SunPower SPR-MAX3-400-COM is a 400.0 W STC (372.4 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 22.6% efficiency, 75.4 V Voc at 25 C, and 81.42 V cold Voc at -10 C (7 panels max per 600 V string).
- STC Wattage
- 400.0 W
- PTC Wattage
- 372.4 W
- Voc @ 25C
- 75.4 V
- Efficiency
- 22.6%
How Does SunPower SPR-MAX3-400-COM Compare Against Peer CEC Listings?
Engineering position of SunPower SPR-MAX3-400-COM (400.0 W STC) vs. CSI Solar Co Ltd CS1Y-410MS across 5,889 CEC Mono-c-Si solar modules.
Ranking #9,407 across 21,677 CEC solar panels (top 45.5%; higher than 54.5% of peers), SunPower SPR-MAX3-400-COM operates as a modern high-density residential and light-commercial module sitting 10.0 W below the 410.0 W Mono-c-Si median. Higher 75.4 V open-circuit voltage caps 600 V residential strings at 7 panels at 14 F (-10 C). With strong 93.1% PTC-to-STC heat retention (#9,420 of 21,677), 20 panels occupy 381 sq ft and offset roughly $2,002/yr at average US rates (or $3,386/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does SunPower SPR-MAX3-400-COM Fall Across Listed CEC Models?
Plots SunPower SPR-MAX3-400-COM at 400.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define SunPower SPR-MAX3-400-COM?
Benchmarks SunPower SPR-MAX3-400-COM on STC wattage, thermal PTC/STC retention, and 22.6 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for SunPower SPR-MAX3-400-COM?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for SunPower SPR-MAX3-400-COM by SunPower.
Top 45.5% STC Output
400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.6% Aperture Efficiency
Power density 226.0 W/m2 (2.69 percentage points above 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).
7 Panels Max @ -10 C (600 V)
Cold Voc reaches 81.42 V at -10 C (569.9 V string) and 83.14 V at -20 C (7 max).
20 Panels = 8,000 W STC
Occupies 35.4 m2 (381 sq ft) producing 7,448 W PTC; NEC 690.8 OCPD floor is 10.25 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 75.4 * (1 + (-0.228/100) * (-10 - 25)) = 81.42 V | OCPD = 1.56 * 6.57 = 10.25 A
Inputs from CEC Modules.csv for SunPower SPR-MAX3-400-COM: Voc=75.4 V, beta_Voc=-0.228%/C, Isc=6.57 A, STC=400.0 W, Area=1.77 m2.
Result: 7 panels max on 600 V (569.9 V); 20 panels for 8 kW (381 sq ft).
What Are the Published CEC Specifications for SunPower SPR-MAX3-400-COM?
Laboratory test ratings recorded for SunPower SPR-MAX3-400-COM (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 400.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 372.4 W (93.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 75.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 6.57 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 66.0 V / 6.07 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.228 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.6% (1.77 m2) | Array roof footprint density |
| Cell Count & Technology | 104 cells (Mono-c-Si) | Monofacial backsheet |
How Many SunPower SPR-MAX3-400-COM Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (381 sq ft at 8 kW), and estimated Year-1 electric bill offset for SunPower SPR-MAX3-400-COM.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.0 kW | 286 sq ft | $1,502 | $2,539 |
| 8 kW Class | 20 | 8.0 kW | 381 sq ft | $2,002 | $3,386 |
| 10 kW Class | 25 | 10.0 kW | 476 sq ft | $2,503 | $4,232 |
How Many SunPower SPR-MAX3-400-COM Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for SunPower SPR-MAX3-400-COM (beta_Voc -0.228%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 83.14 V | 7 panels | 582.0 V | 12 panels |
| -10 C (14 F) | 81.42 V | 7 panels | 569.9 V | 12 panels |
| 0 C (32 F) | 79.7 V | 7 panels | 557.9 V | 12 panels |
| 25 C (77 F STC) | 75.4 V | 7 panels | 527.8 V | 13 panels |
Which Cross-Brand Solar Modules Compare Closest to SunPower SPR-MAX3-400-COM?
Closest cross-brand CEC competitors to SunPower SPR-MAX3-400-COM matched near 400.0 W STC and 75.4 V Voc, led by CSI Solar Co Ltd CS1Y-410MS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS1Y-410MS CSI Solar Co Ltd |
410.0 W | +10.0 W | 52.7 V | 21.03% | 94.1% |
| Boviet Solar Technology Co Ltd BVM6612M-400-H Boviet Solar Technology Co Ltd |
400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| Boviet Solar Technology Co Ltd BVM6612M-W5-400-H Boviet Solar Technology Co Ltd |
400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| Boviet Solar Technology Co Ltd BVM6612M-405L-H Boviet Solar Technology Co Ltd |
405.0 W | +5.0 W | 49.45 V | 20.35% | 93.3% |
What Are the Design Limits and Best-Fit Uses for SunPower SPR-MAX3-400-COM?
Evaluate SunPower SPR-MAX3-400-COM (400.0 W STC, 75.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), SunPower SPR-MAX3-400-COM reaches 83.14 V per panel—exceeding 7 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 381 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (381 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of SunPower SPR-MAX3-400-COM carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
SunPower SPR-MAX3-400-COM 8 kW Residential Fit
Needs 20 modules (381 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 7 panels (-10 C) or 7 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-410MS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 372.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for SunPower SPR-MAX3-400-COM by SunPower grounded in CEC test data and NEC 690.7/690.8 limits. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
How many SunPower SPR-MAX3-400-COM panels fit on a 600 V winter solar string?
At -10 C (14 F), SunPower SPR-MAX3-400-COM cold Voc rises from 75.4 V to 81.42 V (beta_Voc -0.228%/C), capping a 600 V string at 7 panels (569.9 V).
How much roof area does an 8 kW array of SunPower SPR-MAX3-400-COM need?
An 8 kW DC system uses 20 SunPower SPR-MAX3-400-COM modules (8,000 W STC / 7,448 W PTC), covering roughly 381 sq ft and saving ~$2,002/yr at 18.54 c/kWh.
How does SunPower SPR-MAX3-400-COM compare against CSI Solar Co Ltd CS1Y-410MS?
SunPower SPR-MAX3-400-COM outputs 400.0 W STC (75.4 V Voc, rank #9,407 of 21,677), while CSI Solar Co Ltd CS1Y-410MS delivers 410.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)