Solaria Corporation PowerXT-430R-PL is a 430.0 W STC (394.6 W PTC) Mono-c-Si solar module ranking #7,266 of 21,677 CEC listings (top 35.2%; higher than 64.8% of peers). It delivers 20.48% efficiency, 45.7 V Voc at 25 C, and 50.37 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 430.0 W
- PTC Wattage
- 394.6 W
- Voc @ 25C
- 45.7 V
- Efficiency
- 20.48%
How Does Solaria Corporation PowerXT-430R-PL Compare Against Peer CEC Listings?
How Solaria Corporation Solaria Corporation PowerXT-430R-PL handles rooftop heat (394.6 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Solaria Corporation PowerXT-430R-PL exhibits 11.87 A short-circuit current, requiring a 18.52 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #7,266 of 21,677 (20.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 39.9 m2 for an 8 kW system (24 panels for 10 kW). Mid-range 45.7 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.
Where Does Solaria Corporation PowerXT-430R-PL Fall Across Listed CEC Models?
Where Solaria Corporation PowerXT-430R-PL (430.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Solaria Corporation PowerXT-430R-PL?
Percentile placement of Solaria Corporation PowerXT-430R-PL across power density (204.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Solaria Corporation PowerXT-430R-PL?
Four critical engineering numbers homeowners and solar installers check first when reviewing Solaria Corporation PowerXT-430R-PL specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
Top 35.2% STC Output
430.0 W STC (+45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.48% Aperture Efficiency
Power density 204.8 W/m2 (0.57 percentage points above 19.91% CEC median). PTC/STC ratio: 91.8% (rank #14,745).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.37 V at -10 C (554.1 V string) and 51.7 V at -20 C (11 max).
19 Panels = 8,170 W STC
Occupies 39.9 m2 (429 sq ft) producing 7,497 W PTC; NEC 690.8 OCPD floor is 18.52 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.7 * (1 + (-0.292/100) * (-10 - 25)) = 50.37 V | OCPD = 1.56 * 11.87 = 18.52 A
Inputs from CEC Modules.csv for Solaria Corporation PowerXT-430R-PL: Voc=45.7 V, beta_Voc=-0.292%/C, Isc=11.87 A, STC=430.0 W, Area=2.1 m2.
Result: 11 panels max on 600 V (554.1 V); 19 panels for 8 kW (429 sq ft).
What Are the Published CEC Specifications for Solaria Corporation PowerXT-430R-PL?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Solaria Corporation PowerXT-430R-PL.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 430.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 394.6 W (91.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.87 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.9 V / 11.35 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.292 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.48% (2.1 m2) | Array roof footprint density |
| Cell Count & Technology | 68 cells (Mono-c-Si) | Monofacial backsheet |
How Many Solaria Corporation PowerXT-430R-PL Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Solaria Corporation PowerXT-430R-PL (430.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.02 kW | 316 sq ft | $1,507 | $2,548 |
| 8 kW Class | 19 | 8.17 kW | 429 sq ft | $2,045 | $3,458 |
| 10 kW Class | 24 | 10.32 kW | 543 sq ft | $2,583 | $4,368 |
Which Sibling Wattage & Trim Variants Belong to This Solaria Corporation Series?
All closely matched Solaria Corporation wattages and cosmetic trims sharing the Solaria Corporation PowerXT-430R-PL architecture. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Solaria Corporation PowerXT-425R-PL | 425.0 W | 389.8 W | 45.7 V | 37.9 V | 20.24% |
| Solaria Corporation PowerXT-430R-PL | 430.0 W | 394.6 W | 45.7 V | 37.9 V | 20.48% |
How Many Solaria Corporation PowerXT-430R-PL Modules Fit in a Cold-Weather String?
Maximum series module counts for Solaria Corporation PowerXT-430R-PL from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.7 V | 11 panels | 568.7 V | 19 panels |
| -10 C (14 F) | 50.37 V | 11 panels | 554.1 V | 19 panels |
| 0 C (32 F) | 49.04 V | 12 panels | 588.5 V | 20 panels |
| 25 C (77 F STC) | 45.7 V | 13 panels | 594.1 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Solaria Corporation PowerXT-430R-PL?
Alternative CEC solar modules from competing brands near Solaria Corporation PowerXT-430R-PL (430.0 W), including CSI Solar Co Ltd CS3N-430MS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3N-430MS CSI Solar Co Ltd |
430.0 W | Tie (0 W) | 45.7 V | 21.83% | 93.7% |
| DualSun SAS DSTN425M12-B320SBB7 DualSun SAS |
425.0 W | -5.0 W | 43.4 V | 21.04% | 87.7% |
| Boviet Solar Technology Co Ltd BVM6612M-435S-H-HC Boviet Solar Technology Co Ltd |
435.0 W | +5.0 W | 48.45 V | 19.77% | 93.7% |
| CSI Solar Co Ltd CS3W-435P CSI Solar Co Ltd |
435.0 W | +5.0 W | 48.6 V | 20.33% | 92.4% |
What Are the Design Limits and Best-Fit Uses for Solaria Corporation PowerXT-430R-PL?
Evaluate Solaria Corporation PowerXT-430R-PL (430.0 W STC, 45.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Solaria Corporation PowerXT-430R-PL reaches 51.7 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 429 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (429 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Solaria Corporation PowerXT-430R-PL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Solaria Corporation PowerXT-430R-PL 8 kW Residential Fit
Needs 19 modules (429 sq ft) with a 20 A string OCPD, offsetting ~$2,045/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3N-430MS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 394.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Solaria Corporation PowerXT-430R-PL by Solaria Corporation grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Solaria Corporation PowerXT-430R-PL PTC wattage (394.6 W) lower than STC (430.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 394.6 W PTC (91.8% retention) across Solaria Corporation PowerXT-430R-PL's 2.1 m2 aperture.
Who should skip Solaria Corporation PowerXT-430R-PL on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 Solaria Corporation PowerXT-430R-PL panels (429 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3N-430MS.
What is the 1,000 V commercial string limit for Solaria Corporation PowerXT-430R-PL?
On 1,000 V commercial inverters at -10 C (50.37 V cold Voc), Solaria Corporation PowerXT-430R-PL fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Solaria Corporation PowerXT-430R-PL.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)