Skip to main content
WireAndSun
Calculators
CEC PV Module

SunPower SPR-MAX3-430-COM-R — CEC Solar Module Specifications

Manufacturer: SunPower Registry: CEC Verified Engineering Specification

SunPower SPR-MAX3-430-COM-R is a 430.0 W STC (406.7 W PTC) Mono-c-Si solar module ranking #7,266 of 21,677 CEC listings (top 35.2%; higher than 64.8% of peers). It delivers 22.63% efficiency, 40.68 V Voc at 25 C, and 44.01 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
430.0 W
PTC Wattage
406.7 W
Voc @ 25C
40.68 V
Efficiency
22.63%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SunPower SPR-MAX3-430-COM-R Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for SunPower SPR-MAX3-430-COM-R (Mono-c-Si) residential solar systems. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Homeowners evaluating SunPower SPR-MAX3-430-COM-R need 14 panels for 6 kW or 19 panels (389 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 19 panels (389 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.234%/C) pushes open-circuit voltage to 44.01 V at 14 F and 44.96 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does SunPower SPR-MAX3-430-COM-R Fall Across Listed CEC Models?

Comparison of SunPower SPR-MAX3-430-COM-R (430.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SunPower SPR-MAX3-430-COM-R (430.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunPower SPR-MAX3-: 430.0 W

What Dataset Percentiles Define SunPower SPR-MAX3-430-COM-R?

Relative ranking of SunPower SPR-MAX3-430-COM-R across nameplate watts, 94.6% PTC thermal ratio, and module aperture efficiency. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

SunPower SPR-MAX3-430-COM-R Engineering BenchmarksPercentile comparison of SunPower SPR-MAX3-430-COM-R wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage430.0 WPTC/STC Retention94.6%Module Efficiency22.63%

What Do the Dataset Ranks Show for SunPower SPR-MAX3-430-COM-R?

Summary of SunPower SPR-MAX3-430-COM-R output rank, 8 kW array size (19 panels), efficiency rating, and 600 V string limit.

Rank #7,266 / 21,677

Top 35.2% STC Output

430.0 W STC (+45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,792

22.63% Aperture Efficiency

Power density 226.3 W/m2 (2.72 percentage points above 19.91% CEC median). PTC/STC ratio: 94.6% (rank #2,348).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.01 V at -10 C (572.1 V string) and 44.96 V at -20 C (13 max).

8 kW Reference Array

19 Panels = 8,170 W STC

Occupies 36.1 m2 (389 sq ft) producing 7,727 W PTC; NEC 690.8 OCPD floor is 20.51 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.68 * (1 + (-0.234/100) * (-10 - 25)) = 44.01 V | OCPD = 1.56 * 13.15 = 20.51 A

Inputs from CEC Modules.csv for SunPower SPR-MAX3-430-COM-R: Voc=40.68 V, beta_Voc=-0.234%/C, Isc=13.15 A, STC=430.0 W, Area=1.9 m2.

Result: 13 panels max on 600 V (572.1 V); 19 panels for 8 kW (389 sq ft).

What Are the Published CEC Specifications for SunPower SPR-MAX3-430-COM-R?

Complete CEC test sheet for SunPower SPR-MAX3-430-COM-R including Isc (13.15 A), Voc (40.68 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for SunPower SPR-MAX3-430-COM-R.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 430.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 406.7 W (94.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.68 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.15 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 35.11 V / 12.25 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.234 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.63% (1.9 m2) Array roof footprint density
Cell Count & Technology 112 cells (Mono-c-Si) Monofacial backsheet

How Many SunPower SPR-MAX3-430-COM-R Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using SunPower SPR-MAX3-430-COM-R.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.02 kW 286 sq ft $1,507 $2,548
8 kW Class 19 8.17 kW 389 sq ft $2,045 $3,458
10 kW Class 24 10.32 kW 491 sq ft $2,583 $4,368

Which Sibling Wattage & Trim Variants Belong to This SunPower Series?

Related SunPower power steps and black/silver trims consolidated into this SunPower SPR-MAX3-430-COM-R series guide. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the SunPower SPR-MAX3-430-COM-R wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SunPower SPR-MAX3-425-COM-R 425.0 W 401.9 W 40.66 V 34.9 V 22.37%
SunPower SPR-MAX3-430-COM-R 430.0 W 406.7 W 40.68 V 35.11 V 22.63%
SunPower SPR-MAX3-435-COM-R 435.0 W 411.6 W 40.7 V 35.31 V 22.89%

How Many SunPower SPR-MAX3-430-COM-R Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for SunPower SPR-MAX3-430-COM-R (40.68 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=40.68V and beta_Voc=-0.234%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.96 V 13 panels 584.5 V 22 panels
-10 C (14 F) 44.01 V 13 panels 572.1 V 22 panels
0 C (32 F) 43.06 V 13 panels 559.8 V 23 panels
25 C (77 F STC) 40.68 V 14 panels 569.5 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to SunPower SPR-MAX3-430-COM-R?

Four comparable CEC modules such as CertainTeed CTM10435HC11-06 (435.0 W) for side-by-side solar quote checks. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CertainTeed CTM10435HC11-06
CertainTeed
435.0 W +5.0 W 40.95 V 20.14% 93.7%
Boviet Solar Technology Co Ltd BVM7609M-430-H-HC
Boviet Solar Technology Co Ltd
430.0 W Tie (0 W) 39.04 V 19.91% 94.8%
Boviet Solar Technology Co Ltd BVM7610M-435-H-HC
Boviet Solar Technology Co Ltd
435.0 W +5.0 W 41.21 V 20.71% 94.0%
AE Solar GmbH AE435CMD-108BDE
AE Solar GmbH
435.0 W +5.0 W 40.1 V 22.31% 94.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SunPower SPR-MAX3-430-COM-R?

Evaluate SunPower SPR-MAX3-430-COM-R (430.0 W STC, 40.68 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SunPower SPR-MAX3-430-COM-R reaches 44.96 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 389 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (389 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of SunPower SPR-MAX3-430-COM-R carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SunPower SPR-MAX3-430-COM-R 8 kW Residential Fit

Needs 19 modules (389 sq ft) with a 25 A string OCPD, offsetting ~$2,045/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CertainTeed CTM10435HC11-06.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 406.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SunPower SPR-MAX3-430-COM-R by SunPower grounded in CEC test data and NEC 690.7/690.8 limits. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Why is SunPower SPR-MAX3-430-COM-R PTC wattage (406.7 W) lower than STC (430.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 406.7 W PTC (94.6% retention) across SunPower SPR-MAX3-430-COM-R's 1.9 m2 aperture.

Who should skip SunPower SPR-MAX3-430-COM-R on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 SunPower SPR-MAX3-430-COM-R panels (389 sq ft) leave unusable roof gaps vs. CertainTeed CTM10435HC11-06.

What is the 1,000 V commercial string limit for SunPower SPR-MAX3-430-COM-R?

On 1,000 V commercial inverters at -10 C (44.01 V cold Voc), SunPower SPR-MAX3-430-COM-R fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting SunPower SPR-MAX3-430-COM-R.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.