Skip to main content
WireAndSun
Calculators
CEC PV Module

Suntech Power STP215-20/Wd — CEC Solar Module Specifications

Manufacturer: Suntech Power Registry: CEC Verified Engineering Specification

Suntech Power STP215-20/Wd is a 215.0 W STC (194.7 W PTC) Multi-c-Si solar module ranking #20,859 of 21,677 CEC listings (below all-CEC median; higher than 3.5% of peers). It delivers 13.03% efficiency, 36.5 V Voc at 25 C, and 40.49 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
215.0 W
PTC Wattage
194.7 W
Voc @ 25C
36.5 V
Efficiency
13.03%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Suntech Power STP215-20/Wd Compare Against Peer CEC Listings?

Solar engineering breakdown for Suntech Power STP215-20/Wd: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 1,407 Multi-c-Si listings from Suntech Power and peers, Suntech Power STP215-20/Wd stands 63.8 W below the 278.8 W Multi-c-Si median and typical 90.6% PTC-to-STC thermal output (194.7 W real-world rating). Sizing 6 kW (28 panels) to 10 kW (47 panels) yields $1,507-$2,530/yr in baseline US bill offset. Lower 36.5 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does Suntech Power STP215-20/Wd Fall Across Listed CEC Models?

Distribution marker showing Suntech Power STP215-20/Wd (215.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Suntech Power STP215-20/Wd (215.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSuntech Power STP2: 215.0 W

What Dataset Percentiles Define Suntech Power STP215-20/Wd?

Dataset percentiles tracking Suntech Power STP215-20/Wd power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Suntech Power STP215-20/Wd Engineering BenchmarksPercentile comparison of Suntech Power STP215-20/Wd wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage215.0 WPTC/STC Retention90.6%Module Efficiency13.03%

What Do the Dataset Ranks Show for Suntech Power STP215-20/Wd?

Benchmark highlights for Suntech Power STP215-20/Wd covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #20,859 / 21,677

215.0 W STC · Higher Than 3.5%

215.0 W STC (-170.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,400

13.03% Aperture Efficiency

Power density 130.3 W/m2 (6.88 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.49 V at -10 C (566.9 V string) and 41.62 V at -20 C (14 max).

8 kW Reference Array

38 Panels = 8,170 W STC

Occupies 62.7 m2 (675 sq ft) producing 7,399 W PTC; NEC 690.8 OCPD floor is 12.4 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.5 * (1 + (-0.312/100) * (-10 - 25)) = 40.49 V | OCPD = 1.56 * 7.95 = 12.4 A

Inputs from CEC Modules.csv for Suntech Power STP215-20/Wd: Voc=36.5 V, beta_Voc=-0.312%/C, Isc=7.95 A, STC=215.0 W, Area=1.65 m2.

Result: 14 panels max on 600 V (566.9 V); 38 panels for 8 kW (675 sq ft).

What Are the Published CEC Specifications for Suntech Power STP215-20/Wd?

Official CEC datasheet figures for Suntech Power STP215-20/Wd (Multi-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for Suntech Power STP215-20/Wd.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 215.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 194.7 W (90.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 7.95 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.2 V / 7.37 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.312 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.03% (1.65 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Suntech Power STP215-20/Wd Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Suntech Power STP215-20/Wd modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 28 6.02 kW 497 sq ft $1,507 $2,548
8 kW Class 38 8.17 kW 675 sq ft $2,045 $3,458
10 kW Class 47 10.11 kW 835 sq ft $2,530 $4,279

Which Sibling Wattage & Trim Variants Belong to This Suntech Power Series?

Consolidated Suntech Power wattage variants sharing the Suntech Power STP215-20/Wd mechanical and cell layout. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the Suntech Power STP215-20/Wd wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Suntech Power STP210-20/Wd 210.0 W 190.0 W 36.4 V 29.0 V 12.73%
Suntech Power STP215-20/Wd 215.0 W 194.7 W 36.5 V 29.2 V 13.03%
Suntech Power STP220-20/Wd 220.0 W 199.3 W 36.6 V 29.5 V 13.33%

How Many Suntech Power STP215-20/Wd Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Suntech Power STP215-20/Wd (40.49 V at 14 F).

Computed from Voc=36.5V and beta_Voc=-0.312%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.62 V 14 panels 582.7 V 24 panels
-10 C (14 F) 40.49 V 14 panels 566.9 V 24 panels
0 C (32 F) 39.35 V 15 panels 590.2 V 25 panels
25 C (77 F STC) 36.5 V 16 panels 584.0 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to Suntech Power STP215-20/Wd?

Competing CEC solar panels closest to Suntech Power STP215-20/Wd in nameplate wattage and Voc, starting with Anji Dasol Solar Energy Science & Technology DS-A4-215.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Anji Dasol Solar Energy Science & Technology DS-A4-215
Anji Dasol Solar Energy Science & Technology
215.0 W Tie (0 W) 36.3 V 13.06% 87.1%
APOS Energy AP215
APOS Energy
215.0 W Tie (0 W) 36.79 V 12.96% 88.8%
CSI Solar Co Ltd CS6P-215M
CSI Solar Co Ltd
215.0 W Tie (0 W) 36.8 V 13.88% 90.2%
Advance Power API-P215
Advance Power
215.0 W Tie (0 W) 36.0 V 13.13% 89.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Suntech Power STP215-20/Wd?

Evaluate Suntech Power STP215-20/Wd (215.0 W STC, 36.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Suntech Power STP215-20/Wd reaches 41.62 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 38 panels for an 8 kW build require 675 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 38 panels (675 sq ft).
  • 2026 tax credit baseline: cash residential installs of Suntech Power STP215-20/Wd carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Suntech Power STP215-20/Wd 8 kW Residential Fit

Needs 38 modules (675 sq ft) with a 15 A string OCPD, offsetting ~$2,045/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Anji Dasol Solar Energy Science & Technology DS-A4-215.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 194.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Suntech Power STP215-20/Wd by Suntech Power grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Suntech Power STP215-20/Wd?

Multiplying Suntech Power STP215-20/Wd's 7.95 A short-circuit current by 1.56 equals 12.4 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Suntech Power STP215-20/Wd pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.49 V cold Voc at 14 F and handles 7.95 A Isc; string inverters cap Suntech Power STP215-20/Wd at 14 panels on 600 V.

Is Suntech Power STP215-20/Wd eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Suntech Power STP215-20/Wd rely on utility bill offset (~$2,045/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.