Solaria Corporation Solaria PowerXT-340R-BD is a 340.0 W STC (308.8 W PTC) Mono-c-Si solar module ranking #13,575 of 21,677 CEC listings (below all-CEC median; higher than 36.1% of peers). It delivers 18.78% efficiency, 46.9 V Voc at 25 C, and 51.97 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 340.0 W
- PTC Wattage
- 308.8 W
- Voc @ 25C
- 46.9 V
- Efficiency
- 18.78%
How Does Solaria Corporation Solaria PowerXT-340R-BD Compare Against Peer CEC Listings?
Solar engineering breakdown for Solaria Corporation Solaria PowerXT-340R-BD: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Solaria Corporation and peers, Solaria Corporation Solaria PowerXT-340R-BD stands 70.0 W below the 410.0 W Mono-c-Si median and typical 90.8% PTC-to-STC thermal output (308.8 W real-world rating). Sizing 6 kW (18 panels) to 10 kW (30 panels) yields $1,532-$2,553/yr in baseline US bill offset. Mid-range 46.9 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.
Where Does Solaria Corporation Solaria PowerXT-340R-BD Fall Across Listed CEC Models?
Distribution marker showing Solaria Corporation Solaria PowerXT-340R-BD (340.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Solaria Corporation Solaria PowerXT-340R-BD?
Dataset percentiles tracking Solaria Corporation Solaria PowerXT-340R-BD power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Solaria Corporation Solaria PowerXT-340R-BD?
Benchmark highlights for Solaria Corporation Solaria PowerXT-340R-BD covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
340.0 W STC · Higher Than 36.1%
340.0 W STC (-45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.78% Aperture Efficiency
Power density 187.8 W/m2 (1.13 percentage points below 19.91% CEC median). PTC/STC ratio: 90.8% (rank #17,104).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.97 V at -10 C (571.7 V string) and 53.42 V at -20 C (11 max).
24 Panels = 8,160 W STC
Occupies 43.4 m2 (468 sq ft) producing 7,411 W PTC; NEC 690.8 OCPD floor is 14.6 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 46.9 * (1 + (-0.309/100) * (-10 - 25)) = 51.97 V | OCPD = 1.56 * 9.36 = 14.6 A
Inputs from CEC Modules.csv for Solaria Corporation Solaria PowerXT-340R-BD: Voc=46.9 V, beta_Voc=-0.309%/C, Isc=9.36 A, STC=340.0 W, Area=1.81 m2.
Result: 11 panels max on 600 V (571.7 V); 24 panels for 8 kW (468 sq ft).
What Are the Published CEC Specifications for Solaria Corporation Solaria PowerXT-340R-BD?
Official CEC datasheet figures for Solaria Corporation Solaria PowerXT-340R-BD (Mono-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 340.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 308.8 W (90.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 46.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.36 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.6 V / 8.79 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.309 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.78% (1.81 m2) | Array roof footprint density |
| Cell Count & Technology | 360 cells (Mono-c-Si) | Monofacial backsheet |
How Many Solaria Corporation Solaria PowerXT-340R-BD Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Solaria Corporation Solaria PowerXT-340R-BD modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 18 | 6.12 kW | 351 sq ft | $1,532 | $2,590 |
| 8 kW Class | 24 | 8.16 kW | 468 sq ft | $2,042 | $3,454 |
| 10 kW Class | 30 | 10.2 kW | 584 sq ft | $2,553 | $4,317 |
Which Sibling Wattage & Trim Variants Belong to This Solaria Corporation Series?
Consolidated Solaria Corporation wattage variants sharing the Solaria Corporation Solaria PowerXT-340R-BD mechanical and cell layout. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Solaria Corporation Solaria PowerXT-335R-BD | 335.0 W | 304.2 W | 46.7 V | 38.4 V | 18.51% |
| Solaria Corporation Solaria PowerXT-340R-BD | 340.0 W | 308.8 W | 46.9 V | 38.6 V | 18.78% |
| Solaria Corporation Solaria PowerXT-345R-BD | 345.0 W | 313.5 W | 47.1 V | 38.9 V | 19.06% |
How Many Solaria Corporation Solaria PowerXT-340R-BD Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Solaria Corporation Solaria PowerXT-340R-BD (51.97 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.42 V | 11 panels | 587.6 V | 18 panels |
| -10 C (14 F) | 51.97 V | 11 panels | 571.7 V | 19 panels |
| 0 C (32 F) | 50.52 V | 11 panels | 555.7 V | 19 panels |
| 25 C (77 F STC) | 46.9 V | 12 panels | 562.8 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Solaria Corporation Solaria PowerXT-340R-BD?
Competing CEC solar panels closest to Solaria Corporation Solaria PowerXT-340R-BD in nameplate wattage and Voc, starting with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-340W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-340W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
340.0 W | Tie (0 W) | 46.91 V | 17.68% | 91.4% |
| Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM340-72 Anhui Rinengzhongtian Semiconductor Development Co Ltd |
340.0 W | Tie (0 W) | 46.97 V | 17.52% | 91.0% |
| Advance Power API-M340 Advance Power |
340.0 W | Tie (0 W) | 47.18 V | 17.53% | 91.7% |
| GCL System Integration Technology Co Ltd GCL-M6/72340 GCL System Integration Technology Co Ltd |
340.0 W | Tie (0 W) | 46.6 V | 17.53% | 90.5% |
What Are the Design Limits and Best-Fit Uses for Solaria Corporation Solaria PowerXT-340R-BD?
Evaluate Solaria Corporation Solaria PowerXT-340R-BD (340.0 W STC, 46.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Solaria Corporation Solaria PowerXT-340R-BD reaches 53.42 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 468 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (468 sq ft).
- 2026 tax credit baseline: cash residential installs of Solaria Corporation Solaria PowerXT-340R-BD carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Solaria Corporation Solaria PowerXT-340R-BD 8 kW Residential Fit
Needs 24 modules (468 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-340W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 308.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Solaria Corporation Solaria PowerXT-340R-BD by Solaria Corporation grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Solaria Corporation Solaria PowerXT-340R-BD?
Multiplying Solaria Corporation Solaria PowerXT-340R-BD's 9.36 A short-circuit current by 1.56 equals 14.6 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Solaria Corporation Solaria PowerXT-340R-BD pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 51.97 V cold Voc at 14 F and handles 9.36 A Isc; string inverters cap Solaria Corporation Solaria PowerXT-340R-BD at 11 panels on 600 V.
Is Solaria Corporation Solaria PowerXT-340R-BD eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Solaria Corporation Solaria PowerXT-340R-BD rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)