Solaria Corporation PowerX-405R-4T is a 405.0 W STC (375.8 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 19.29% efficiency, 37.1 V Voc at 25 C, and 40.76 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 405.0 W
- PTC Wattage
- 375.8 W
- Voc @ 25C
- 37.1 V
- Efficiency
- 19.29%
How Does Solaria Corporation PowerX-405R-4T Compare Against Peer CEC Listings?
Solar engineering breakdown for Solaria Corporation PowerX-405R-4T: PTC thermal retention, roof footprint, and cold Voc string bounds. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
Across 5,889 Mono-c-Si listings from Solaria Corporation and peers, Solaria Corporation PowerX-405R-4T stands 5.0 W below the 410.0 W Mono-c-Si median and strong 92.8% PTC-to-STC heat retention (#10,898 of 21,677). Sizing 6 kW (15 panels) to 10 kW (25 panels) yields $1,522-$2,533/yr in baseline US bill offset. Lower 37.1 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Solaria Corporation PowerX-405R-4T Fall Across Listed CEC Models?
Distribution marker showing Solaria Corporation PowerX-405R-4T (405.0 W) relative to the 385.0 W all-CEC solar panel median. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Dataset Percentiles Define Solaria Corporation PowerX-405R-4T?
Dataset percentiles tracking Solaria Corporation PowerX-405R-4T power output, thermal retention ratio, and aperture efficiency against 21,677 models. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Do the Dataset Ranks Show for Solaria Corporation PowerX-405R-4T?
Benchmark highlights for Solaria Corporation PowerX-405R-4T covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
Top 43.4% STC Output
405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.29% Aperture Efficiency
Power density 192.9 W/m2 (0.62 percentage points below 19.91% CEC median). PTC/STC ratio: 92.8% (rank #10,898).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.76 V at -10 C (570.6 V string) and 41.81 V at -20 C (14 max).
20 Panels = 8,100 W STC
Occupies 42.0 m2 (452 sq ft) producing 7,516 W PTC; NEC 690.8 OCPD floor is 21.03 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.1 * (1 + (-0.282/100) * (-10 - 25)) = 40.76 V | OCPD = 1.56 * 13.48 = 21.03 A
Inputs from CEC Modules.csv for Solaria Corporation PowerX-405R-4T: Voc=37.1 V, beta_Voc=-0.282%/C, Isc=13.48 A, STC=405.0 W, Area=2.1 m2.
Result: 14 panels max on 600 V (570.6 V); 20 panels for 8 kW (452 sq ft).
What Are the Published CEC Specifications for Solaria Corporation PowerX-405R-4T?
Official CEC datasheet figures for Solaria Corporation PowerX-405R-4T (Mono-c-Si) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 405.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 375.8 W (92.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.48 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.85 V / 12.33 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.282 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.29% (2.1 m2) | Array roof footprint density |
| Cell Count & Technology | 12 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Solaria Corporation PowerX-405R-4T Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Solaria Corporation PowerX-405R-4T modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.08 kW | 339 sq ft | $1,522 | $2,573 |
| 8 kW Class | 20 | 8.1 kW | 452 sq ft | $2,027 | $3,428 |
| 10 kW Class | 25 | 10.12 kW | 565 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This Solaria Corporation Series?
Consolidated Solaria Corporation wattage variants sharing the Solaria Corporation PowerX-405R-4T mechanical and cell layout. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Solaria Corporation PowerX-400R-4T | 400.0 W | 371.0 W | 37.04 V | 32.69 V | 19.05% |
| Solaria Corporation PowerX-405R-4T | 405.0 W | 375.8 W | 37.1 V | 32.85 V | 19.29% |
How Many Solaria Corporation PowerX-405R-4T Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Solaria Corporation PowerX-405R-4T (40.76 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.81 V | 14 panels | 585.3 V | 23 panels |
| -10 C (14 F) | 40.76 V | 14 panels | 570.6 V | 24 panels |
| 0 C (32 F) | 39.72 V | 15 panels | 595.8 V | 25 panels |
| 25 C (77 F STC) | 37.1 V | 16 panels | 593.6 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Solaria Corporation PowerX-405R-4T?
Competing CEC solar panels closest to Solaria Corporation PowerX-405R-4T in nameplate wattage and Voc, starting with ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS ALTERNATIVE ENERGY (AE) SOLAR CO LTD |
405.0 W | Tie (0 W) | 37.2 V | 20.98% | 93.4% |
| AXITEC AC-405MBT/108V AXITEC |
405.0 W | Tie (0 W) | 37.2 V | 20.98% | 93.4% |
| Aptos Solar Technology LLC DNA-108-BF10-405W Aptos Solar Technology LLC |
405.0 W | Tie (0 W) | 37.23 V | 20.98% | 93.3% |
| Dehui Solar Power (Vietnam) CoLtd DH-M154T 405W Dehui Solar Power (Vietnam) CoLtd |
405.0 W | Tie (0 W) | 37.23 V | 20.98% | 93.3% |
What Are the Design Limits and Best-Fit Uses for Solaria Corporation PowerX-405R-4T?
Evaluate Solaria Corporation PowerX-405R-4T (405.0 W STC, 37.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Solaria Corporation PowerX-405R-4T reaches 41.81 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 452 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (452 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Solaria Corporation PowerX-405R-4T carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Solaria Corporation PowerX-405R-4T 8 kW Residential Fit
Needs 20 modules (452 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 375.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Solaria Corporation PowerX-405R-4T by Solaria Corporation grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Solaria Corporation PowerX-405R-4T?
Multiplying Solaria Corporation PowerX-405R-4T's 13.48 A short-circuit current by 1.56 equals 21.03 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Solaria Corporation PowerX-405R-4T pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 40.76 V cold Voc at 14 F and handles 13.48 A Isc; string inverters cap Solaria Corporation PowerX-405R-4T at 14 panels on 600 V.
Is Solaria Corporation PowerX-405R-4T eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Solaria Corporation PowerX-405R-4T rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)