Suntech Power STP215-20/Wd is a 215.0 W STC (194.7 W PTC) Multi-c-Si solar module ranking #20,859 of 21,677 CEC listings (below all-CEC median; higher than 3.5% of peers). It delivers 13.03% efficiency, 36.5 V Voc at 25 C, and 40.49 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 215.0 W
- PTC Wattage
- 194.7 W
- Voc @ 25C
- 36.5 V
- Efficiency
- 13.03%
How Does Suntech Power STP215-20/Wd Compare Against Peer CEC Listings?
Solar engineering breakdown for Suntech Power STP215-20/Wd: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 1,407 Multi-c-Si listings from Suntech Power and peers, Suntech Power STP215-20/Wd stands 63.8 W below the 278.8 W Multi-c-Si median and typical 90.6% PTC-to-STC thermal output (194.7 W real-world rating). Sizing 6 kW (28 panels) to 10 kW (47 panels) yields $1,507-$2,530/yr in baseline US bill offset. Lower 36.5 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Suntech Power STP215-20/Wd Fall Across Listed CEC Models?
Distribution marker showing Suntech Power STP215-20/Wd (215.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Suntech Power STP215-20/Wd?
Dataset percentiles tracking Suntech Power STP215-20/Wd power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Suntech Power STP215-20/Wd?
Benchmark highlights for Suntech Power STP215-20/Wd covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
215.0 W STC · Higher Than 3.5%
215.0 W STC (-170.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.03% Aperture Efficiency
Power density 130.3 W/m2 (6.88 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.49 V at -10 C (566.9 V string) and 41.62 V at -20 C (14 max).
38 Panels = 8,170 W STC
Occupies 62.7 m2 (675 sq ft) producing 7,399 W PTC; NEC 690.8 OCPD floor is 12.4 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.5 * (1 + (-0.312/100) * (-10 - 25)) = 40.49 V | OCPD = 1.56 * 7.95 = 12.4 A
Inputs from CEC Modules.csv for Suntech Power STP215-20/Wd: Voc=36.5 V, beta_Voc=-0.312%/C, Isc=7.95 A, STC=215.0 W, Area=1.65 m2.
Result: 14 panels max on 600 V (566.9 V); 38 panels for 8 kW (675 sq ft).
What Are the Published CEC Specifications for Suntech Power STP215-20/Wd?
Official CEC datasheet figures for Suntech Power STP215-20/Wd (Multi-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 215.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 194.7 W (90.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 7.95 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 29.2 V / 7.37 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.312 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.03% (1.65 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Suntech Power STP215-20/Wd Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Suntech Power STP215-20/Wd modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 28 | 6.02 kW | 497 sq ft | $1,507 | $2,548 |
| 8 kW Class | 38 | 8.17 kW | 675 sq ft | $2,045 | $3,458 |
| 10 kW Class | 47 | 10.11 kW | 835 sq ft | $2,530 | $4,279 |
Which Sibling Wattage & Trim Variants Belong to This Suntech Power Series?
Consolidated Suntech Power wattage variants sharing the Suntech Power STP215-20/Wd mechanical and cell layout. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Suntech Power STP210-20/Wd | 210.0 W | 190.0 W | 36.4 V | 29.0 V | 12.73% |
| Suntech Power STP215-20/Wd | 215.0 W | 194.7 W | 36.5 V | 29.2 V | 13.03% |
| Suntech Power STP220-20/Wd | 220.0 W | 199.3 W | 36.6 V | 29.5 V | 13.33% |
How Many Suntech Power STP215-20/Wd Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Suntech Power STP215-20/Wd (40.49 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.62 V | 14 panels | 582.7 V | 24 panels |
| -10 C (14 F) | 40.49 V | 14 panels | 566.9 V | 24 panels |
| 0 C (32 F) | 39.35 V | 15 panels | 590.2 V | 25 panels |
| 25 C (77 F STC) | 36.5 V | 16 panels | 584.0 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to Suntech Power STP215-20/Wd?
Competing CEC solar panels closest to Suntech Power STP215-20/Wd in nameplate wattage and Voc, starting with Anji Dasol Solar Energy Science & Technology DS-A4-215.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Anji Dasol Solar Energy Science & Technology DS-A4-215 Anji Dasol Solar Energy Science & Technology |
215.0 W | Tie (0 W) | 36.3 V | 13.06% | 87.1% |
| APOS Energy AP215 APOS Energy |
215.0 W | Tie (0 W) | 36.79 V | 12.96% | 88.8% |
| CSI Solar Co Ltd CS6P-215M CSI Solar Co Ltd |
215.0 W | Tie (0 W) | 36.8 V | 13.88% | 90.2% |
| Advance Power API-P215 Advance Power |
215.0 W | Tie (0 W) | 36.0 V | 13.13% | 89.0% |
What Are the Design Limits and Best-Fit Uses for Suntech Power STP215-20/Wd?
Evaluate Suntech Power STP215-20/Wd (215.0 W STC, 36.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Suntech Power STP215-20/Wd reaches 41.62 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 38 panels for an 8 kW build require 675 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 38 panels (675 sq ft).
- 2026 tax credit baseline: cash residential installs of Suntech Power STP215-20/Wd carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Suntech Power STP215-20/Wd 8 kW Residential Fit
Needs 38 modules (675 sq ft) with a 15 A string OCPD, offsetting ~$2,045/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Anji Dasol Solar Energy Science & Technology DS-A4-215.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 194.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Suntech Power STP215-20/Wd by Suntech Power grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Suntech Power STP215-20/Wd?
Multiplying Suntech Power STP215-20/Wd's 7.95 A short-circuit current by 1.56 equals 12.4 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Suntech Power STP215-20/Wd pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 40.49 V cold Voc at 14 F and handles 7.95 A Isc; string inverters cap Suntech Power STP215-20/Wd at 14 panels on 600 V.
Is Suntech Power STP215-20/Wd eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Suntech Power STP215-20/Wd rely on utility bill offset (~$2,045/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)