Sun Gold Power Inc SG415WM is a 415.0 W STC (392.3 W PTC) Mono-c-Si solar module ranking #8,199 of 21,677 CEC listings (top 39.4%; higher than 60.6% of peers). It delivers 21.84% efficiency, 37.6 V Voc at 25 C, and 41.01 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 415.0 W
- PTC Wattage
- 392.3 W
- Voc @ 25C
- 37.6 V
- Efficiency
- 21.84%
How Does Sun Gold Power Inc SG415WM Compare Against Peer CEC Listings?
Solar engineering breakdown for Sun Gold Power Inc SG415WM: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Sun Gold Power Inc and peers, Sun Gold Power Inc SG415WM stands 5.0 W above the 410.0 W Mono-c-Si median and strong 94.5% PTC-to-STC heat retention (#2,573 of 21,677). Sizing 6 kW (15 panels) to 10 kW (25 panels) yields $1,557-$2,598/yr in baseline US bill offset. Lower 37.6 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Sun Gold Power Inc SG415WM Fall Across Listed CEC Models?
Distribution marker showing Sun Gold Power Inc SG415WM (415.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Sun Gold Power Inc SG415WM?
Dataset percentiles tracking Sun Gold Power Inc SG415WM power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Sun Gold Power Inc SG415WM?
Benchmark highlights for Sun Gold Power Inc SG415WM covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 39.4% STC Output
415.0 W STC (+30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.84% Aperture Efficiency
Power density 218.4 W/m2 (1.93 percentage points above 19.91% CEC median). PTC/STC ratio: 94.5% (rank #2,573).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.01 V at -10 C (574.1 V string) and 41.98 V at -20 C (14 max).
20 Panels = 8,300 W STC
Occupies 38.0 m2 (409 sq ft) producing 7,846 W PTC; NEC 690.8 OCPD floor is 21.72 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.6 * (1 + (-0.259/100) * (-10 - 25)) = 41.01 V | OCPD = 1.56 * 13.92 = 21.72 A
Inputs from CEC Modules.csv for Sun Gold Power Inc SG415WM: Voc=37.6 V, beta_Voc=-0.259%/C, Isc=13.92 A, STC=415.0 W, Area=1.9 m2.
Result: 14 panels max on 600 V (574.1 V); 20 panels for 8 kW (409 sq ft).
What Are the Published CEC Specifications for Sun Gold Power Inc SG415WM?
Official CEC datasheet figures for Sun Gold Power Inc SG415WM (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 415.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 392.3 W (94.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.92 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.6 V / 13.13 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.259 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.84% (1.9 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many Sun Gold Power Inc SG415WM Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Sun Gold Power Inc SG415WM modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.22 kW | 307 sq ft | $1,557 | $2,632 |
| 8 kW Class | 20 | 8.3 kW | 409 sq ft | $2,077 | $3,513 |
| 10 kW Class | 25 | 10.38 kW | 511 sq ft | $2,598 | $4,393 |
Which Sibling Wattage & Trim Variants Belong to This Sun Gold Power Inc Series?
Consolidated Sun Gold Power Inc wattage variants sharing the Sun Gold Power Inc SG415WM mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Sun Gold Power Inc SG405WM | 405.0 W | 382.7 W | 37.3 V | 31.4 V | 21.32% |
| Sun Gold Power Inc SG410WM | 410.0 W | 387.5 W | 37.5 V | 31.5 V | 21.58% |
| Sun Gold Power Inc SG415WM | 415.0 W | 392.3 W | 37.6 V | 31.6 V | 21.84% |
| Sun Gold Power Inc SG420WM | 420.0 W | 397.2 W | 37.7 V | 31.7 V | 22.11% |
How Many Sun Gold Power Inc SG415WM Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Sun Gold Power Inc SG415WM (41.01 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.98 V | 14 panels | 587.7 V | 23 panels |
| -10 C (14 F) | 41.01 V | 14 panels | 574.1 V | 24 panels |
| 0 C (32 F) | 40.03 V | 14 panels | 560.4 V | 24 panels |
| 25 C (77 F STC) | 37.6 V | 15 panels | 564.0 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Sun Gold Power Inc SG415WM?
Competing CEC solar panels closest to Sun Gold Power Inc SG415WM in nameplate wattage and Voc, starting with Aptos Solar Technology LLC DNA-108-BF10-415W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-BF10-415W Aptos Solar Technology LLC |
415.0 W | Tie (0 W) | 37.5 V | 21.28% | 94.3% |
| Aptos Solar Technology LLC DNA-108-MF10-415W-USAptos1a Aptos Solar Technology LLC |
415.0 W | Tie (0 W) | 37.7 V | 21.39% | 93.0% |
| AXITEC AC-415MH/108V AXITEC |
415.0 W | Tie (0 W) | 37.38 V | 21.5% | 92.7% |
| AXITEC AC-415TGB/108BB AXITEC |
415.0 W | Tie (0 W) | 38.04 V | 21.84% | 94.9% |
What Are the Design Limits and Best-Fit Uses for Sun Gold Power Inc SG415WM?
Evaluate Sun Gold Power Inc SG415WM (415.0 W STC, 37.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Sun Gold Power Inc SG415WM reaches 41.98 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 409 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (409 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Sun Gold Power Inc SG415WM carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Sun Gold Power Inc SG415WM 8 kW Residential Fit
Needs 20 modules (409 sq ft) with a 25 A string OCPD, offsetting ~$2,077/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Aptos Solar Technology LLC DNA-108-BF10-415W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 392.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Sun Gold Power Inc SG415WM by Sun Gold Power Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Sun Gold Power Inc SG415WM?
Multiplying Sun Gold Power Inc SG415WM's 13.92 A short-circuit current by 1.56 equals 21.72 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Sun Gold Power Inc SG415WM pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 41.01 V cold Voc at 14 F and handles 13.92 A Isc; string inverters cap Sun Gold Power Inc SG415WM at 14 panels on 600 V.
Is Sun Gold Power Inc SG415WM eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Sun Gold Power Inc SG415WM rely on utility bill offset (~$2,077/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)