Skip to main content
WireAndSun
Calculators
CEC PV Module

Solartech Energy ASC-6M-60A-275-3BB — CEC Solar Module Specifications

Manufacturer: Solartech Energy Registry: CEC Verified Engineering Specification

Solartech Energy ASC-6M-60A-275-3BB is a 275.0 W STC (250.0 W PTC) Mono-c-Si solar module ranking #18,259 of 21,677 CEC listings (below all-CEC median; higher than 14.3% of peers). It delivers 16.77% efficiency, 39.1 V Voc at 25 C, and 43.53 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
275.0 W
PTC Wattage
250.0 W
Voc @ 25C
39.1 V
Efficiency
16.77%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Solartech Energy ASC-6M-60A-275-3BB Compare Against Peer CEC Listings?

Solar engineering breakdown for Solartech Energy ASC-6M-60A-275-3BB: PTC thermal retention, roof footprint, and cold Voc string bounds. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Measured at 275.0 W STC and 250.0 W PTC, Solartech Energy ASC-6M-60A-275-3BB sits -110.0 W vs all-CEC median (below all-CEC median; higher than 14.3% of peers) among 21,677 listed modules. Power density reaches 167.7 W/m2 (3.14 percentage points below 19.91% CEC median). Lower 39.1 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 22 panels in series. Alternative peer Centrosolar America DM60 275 rates 275.0 W.

Where Does Solartech Energy ASC-6M-60A-275-3BB Fall Across Listed CEC Models?

Distribution marker showing Solartech Energy ASC-6M-60A-275-3BB (275.0 W) relative to the 385.0 W all-CEC solar panel median. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Solartech Energy ASC-6M-60A-275-3BB (275.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSolartech Energy A: 275.0 W

What Dataset Percentiles Define Solartech Energy ASC-6M-60A-275-3BB?

Dataset percentiles tracking Solartech Energy ASC-6M-60A-275-3BB power output, thermal retention ratio, and aperture efficiency against 21,677 models. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Solartech Energy ASC-6M-60A-275-3BB Engineering BenchmarksPercentile comparison of Solartech Energy ASC-6M-60A-275-3BB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage275.0 WPTC/STC Retention90.9%Module Efficiency16.77%

What Do the Dataset Ranks Show for Solartech Energy ASC-6M-60A-275-3BB?

Benchmark highlights for Solartech Energy ASC-6M-60A-275-3BB covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #18,259 / 21,677

275.0 W STC · Higher Than 14.3%

275.0 W STC (-110.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #16,838

16.77% Aperture Efficiency

Power density 167.7 W/m2 (3.14 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.53 V at -10 C (565.9 V string) and 44.8 V at -20 C (13 max).

8 kW Reference Array

30 Panels = 8,250 W STC

Occupies 49.2 m2 (530 sq ft) producing 7,500 W PTC; NEC 690.8 OCPD floor is 14.04 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.1 * (1 + (-0.324/100) * (-10 - 25)) = 43.53 V | OCPD = 1.56 * 9.0 = 14.04 A

Inputs from CEC Modules.csv for Solartech Energy ASC-6M-60A-275-3BB: Voc=39.1 V, beta_Voc=-0.324%/C, Isc=9.0 A, STC=275.0 W, Area=1.64 m2.

Result: 13 panels max on 600 V (565.9 V); 30 panels for 8 kW (530 sq ft).

What Are the Published CEC Specifications for Solartech Energy ASC-6M-60A-275-3BB?

Official CEC datasheet figures for Solartech Energy ASC-6M-60A-275-3BB (Mono-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Official California Energy Commission (NREL SAM) test parameters for Solartech Energy ASC-6M-60A-275-3BB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 275.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 250.0 W (90.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.0 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.8 V / 8.4 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.324 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.77% (1.64 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Solartech Energy ASC-6M-60A-275-3BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Solartech Energy ASC-6M-60A-275-3BB modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.05 kW 388 sq ft $1,514 $2,561
8 kW Class 30 8.25 kW 530 sq ft $2,065 $3,492
10 kW Class 37 10.18 kW 653 sq ft $2,548 $4,308

How Many Solartech Energy ASC-6M-60A-275-3BB Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Solartech Energy ASC-6M-60A-275-3BB (43.53 V at 14 F).

Computed from Voc=39.1V and beta_Voc=-0.324%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.8 V 13 panels 582.4 V 22 panels
-10 C (14 F) 43.53 V 13 panels 565.9 V 22 panels
0 C (32 F) 42.27 V 14 panels 591.8 V 23 panels
25 C (77 F STC) 39.1 V 15 panels 586.5 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to Solartech Energy ASC-6M-60A-275-3BB?

Competing CEC solar panels closest to Solartech Energy ASC-6M-60A-275-3BB in nameplate wattage and Voc, starting with Centrosolar America DM60 275.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DM60 275
Centrosolar America
275.0 W Tie (0 W) 39.1 V 16.77% 90.9%
Flextronics FXS-275BB-SAC1B
Flextronics
275.0 W Tie (0 W) 38.6 V 16.75% 91.4%
AXITEC AC-275P/60S
AXITEC
275.0 W Tie (0 W) 38.5 V 16.87% 92.2%
AXITEC AC-275P/60V
AXITEC
275.0 W Tie (0 W) 38.5 V 16.87% 92.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Solartech Energy ASC-6M-60A-275-3BB?

Evaluate Solartech Energy ASC-6M-60A-275-3BB (275.0 W STC, 39.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Solartech Energy ASC-6M-60A-275-3BB reaches 44.8 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 530 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (530 sq ft).
  • 2026 tax credit baseline: cash residential installs of Solartech Energy ASC-6M-60A-275-3BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Solartech Energy ASC-6M-60A-275-3BB 8 kW Residential Fit

Needs 30 modules (530 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America DM60 275.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 250.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solartech Energy ASC-6M-60A-275-3BB by Solartech Energy grounded in CEC test data and NEC 690.7/690.8 limits.

How many Solartech Energy ASC-6M-60A-275-3BB panels fit on a 600 V winter solar string?

At -10 C (14 F), Solartech Energy ASC-6M-60A-275-3BB cold Voc rises from 39.1 V to 43.53 V (beta_Voc -0.324%/C), capping a 600 V string at 13 panels (565.9 V).

How much roof area does an 8 kW array of Solartech Energy ASC-6M-60A-275-3BB need?

An 8 kW DC system uses 30 Solartech Energy ASC-6M-60A-275-3BB modules (8,250 W STC / 7,500 W PTC), covering roughly 530 sq ft and saving ~$2,065/yr at 18.54 c/kWh.

How does Solartech Energy ASC-6M-60A-275-3BB compare against Centrosolar America DM60 275?

Solartech Energy ASC-6M-60A-275-3BB outputs 275.0 W STC (39.1 V Voc, rank #18,259 of 21,677), while Centrosolar America DM60 275 delivers 275.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.