Skip to main content
WireAndSun
Calculators
CEC PV Module

Solaria Corporation Solaria PowerXT-375R-PD — CEC Solar Module Specifications

Manufacturer: Solaria Corporation Registry: CEC Verified Engineering Specification

Solaria Corporation Solaria PowerXT-375R-PD is a 375.0 W STC (339.2 W PTC) Mono-c-Si solar module ranking #11,367 of 21,677 CEC listings (below all-CEC median; higher than 46.0% of peers). It delivers 20.72% efficiency, 48.7 V Voc at 25 C, and 54.21 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
375.0 W
PTC Wattage
339.2 W
Voc @ 25C
48.7 V
Efficiency
20.72%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Solaria Corporation Solaria PowerXT-375R-PD Compare Against Peer CEC Listings?

How Solaria Corporation Solaria Corporation Solaria PowerXT-375R-PD handles rooftop heat (339.2 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Solaria Corporation Solaria PowerXT-375R-PD exhibits 9.65 A short-circuit current, requiring a 15.05 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #11,367 of 21,677 (35.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 39.8 m2 for an 8 kW system (27 panels for 10 kW). Higher 48.7 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does Solaria Corporation Solaria PowerXT-375R-PD Fall Across Listed CEC Models?

Where Solaria Corporation Solaria PowerXT-375R-PD (375.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Solaria Corporation Solaria PowerXT-375R-PD (375.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSolaria Corporatio: 375.0 W

What Dataset Percentiles Define Solaria Corporation Solaria PowerXT-375R-PD?

Percentile placement of Solaria Corporation Solaria PowerXT-375R-PD across power density (207.2 W/m2), thermal retention, and nameplate STC wattage.

Solaria Corporation Solaria PowerXT-375R-PD Engineering BenchmarksPercentile comparison of Solaria Corporation Solaria PowerXT-375R-PD wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage375.0 WPTC/STC Retention90.5%Module Efficiency20.72%

What Do the Dataset Ranks Show for Solaria Corporation Solaria PowerXT-375R-PD?

Four critical engineering numbers homeowners and solar installers check first when reviewing Solaria Corporation Solaria PowerXT-375R-PD specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Rank #11,367 / 21,677

375.0 W STC · Higher Than 46.0%

375.0 W STC (-10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,646

20.72% Aperture Efficiency

Power density 207.2 W/m2 (0.81 percentage points above 19.91% CEC median). PTC/STC ratio: 90.5% (rank #17,786).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.21 V at -10 C (596.3 V string) and 55.78 V at -20 C (10 max).

8 kW Reference Array

22 Panels = 8,250 W STC

Occupies 39.8 m2 (429 sq ft) producing 7,462 W PTC; NEC 690.8 OCPD floor is 15.05 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.7 * (1 + (-0.323/100) * (-10 - 25)) = 54.21 V | OCPD = 1.56 * 9.65 = 15.05 A

Inputs from CEC Modules.csv for Solaria Corporation Solaria PowerXT-375R-PD: Voc=48.7 V, beta_Voc=-0.323%/C, Isc=9.65 A, STC=375.0 W, Area=1.81 m2.

Result: 11 panels max on 600 V (596.3 V); 22 panels for 8 kW (429 sq ft).

What Are the Published CEC Specifications for Solaria Corporation Solaria PowerXT-375R-PD?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Solaria Corporation Solaria PowerXT-375R-PD.

Official California Energy Commission (NREL SAM) test parameters for Solaria Corporation Solaria PowerXT-375R-PD.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 375.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 339.2 W (90.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.65 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.6 V / 9.24 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.323 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.72% (1.81 m2) Array roof footprint density
Cell Count & Technology 36 cells (Mono-c-Si) Monofacial backsheet

How Many Solaria Corporation Solaria PowerXT-375R-PD Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Solaria Corporation Solaria PowerXT-375R-PD (375.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.0 kW 312 sq ft $1,502 $2,539
8 kW Class 22 8.25 kW 429 sq ft $2,065 $3,492
10 kW Class 27 10.12 kW 526 sq ft $2,533 $4,283

How Many Solaria Corporation Solaria PowerXT-375R-PD Modules Fit in a Cold-Weather String?

Maximum series module counts for Solaria Corporation Solaria PowerXT-375R-PD from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=48.7V and beta_Voc=-0.323%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.78 V 10 panels 557.8 V 17 panels
-10 C (14 F) 54.21 V 11 panels 596.3 V 18 panels
0 C (32 F) 52.63 V 11 panels 578.9 V 19 panels
25 C (77 F STC) 48.7 V 12 panels 584.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Solaria Corporation Solaria PowerXT-375R-PD?

Alternative CEC solar modules from competing brands near Solaria Corporation Solaria PowerXT-375R-PD (375.0 W), including CertainTeed CT375M00-04. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CertainTeed CT375M00-04
CertainTeed
375.0 W Tie (0 W) 48.2 V 19.93% 93.3%
AXITEC AC-375M/72S
AXITEC
375.0 W Tie (0 W) 48.16 V 19.33% 91.3%
AXITEC AC-375M/72V
AXITEC
375.0 W Tie (0 W) 48.16 V 19.33% 91.3%
Boviet Solar Technology Co Ltd BVM6612M-375
Boviet Solar Technology Co Ltd
375.0 W Tie (0 W) 48.0 V 19.33% 92.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Solaria Corporation Solaria PowerXT-375R-PD?

Evaluate Solaria Corporation Solaria PowerXT-375R-PD (375.0 W STC, 48.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Solaria Corporation Solaria PowerXT-375R-PD reaches 55.78 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 429 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (429 sq ft).
  • 2026 tax credit baseline: cash residential installs of Solaria Corporation Solaria PowerXT-375R-PD carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Solaria Corporation Solaria PowerXT-375R-PD 8 kW Residential Fit

Needs 22 modules (429 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare CertainTeed CT375M00-04.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 339.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solaria Corporation Solaria PowerXT-375R-PD by Solaria Corporation grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Solaria Corporation Solaria PowerXT-375R-PD PTC wattage (339.2 W) lower than STC (375.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 339.2 W PTC (90.5% retention) across Solaria Corporation Solaria PowerXT-375R-PD's 1.81 m2 aperture.

Who should skip Solaria Corporation Solaria PowerXT-375R-PD on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 Solaria Corporation Solaria PowerXT-375R-PD panels (429 sq ft) leave unusable roof gaps vs. CertainTeed CT375M00-04.

What is the 1,000 V commercial string limit for Solaria Corporation Solaria PowerXT-375R-PD?

On 1,000 V commercial inverters at -10 C (54.21 V cold Voc), Solaria Corporation Solaria PowerXT-375R-PD fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Solaria Corporation Solaria PowerXT-375R-PD.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.