Skip to main content
WireAndSun
Calculators
CEC PV Module

Solarhome Tech Inc BSM380M-72 — CEC Solar Module Specifications

Manufacturer: Solarhome Tech Inc Registry: CEC Verified Engineering Specification

Solarhome Tech Inc BSM380M-72 is a 380.0 W STC (349.6 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 19.59% efficiency, 48.67 V Voc at 25 C, and 54.36 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
380.0 W
PTC Wattage
349.6 W
Voc @ 25C
48.67 V
Efficiency
19.59%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Solarhome Tech Inc BSM380M-72 Compare Against Peer CEC Listings?

Solar engineering breakdown for Solarhome Tech Inc BSM380M-72: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Solarhome Tech Inc and peers, Solarhome Tech Inc BSM380M-72 stands 30.0 W below the 410.0 W Mono-c-Si median and strong 92.0% PTC-to-STC heat retention (#14,141 of 21,677). Sizing 6 kW (16 panels) to 10 kW (27 panels) yields $1,522-$2,568/yr in baseline US bill offset. Higher 48.67 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does Solarhome Tech Inc BSM380M-72 Fall Across Listed CEC Models?

Distribution marker showing Solarhome Tech Inc BSM380M-72 (380.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Solarhome Tech Inc BSM380M-72 (380.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSolarhome Tech Inc: 380.0 W

What Dataset Percentiles Define Solarhome Tech Inc BSM380M-72?

Dataset percentiles tracking Solarhome Tech Inc BSM380M-72 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Solarhome Tech Inc BSM380M-72 Engineering BenchmarksPercentile comparison of Solarhome Tech Inc BSM380M-72 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage380.0 WPTC/STC Retention92.0%Module Efficiency19.59%

What Do the Dataset Ranks Show for Solarhome Tech Inc BSM380M-72?

Benchmark highlights for Solarhome Tech Inc BSM380M-72 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #11,043 / 21,677

380.0 W STC · Higher Than 47.6%

380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #11,880

19.59% Aperture Efficiency

Power density 195.9 W/m2 (0.32 percentage points below 19.91% CEC median). PTC/STC ratio: 92.0% (rank #14,141).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.36 V at -10 C (598.0 V string) and 55.99 V at -20 C (10 max).

8 kW Reference Array

22 Panels = 8,360 W STC

Occupies 42.7 m2 (459 sq ft) producing 7,691 W PTC; NEC 690.8 OCPD floor is 15.94 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.67 * (1 + (-0.334/100) * (-10 - 25)) = 54.36 V | OCPD = 1.56 * 10.22 = 15.94 A

Inputs from CEC Modules.csv for Solarhome Tech Inc BSM380M-72: Voc=48.67 V, beta_Voc=-0.334%/C, Isc=10.22 A, STC=380.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (598.0 V); 22 panels for 8 kW (459 sq ft).

What Are the Published CEC Specifications for Solarhome Tech Inc BSM380M-72?

Official CEC datasheet figures for Solarhome Tech Inc BSM380M-72 (Mono-c-Si) used in utility interconnection and permit reviews. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for Solarhome Tech Inc BSM380M-72.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 380.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 349.6 W (92.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.67 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.22 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.95 V / 9.52 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.334 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.59% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Solarhome Tech Inc BSM380M-72 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Solarhome Tech Inc BSM380M-72 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.08 kW 334 sq ft $1,522 $2,573
8 kW Class 22 8.36 kW 459 sq ft $2,092 $3,538
10 kW Class 27 10.26 kW 564 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Solarhome Tech Inc Series?

Consolidated Solarhome Tech Inc wattage variants sharing the Solarhome Tech Inc BSM380M-72 mechanical and cell layout. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the Solarhome Tech Inc BSM380M-72 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Solarhome Tech Inc BSM375M-72 375.0 W 344.9 W 48.45 V 39.73 V 19.33%
Solarhome Tech Inc BSM380M-72 380.0 W 349.6 W 48.67 V 39.95 V 19.59%
Solarhome Tech Inc BSM385M-72 385.0 W 354.4 W 48.89 V 40.17 V 19.87%

How Many Solarhome Tech Inc BSM380M-72 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Solarhome Tech Inc BSM380M-72 (54.36 V at 14 F).

Computed from Voc=48.67V and beta_Voc=-0.334%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.99 V 10 panels 559.9 V 17 panels
-10 C (14 F) 54.36 V 11 panels 598.0 V 18 panels
0 C (32 F) 52.73 V 11 panels 580.0 V 18 panels
25 C (77 F STC) 48.67 V 12 panels 584.0 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Solarhome Tech Inc BSM380M-72?

Competing CEC solar panels closest to Solarhome Tech Inc BSM380M-72 in nameplate wattage and Voc, starting with Bluesun Solar Energy Tech CoLtd BSM380M-72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Bluesun Solar Energy Tech CoLtd BSM380M-72
Bluesun Solar Energy Tech CoLtd
380.0 W Tie (0 W) 48.67 V 19.59% 92.0%
Caterpillar Inc PVC380MP03H
Caterpillar Inc
380.0 W Tie (0 W) 49.0 V 19.63% 94.1%
Crossroads Solar Crossroads Solar 380
Crossroads Solar
380.0 W Tie (0 W) 49.0 V 18.63% 92.2%
Caterpillar Inc PVC380MP03
Caterpillar Inc
380.0 W Tie (0 W) 49.03 V 20.21% 93.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Solarhome Tech Inc BSM380M-72?

Evaluate Solarhome Tech Inc BSM380M-72 (380.0 W STC, 48.67 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Solarhome Tech Inc BSM380M-72 reaches 55.99 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 459 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (459 sq ft).
  • 2026 tax credit baseline: cash residential installs of Solarhome Tech Inc BSM380M-72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Solarhome Tech Inc BSM380M-72 8 kW Residential Fit

Needs 22 modules (459 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM380M-72.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 349.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solarhome Tech Inc BSM380M-72 by Solarhome Tech Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Solarhome Tech Inc BSM380M-72?

Multiplying Solarhome Tech Inc BSM380M-72's 10.22 A short-circuit current by 1.56 equals 15.94 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can Solarhome Tech Inc BSM380M-72 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.36 V cold Voc at 14 F and handles 10.22 A Isc; string inverters cap Solarhome Tech Inc BSM380M-72 at 11 panels on 600 V.

Is Solarhome Tech Inc BSM380M-72 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Solarhome Tech Inc BSM380M-72 rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.