Skip to main content
WireAndSun
Calculators
CEC PV Module

Solaria Corporation Solaria PowerXT-420R-PM — CEC Solar Module Specifications

Manufacturer: Solaria Corporation Registry: CEC Verified Engineering Specification

Solaria Corporation Solaria PowerXT-420R-PM is a 420.0 W STC (383.0 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 21.21% efficiency, 52.4 V Voc at 25 C, and 58.4 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
420.0 W
PTC Wattage
383.0 W
Voc @ 25C
52.4 V
Efficiency
21.21%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Solaria Corporation Solaria PowerXT-420R-PM Compare Against Peer CEC Listings?

How Solaria Corporation Solaria Corporation Solaria PowerXT-420R-PM handles rooftop heat (383.0 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Solaria Corporation Solaria PowerXT-420R-PM exhibits 9.94 A short-circuit current, requiring a 15.51 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #7,910 of 21,677 (10.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 39.6 m2 for an 8 kW system (24 panels for 10 kW). Higher 52.4 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does Solaria Corporation Solaria PowerXT-420R-PM Fall Across Listed CEC Models?

Where Solaria Corporation Solaria PowerXT-420R-PM (420.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Solaria Corporation Solaria PowerXT-420R-PM (420.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSolaria Corporatio: 420.0 W

What Dataset Percentiles Define Solaria Corporation Solaria PowerXT-420R-PM?

Percentile placement of Solaria Corporation Solaria PowerXT-420R-PM across power density (212.1 W/m2), thermal retention, and nameplate STC wattage.

Solaria Corporation Solaria PowerXT-420R-PM Engineering BenchmarksPercentile comparison of Solaria Corporation Solaria PowerXT-420R-PM wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage420.0 WPTC/STC Retention91.2%Module Efficiency21.21%

What Do the Dataset Ranks Show for Solaria Corporation Solaria PowerXT-420R-PM?

Four critical engineering numbers homeowners and solar installers check first when reviewing Solaria Corporation Solaria PowerXT-420R-PM specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Rank #7,910 / 21,677

Top 37.8% STC Output

420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,556

21.21% Aperture Efficiency

Power density 212.1 W/m2 (1.30 percentage points above 19.91% CEC median). PTC/STC ratio: 91.2% (rank #16,270).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 58.4 V at -10 C (584.0 V string) and 60.11 V at -20 C (9 max).

8 kW Reference Array

20 Panels = 8,400 W STC

Occupies 39.6 m2 (426 sq ft) producing 7,660 W PTC; NEC 690.8 OCPD floor is 15.51 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 52.4 * (1 + (-0.327/100) * (-10 - 25)) = 58.4 V | OCPD = 1.56 * 9.94 = 15.51 A

Inputs from CEC Modules.csv for Solaria Corporation Solaria PowerXT-420R-PM: Voc=52.4 V, beta_Voc=-0.327%/C, Isc=9.94 A, STC=420.0 W, Area=1.98 m2.

Result: 10 panels max on 600 V (584.0 V); 20 panels for 8 kW (426 sq ft).

What Are the Published CEC Specifications for Solaria Corporation Solaria PowerXT-420R-PM?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Solaria Corporation Solaria PowerXT-420R-PM.

Official California Energy Commission (NREL SAM) test parameters for Solaria Corporation Solaria PowerXT-420R-PM.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 420.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 383.0 W (91.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 52.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.94 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 43.8 V / 9.6 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.327 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.21% (1.98 m2) Array roof footprint density
Cell Count & Technology 380 cells (Mono-c-Si) Monofacial backsheet

How Many Solaria Corporation Solaria PowerXT-420R-PM Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Solaria Corporation Solaria PowerXT-420R-PM (420.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.3 kW 320 sq ft $1,577 $2,666
8 kW Class 20 8.4 kW 426 sq ft $2,102 $3,555
10 kW Class 24 10.08 kW 512 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Solaria Corporation Series?

All closely matched Solaria Corporation wattages and cosmetic trims sharing the Solaria Corporation Solaria PowerXT-420R-PM architecture. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the Solaria Corporation Solaria PowerXT-420R-PM wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Solaria Corporation Solaria PowerXT-410R-PM 410.0 W 373.6 W 51.7 V 43.2 V 20.71%
Solaria Corporation Solaria PowerXT-420R-PM 420.0 W 383.0 W 52.4 V 43.8 V 21.21%

How Many Solaria Corporation Solaria PowerXT-420R-PM Modules Fit in a Cold-Weather String?

Maximum series module counts for Solaria Corporation Solaria PowerXT-420R-PM from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=52.4V and beta_Voc=-0.327%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 60.11 V 9 panels 541.0 V 16 panels
-10 C (14 F) 58.4 V 10 panels 584.0 V 17 panels
0 C (32 F) 56.68 V 10 panels 566.8 V 17 panels
25 C (77 F STC) 52.4 V 11 panels 576.4 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to Solaria Corporation Solaria PowerXT-420R-PM?

Alternative CEC solar modules from competing brands near Solaria Corporation Solaria PowerXT-420R-PM (420.0 W), including CSI Solar Co Ltd CS1Y-410MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS1Y-410MS
CSI Solar Co Ltd
410.0 W -10.0 W 52.7 V 21.03% 94.1%
DualSun SAS DualSun 420M-144-01
DualSun SAS
420.0 W Tie (0 W) 48.8 V 19.44% 93.8%
Auxin Solar AXNG1M410B
Auxin Solar
410.0 W -10.0 W 49.47 V 20.92% 93.4%
Auxin Solar AXNG1M410W
Auxin Solar
410.0 W -10.0 W 49.47 V 20.92% 93.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Solaria Corporation Solaria PowerXT-420R-PM?

Evaluate Solaria Corporation Solaria PowerXT-420R-PM (420.0 W STC, 52.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Solaria Corporation Solaria PowerXT-420R-PM reaches 60.11 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 426 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (426 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Solaria Corporation Solaria PowerXT-420R-PM carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Solaria Corporation Solaria PowerXT-420R-PM 8 kW Residential Fit

Needs 20 modules (426 sq ft) with a 20 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 9 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-410MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 383.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solaria Corporation Solaria PowerXT-420R-PM by Solaria Corporation grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Solaria Corporation Solaria PowerXT-420R-PM PTC wattage (383.0 W) lower than STC (420.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 383.0 W PTC (91.2% retention) across Solaria Corporation Solaria PowerXT-420R-PM's 1.98 m2 aperture.

Who should skip Solaria Corporation Solaria PowerXT-420R-PM on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 Solaria Corporation Solaria PowerXT-420R-PM panels (426 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS1Y-410MS.

What is the 1,000 V commercial string limit for Solaria Corporation Solaria PowerXT-420R-PM?

On 1,000 V commercial inverters at -10 C (58.4 V cold Voc), Solaria Corporation Solaria PowerXT-420R-PM fits up to 17 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Solaria Corporation Solaria PowerXT-420R-PM.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.