech Power STP235-20/Wde?
Summary of Suntech Power STP235-20/Wde output rank, 8 kW array size (35 panels), efficiency rating, and 600 V string limit.
235.0 W STC · Higher Than 5.4%
235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.24% Aperture Efficiency
Power density 142.4 W/m2 (5.67 percentage points below 19.91% CEC median). PTC/STC ratio: 91.0% (rank #16,685).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.4 V at -10 C (579.6 V string) and 42.66 V at -20 C (14 max).
35 Panels = 8,225 W STC
Occupies 57.8 m2 (622 sq ft) producing 7,486 W PTC; NEC 690.8 OCPD floor is 13.03 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.0 * (1 + (-0.34/100) * (-10 - 25)) = 41.4 V | OCPD = 1.56 * 8.35 = 13.03 A
Inputs from CEC Modules.csv for Suntech Power STP235-20/Wde: Voc=37.0 V, beta_Voc=-0.34%/C, Isc=8.35 A, STC=235.0 W, Area=1.65 m2.
Result: 14 panels max on 600 V (579.6 V); 35 panels for 8 kW (622 sq ft).
What Are the Published CEC Specifications for Suntech Power STP235-20/Wde?
Complete CEC test sheet for Suntech Power STP235-20/Wde including Isc (8.35 A), Voc (37.0 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 235.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 213.9 W (91.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.35 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.2 V / 7.79 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.34 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.24% (1.65 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Suntech Power STP235-20/Wde Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Suntech Power STP235-20/Wde.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 26 | 6.11 kW | 462 sq ft | $1,529 | $2,586 |
| 8 kW Class | 35 | 8.22 kW | 622 sq ft | $2,057 | $3,479 |
| 10 kW Class | 43 | 10.11 kW | 764 sq ft | $2,530 | $4,279 |
Which Sibling Wattage & Trim Variants Belong to This Suntech Power Series?
Related Suntech Power power steps and black/silver trims consolidated into this Suntech Power STP235-20/Wde series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Suntech Power STP225-20/Wde | 225.0 W | 203.9 W | 36.7 V | 29.6 V | 13.64% |
| Suntech Power STP230-20/Wde | 230.0 W | 208.6 W | 36.8 V | 29.8 V | 13.94% |
| Suntech Power STP235-20/Wde | 235.0 W | 213.9 W | 37.0 V | 30.2 V | 14.24% |
| Suntech Power STP240-20/Wde | 240.0 W | 218.6 W | 37.2 V | 30.2 V | 14.55% |
| Suntech Power STP245-20/Wde | 245.0 W | 223.3 W | 37.3 V | 30.5 V | 15.06% |
How Many Suntech Power STP235-20/Wde Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Suntech Power STP235-20/Wde (37.0 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.66 V | 14 panels | 597.2 V | 23 panels |
| -10 C (14 F) | 41.4 V | 14 panels | 579.6 V | 24 panels |
| 0 C (32 F) | 40.14 V | 14 panels | 562.0 V | 24 panels |
| 25 C (77 F STC) | 37.0 V | 16 panels | 592.0 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to Suntech Power STP235-20/Wde?
Four comparable CEC modules such as Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q (235.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q Hanwha Qcells (Qidong) Co Ltd |
235.0 W | Tie (0 W) | 37.0 V | 14.54% | 89.0% |
| Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235QW Hanwha Qcells (Qidong) Co Ltd |
235.0 W | Tie (0 W) | 37.0 V | 14.54% | 89.0% |
| Centrosolar America DP60 235 Centrosolar America |
235.0 W | Tie (0 W) | 36.98 V | 14.33% | 90.0% |
| CSI Solar Co Ltd CS6P-235P CSI Solar Co Ltd |
235.0 W | Tie (0 W) | 36.9 V | 15.17% | 90.9% |
What Are the Design Limits and Best-Fit Uses for Suntech Power STP235-20/Wde?
Evaluate Suntech Power STP235-20/Wde (235.0 W STC, 37.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Suntech Power STP235-20/Wde reaches 42.66 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 35 panels for an 8 kW build require 622 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (622 sq ft).
- 2026 tax credit baseline: cash residential installs of Suntech Power STP235-20/Wde carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Suntech Power STP235-20/Wde 8 kW Residential Fit
Needs 35 modules (622 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 213.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Suntech Power STP235-20/Wde by Suntech Power grounded in CEC test data and NEC 690.7/690.8 limits.
How many Suntech Power STP235-20/Wde panels fit on a 600 V winter solar string?
At -10 C (14 F), Suntech Power STP235-20/Wde cold Voc rises from 37.0 V to 41.4 V (beta_Voc -0.34%/C), capping a 600 V string at 14 panels (579.6 V).
How much roof area does an 8 kW array of Suntech Power STP235-20/Wde need?
An 8 kW DC system uses 35 Suntech Power STP235-20/Wde modules (8,225 W STC / 7,486 W PTC), covering roughly 622 sq ft and saving ~$2,057/yr at 18.54 c/kWh.
How does Suntech Power STP235-20/Wde compare against Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q?
Suntech Power STP235-20/Wde outputs 235.0 W STC (37.0 V Voc, rank #20,368 of 21,677), while Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q delivers 235.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)