Solaria Corporation PowerX-380R-2B is a 380.0 W STC (348.9 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 20.0% efficiency, 36.45 V Voc at 25 C, and 40.34 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 380.0 W
- PTC Wattage
- 348.9 W
- Voc @ 25C
- 36.45 V
- Efficiency
- 20.0%
How Does Solaria Corporation PowerX-380R-2B Compare Against Peer CEC Listings?
How Solaria Corporation Solaria Corporation PowerX-380R-2B handles rooftop heat (348.9 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Solaria Corporation PowerX-380R-2B exhibits 13.34 A short-circuit current, requiring a 20.81 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #11,043 of 21,677 (30.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 41.8 m2 for an 8 kW system (27 panels for 10 kW). Lower 36.45 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Solaria Corporation PowerX-380R-2B Fall Across Listed CEC Models?
Where Solaria Corporation PowerX-380R-2B (380.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Solaria Corporation PowerX-380R-2B?
Percentile placement of Solaria Corporation PowerX-380R-2B across power density (200.0 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Solaria Corporation PowerX-380R-2B?
Four critical engineering numbers homeowners and solar installers check first when reviewing Solaria Corporation PowerX-380R-2B specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
380.0 W STC · Higher Than 47.6%
380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.0% Aperture Efficiency
Power density 200.0 W/m2 (0.09 percentage points above 19.91% CEC median). PTC/STC ratio: 91.8% (rank #14,745).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.34 V at -10 C (564.8 V string) and 41.45 V at -20 C (14 max).
22 Panels = 8,360 W STC
Occupies 41.8 m2 (450 sq ft) producing 7,676 W PTC; NEC 690.8 OCPD floor is 20.81 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.45 * (1 + (-0.305/100) * (-10 - 25)) = 40.34 V | OCPD = 1.56 * 13.34 = 20.81 A
Inputs from CEC Modules.csv for Solaria Corporation PowerX-380R-2B: Voc=36.45 V, beta_Voc=-0.305%/C, Isc=13.34 A, STC=380.0 W, Area=1.9 m2.
Result: 14 panels max on 600 V (564.8 V); 22 panels for 8 kW (450 sq ft).
What Are the Published CEC Specifications for Solaria Corporation PowerX-380R-2B?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Solaria Corporation PowerX-380R-2B.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 380.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 348.9 W (91.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.45 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.34 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.59 V / 12.44 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.305 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.0% (1.9 m2) | Array roof footprint density |
| Cell Count & Technology | 12 cells (Mono-c-Si) | Monofacial backsheet |
How Many Solaria Corporation PowerX-380R-2B Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Solaria Corporation PowerX-380R-2B (380.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.08 kW | 327 sq ft | $1,522 | $2,573 |
| 8 kW Class | 22 | 8.36 kW | 450 sq ft | $2,092 | $3,538 |
| 10 kW Class | 27 | 10.26 kW | 552 sq ft | $2,568 | $4,342 |
How Many Solaria Corporation PowerX-380R-2B Modules Fit in a Cold-Weather String?
Maximum series module counts for Solaria Corporation PowerX-380R-2B from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.45 V | 14 panels | 580.3 V | 24 panels |
| -10 C (14 F) | 40.34 V | 14 panels | 564.8 V | 24 panels |
| 0 C (32 F) | 39.23 V | 15 panels | 588.4 V | 25 panels |
| 25 C (77 F STC) | 36.45 V | 16 panels | 583.2 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to Solaria Corporation PowerX-380R-2B?
Alternative CEC solar modules from competing brands near Solaria Corporation PowerX-380R-2B (380.0 W), including DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW390M.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW390M DONGGUAN SUNWORTH SOLAR ENERGY CO LTD |
390.0 W | +10.0 W | 36.45 V | 20.53% | 94.4% |
| CSI Solar Co Ltd CS6R-390MS-HL {Blk} CSI Solar Co Ltd |
390.0 W | +10.0 W | 36.4 V | 20.0% | 94.1% |
| Apollo Renewables Inc Apollo-M754BH-390BB Apollo Renewables Inc |
390.0 W | +10.0 W | 36.85 V | 20.1% | 93.7% |
| AXITEC AC-390MH/108VB AXITEC |
390.0 W | +10.0 W | 36.85 V | 20.1% | 93.7% |
What Are the Design Limits and Best-Fit Uses for Solaria Corporation PowerX-380R-2B?
Evaluate Solaria Corporation PowerX-380R-2B (380.0 W STC, 36.45 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Solaria Corporation PowerX-380R-2B reaches 41.45 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 450 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (450 sq ft).
- 2026 tax credit baseline: cash residential installs of Solaria Corporation PowerX-380R-2B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Solaria Corporation PowerX-380R-2B 8 kW Residential Fit
Needs 22 modules (450 sq ft) with a 25 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW390M.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 348.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Solaria Corporation PowerX-380R-2B by Solaria Corporation grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Solaria Corporation PowerX-380R-2B PTC wattage (348.9 W) lower than STC (380.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 348.9 W PTC (91.8% retention) across Solaria Corporation PowerX-380R-2B's 1.9 m2 aperture.
Who should skip Solaria Corporation PowerX-380R-2B on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 Solaria Corporation PowerX-380R-2B panels (450 sq ft) leave unusable roof gaps vs. DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW390M.
What is the 1,000 V commercial string limit for Solaria Corporation PowerX-380R-2B?
On 1,000 V commercial inverters at -10 C (40.34 V cold Voc), Solaria Corporation PowerX-380R-2B fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Solaria Corporation PowerX-380R-2B.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)