Manufacturer: SunPower Registry: CEC Verified Engineering Specification

SunPower SPR-MAX3-390-COM is a 390.0 W STC (362.8 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 22.03% efficiency, 75.3 V Voc at 25 C, and 81.31 V cold Voc at -10 C (7 panels max per 600 V string).

STC Wattage
390.0 W
PTC Wattage
362.8 W
Voc @ 25C
75.3 V
Efficiency
22.03%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SunPower SPR-MAX3-390-COM Compare Against Peer CEC Listings?

Engineering position of SunPower SPR-MAX3-390-COM (390.0 W STC) vs. CSI Solar Co Ltd CS1Y-390MS across 5,889 CEC Mono-c-Si solar modules.

Ranking #10,321 across 21,677 CEC solar panels (top 49.5%; higher than 50.5% of peers), SunPower SPR-MAX3-390-COM operates as a modern high-density residential and light-commercial module sitting 20.0 W below the 410.0 W Mono-c-Si median. Higher 75.3 V open-circuit voltage caps 600 V residential strings at 7 panels at 14 F (-10 C). With strong 93.0% PTC-to-STC heat retention (#9,879 of 21,677), 21 panels occupy 400 sq ft and offset roughly $2,050/yr at average US rates (or $3,466/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does SunPower SPR-MAX3-390-COM Fall Across Listed CEC Models?

Plots SunPower SPR-MAX3-390-COM at 390.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SunPower SPR-MAX3-390-COM (390.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunPower SPR-MAX3-: 390.0 W

What Dataset Percentiles Define SunPower SPR-MAX3-390-COM?

Benchmarks SunPower SPR-MAX3-390-COM on STC wattage, thermal PTC/STC retention, and 22.03 aperture conversion efficiency against CEC peers.

SunPower SPR-MAX3-390-COM Engineering BenchmarksPercentile comparison of SunPower SPR-MAX3-390-COM wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage390.0 WPTC/STC Retention93.0%Module Efficiency22.03%

What Do the Dataset Ranks Show for SunPower SPR-MAX3-390-COM?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for SunPower SPR-MAX3-390-COM by SunPower.

Rank #10,321 / 21,677

Top 49.5% STC Output

390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,050

22.03% Aperture Efficiency

Power density 220.3 W/m2 (2.12 percentage points above 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

7 Panels Max @ -10 C (600 V)

Cold Voc reaches 81.31 V at -10 C (569.2 V string) and 83.03 V at -20 C (7 max).

8 kW Reference Array

21 Panels = 8,190 W STC

Occupies 37.2 m2 (400 sq ft) producing 7,619 W PTC; NEC 690.8 OCPD floor is 10.22 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 75.3 * (1 + (-0.228/100) * (-10 - 25)) = 81.31 V | OCPD = 1.56 * 6.55 = 10.22 A

Inputs from CEC Modules.csv for SunPower SPR-MAX3-390-COM: Voc=75.3 V, beta_Voc=-0.228%/C, Isc=6.55 A, STC=390.0 W, Area=1.77 m2.

Result: 7 panels max on 600 V (569.2 V); 21 panels for 8 kW (400 sq ft).

What Are the Published CEC Specifications for SunPower SPR-MAX3-390-COM?

Laboratory test ratings recorded for SunPower SPR-MAX3-390-COM (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for SunPower SPR-MAX3-390-COM.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 390.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 362.8 W (93.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 75.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 6.55 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 64.5 V / 6.05 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.228 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.03% (1.77 m2) Array roof footprint density
Cell Count & Technology 104 cells (Mono-c-Si) Monofacial backsheet

How Many SunPower SPR-MAX3-390-COM Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (400 sq ft at 8 kW), and estimated Year-1 electric bill offset for SunPower SPR-MAX3-390-COM.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.24 kW 305 sq ft $1,562 $2,641
8 kW Class 21 8.19 kW 400 sq ft $2,050 $3,466
10 kW Class 26 10.14 kW 495 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This SunPower Series?

Sibling wattage bins and frame colors grouped with SunPower SPR-MAX3-390-COM under SunPower to prevent duplicate spec pages. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the SunPower SPR-MAX3-390-COM wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SunPower SPR-MAX3-380-COM 380.0 W 353.3 W 75.2 V 63.1 V 21.47%
SunPower SPR-MAX3-390-COM 390.0 W 362.8 W 75.3 V 64.5 V 22.03%

How Many SunPower SPR-MAX3-390-COM Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for SunPower SPR-MAX3-390-COM (beta_Voc -0.228%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=75.3V and beta_Voc=-0.228%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 83.03 V 7 panels 581.2 V 12 panels
-10 C (14 F) 81.31 V 7 panels 569.2 V 12 panels
0 C (32 F) 79.59 V 7 panels 557.1 V 12 panels
25 C (77 F STC) 75.3 V 7 panels 527.1 V 13 panels

Which Cross-Brand Solar Modules Compare Closest to SunPower SPR-MAX3-390-COM?

Closest cross-brand CEC competitors to SunPower SPR-MAX3-390-COM matched near 390.0 W STC and 75.3 V Voc, led by CSI Solar Co Ltd CS1Y-390MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS1Y-390MS
CSI Solar Co Ltd
390.0 W Tie (0 W) 51.9 V 20.0% 94.0%
BYD Company Limited BYD415MIK-36
BYD Company Limited
395.0 W +5.0 W 50.06 V 19.65% 93.9%
ELITE Solar ET-M672BH395GL
ELITE Solar
395.0 W +5.0 W 49.6 V 19.36% 93.2%
ELITE Solar ET-M672BH395WW
ELITE Solar
395.0 W +5.0 W 49.5 V 19.85% 93.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SunPower SPR-MAX3-390-COM?

Evaluate SunPower SPR-MAX3-390-COM (390.0 W STC, 75.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SunPower SPR-MAX3-390-COM reaches 83.03 V per panel—exceeding 7 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 400 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (400 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of SunPower SPR-MAX3-390-COM carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SunPower SPR-MAX3-390-COM 8 kW Residential Fit

Needs 21 modules (400 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 7 panels (-10 C) or 7 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-390MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 362.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SunPower SPR-MAX3-390-COM by SunPower grounded in CEC test data and NEC 690.7/690.8 limits. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

How many SunPower SPR-MAX3-390-COM panels fit on a 600 V winter solar string?

At -10 C (14 F), SunPower SPR-MAX3-390-COM cold Voc rises from 75.3 V to 81.31 V (beta_Voc -0.228%/C), capping a 600 V string at 7 panels (569.2 V).

How much roof area does an 8 kW array of SunPower SPR-MAX3-390-COM need?

An 8 kW DC system uses 21 SunPower SPR-MAX3-390-COM modules (8,190 W STC / 7,619 W PTC), covering roughly 400 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

How does SunPower SPR-MAX3-390-COM compare against CSI Solar Co Ltd CS1Y-390MS?

SunPower SPR-MAX3-390-COM outputs 390.0 W STC (75.3 V Voc, rank #10,321 of 21,677), while CSI Solar Co Ltd CS1Y-390MS delivers 390.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls