Solaria Corporation Solaria PowerXT-375R-PD is a 375.0 W STC (339.2 W PTC) Mono-c-Si solar module ranking #11,367 of 21,677 CEC listings (below all-CEC median; higher than 46.0% of peers). It delivers 20.72% efficiency, 48.7 V Voc at 25 C, and 54.21 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 375.0 W
- PTC Wattage
- 339.2 W
- Voc @ 25C
- 48.7 V
- Efficiency
- 20.72%
How Does Solaria Corporation Solaria PowerXT-375R-PD Compare Against Peer CEC Listings?
How Solaria Corporation Solaria Corporation Solaria PowerXT-375R-PD handles rooftop heat (339.2 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Solaria Corporation Solaria PowerXT-375R-PD exhibits 9.65 A short-circuit current, requiring a 15.05 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #11,367 of 21,677 (35.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 39.8 m2 for an 8 kW system (27 panels for 10 kW). Higher 48.7 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does Solaria Corporation Solaria PowerXT-375R-PD Fall Across Listed CEC Models?
Where Solaria Corporation Solaria PowerXT-375R-PD (375.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Solaria Corporation Solaria PowerXT-375R-PD?
Percentile placement of Solaria Corporation Solaria PowerXT-375R-PD across power density (207.2 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Solaria Corporation Solaria PowerXT-375R-PD?
Four critical engineering numbers homeowners and solar installers check first when reviewing Solaria Corporation Solaria PowerXT-375R-PD specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
375.0 W STC · Higher Than 46.0%
375.0 W STC (-10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.72% Aperture Efficiency
Power density 207.2 W/m2 (0.81 percentage points above 19.91% CEC median). PTC/STC ratio: 90.5% (rank #17,786).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.21 V at -10 C (596.3 V string) and 55.78 V at -20 C (10 max).
22 Panels = 8,250 W STC
Occupies 39.8 m2 (429 sq ft) producing 7,462 W PTC; NEC 690.8 OCPD floor is 15.05 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.7 * (1 + (-0.323/100) * (-10 - 25)) = 54.21 V | OCPD = 1.56 * 9.65 = 15.05 A
Inputs from CEC Modules.csv for Solaria Corporation Solaria PowerXT-375R-PD: Voc=48.7 V, beta_Voc=-0.323%/C, Isc=9.65 A, STC=375.0 W, Area=1.81 m2.
Result: 11 panels max on 600 V (596.3 V); 22 panels for 8 kW (429 sq ft).
What Are the Published CEC Specifications for Solaria Corporation Solaria PowerXT-375R-PD?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Solaria Corporation Solaria PowerXT-375R-PD.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 375.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 339.2 W (90.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.65 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.6 V / 9.24 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.323 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.72% (1.81 m2) | Array roof footprint density |
| Cell Count & Technology | 36 cells (Mono-c-Si) | Monofacial backsheet |
How Many Solaria Corporation Solaria PowerXT-375R-PD Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Solaria Corporation Solaria PowerXT-375R-PD (375.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.0 kW | 312 sq ft | $1,502 | $2,539 |
| 8 kW Class | 22 | 8.25 kW | 429 sq ft | $2,065 | $3,492 |
| 10 kW Class | 27 | 10.12 kW | 526 sq ft | $2,533 | $4,283 |
How Many Solaria Corporation Solaria PowerXT-375R-PD Modules Fit in a Cold-Weather String?
Maximum series module counts for Solaria Corporation Solaria PowerXT-375R-PD from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.78 V | 10 panels | 557.8 V | 17 panels |
| -10 C (14 F) | 54.21 V | 11 panels | 596.3 V | 18 panels |
| 0 C (32 F) | 52.63 V | 11 panels | 578.9 V | 19 panels |
| 25 C (77 F STC) | 48.7 V | 12 panels | 584.4 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Solaria Corporation Solaria PowerXT-375R-PD?
Alternative CEC solar modules from competing brands near Solaria Corporation Solaria PowerXT-375R-PD (375.0 W), including CertainTeed CT375M00-04. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CertainTeed CT375M00-04 CertainTeed |
375.0 W | Tie (0 W) | 48.2 V | 19.93% | 93.3% |
| AXITEC AC-375M/72S AXITEC |
375.0 W | Tie (0 W) | 48.16 V | 19.33% | 91.3% |
| AXITEC AC-375M/72V AXITEC |
375.0 W | Tie (0 W) | 48.16 V | 19.33% | 91.3% |
| Boviet Solar Technology Co Ltd BVM6612M-375 Boviet Solar Technology Co Ltd |
375.0 W | Tie (0 W) | 48.0 V | 19.33% | 92.4% |
What Are the Design Limits and Best-Fit Uses for Solaria Corporation Solaria PowerXT-375R-PD?
Evaluate Solaria Corporation Solaria PowerXT-375R-PD (375.0 W STC, 48.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Solaria Corporation Solaria PowerXT-375R-PD reaches 55.78 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 429 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (429 sq ft).
- 2026 tax credit baseline: cash residential installs of Solaria Corporation Solaria PowerXT-375R-PD carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Solaria Corporation Solaria PowerXT-375R-PD 8 kW Residential Fit
Needs 22 modules (429 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare CertainTeed CT375M00-04.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 339.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Solaria Corporation Solaria PowerXT-375R-PD by Solaria Corporation grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Solaria Corporation Solaria PowerXT-375R-PD PTC wattage (339.2 W) lower than STC (375.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 339.2 W PTC (90.5% retention) across Solaria Corporation Solaria PowerXT-375R-PD's 1.81 m2 aperture.
Who should skip Solaria Corporation Solaria PowerXT-375R-PD on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 Solaria Corporation Solaria PowerXT-375R-PD panels (429 sq ft) leave unusable roof gaps vs. CertainTeed CT375M00-04.
What is the 1,000 V commercial string limit for Solaria Corporation Solaria PowerXT-375R-PD?
On 1,000 V commercial inverters at -10 C (54.21 V cold Voc), Solaria Corporation Solaria PowerXT-375R-PD fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Solaria Corporation Solaria PowerXT-375R-PD.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)