Solarhome Tech Inc BSM310M-60 is a 310.0 W STC (285.0 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 19.02% efficiency, 40.18 V Voc at 25 C, and 44.88 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 310.0 W
- PTC Wattage
- 285.0 W
- Voc @ 25C
- 40.18 V
- Efficiency
- 19.02%
How Does Solarhome Tech Inc BSM310M-60 Compare Against Peer CEC Listings?
How Solarhome Tech Inc Solarhome Tech Inc BSM310M-60 handles rooftop heat (285.0 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Solarhome Tech Inc BSM310M-60 exhibits 10.08 A short-circuit current, requiring a 15.72 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #15,760 of 21,677 (100.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 42.4 m2 for an 8 kW system (33 panels for 10 kW). Mid-range 40.18 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.
Where Does Solarhome Tech Inc BSM310M-60 Fall Across Listed CEC Models?
Where Solarhome Tech Inc BSM310M-60 (310.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Solarhome Tech Inc BSM310M-60?
Percentile placement of Solarhome Tech Inc BSM310M-60 across power density (190.2 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Solarhome Tech Inc BSM310M-60?
Four critical engineering numbers homeowners and solar installers check first when reviewing Solarhome Tech Inc BSM310M-60 specifications. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
310.0 W STC · Higher Than 25.6%
310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.02% Aperture Efficiency
Power density 190.2 W/m2 (0.89 percentage points below 19.91% CEC median). PTC/STC ratio: 91.9% (rank #14,464).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.88 V at -10 C (583.4 V string) and 46.22 V at -20 C (12 max).
26 Panels = 8,060 W STC
Occupies 42.4 m2 (456 sq ft) producing 7,410 W PTC; NEC 690.8 OCPD floor is 15.72 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.18 * (1 + (-0.334/100) * (-10 - 25)) = 44.88 V | OCPD = 1.56 * 10.08 = 15.72 A
Inputs from CEC Modules.csv for Solarhome Tech Inc BSM310M-60: Voc=40.18 V, beta_Voc=-0.334%/C, Isc=10.08 A, STC=310.0 W, Area=1.63 m2.
Result: 13 panels max on 600 V (583.4 V); 26 panels for 8 kW (456 sq ft).
What Are the Published CEC Specifications for Solarhome Tech Inc BSM310M-60?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Solarhome Tech Inc BSM310M-60.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 285.0 W (91.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.18 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.08 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.95 V / 9.41 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.334 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.02% (1.63 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Solarhome Tech Inc BSM310M-60 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Solarhome Tech Inc BSM310M-60 (310.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.2 kW | 351 sq ft | $1,552 | $2,624 |
| 8 kW Class | 26 | 8.06 kW | 456 sq ft | $2,017 | $3,411 |
| 10 kW Class | 33 | 10.23 kW | 579 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This Solarhome Tech Inc Series?
All closely matched Solarhome Tech Inc wattages and cosmetic trims sharing the Solarhome Tech Inc BSM310M-60 architecture. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Solarhome Tech Inc BSM300M-60 | 300.0 W | 270.6 W | 39.82 V | 32.51 V | 18.4% |
| Solarhome Tech Inc BSM305M-60 | 305.0 W | 280.2 W | 40.0 V | 32.73 V | 18.71% |
| Solarhome Tech Inc BSM310M-60 | 310.0 W | 285.0 W | 40.18 V | 32.95 V | 19.02% |
| Solarhome Tech Inc BSM315M-60 | 315.0 W | 289.7 W | 40.7 V | 33.2 V | 19.33% |
| Solarhome Tech Inc BSM320M-60 | 320.0 W | 294.4 W | 40.9 V | 33.4 V | 19.63% |
How Many Solarhome Tech Inc BSM310M-60 Modules Fit in a Cold-Weather String?
Maximum series module counts for Solarhome Tech Inc BSM310M-60 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.22 V | 12 panels | 554.6 V | 21 panels |
| -10 C (14 F) | 44.88 V | 13 panels | 583.4 V | 22 panels |
| 0 C (32 F) | 43.54 V | 13 panels | 566.0 V | 22 panels |
| 25 C (77 F STC) | 40.18 V | 14 panels | 562.5 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Solarhome Tech Inc BSM310M-60?
Alternative CEC solar modules from competing brands near Solarhome Tech Inc BSM310M-60 (310.0 W), including Bluesun Solar Energy Tech CoLtd BSM310M-60.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Bluesun Solar Energy Tech CoLtd BSM310M-60 Bluesun Solar Energy Tech CoLtd |
310.0 W | Tie (0 W) | 40.18 V | 19.02% | 91.9% |
| Boviet Solar Technology Co Ltd BVM6610M-310 Boviet Solar Technology Co Ltd |
310.0 W | Tie (0 W) | 40.1 V | 19.05% | 92.2% |
| Boviet Solar Technology Co Ltd BVM6610M-310-H Boviet Solar Technology Co Ltd |
310.0 W | Tie (0 W) | 40.1 V | 19.02% | 93.1% |
| Boviet Solar Technology Co Ltd BVM6610M-W5-310-H Boviet Solar Technology Co Ltd |
310.0 W | Tie (0 W) | 40.1 V | 19.05% | 93.1% |
What Are the Design Limits and Best-Fit Uses for Solarhome Tech Inc BSM310M-60?
Evaluate Solarhome Tech Inc BSM310M-60 (310.0 W STC, 40.18 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Solarhome Tech Inc BSM310M-60 reaches 46.22 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 456 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (456 sq ft).
- 2026 tax credit baseline: cash residential installs of Solarhome Tech Inc BSM310M-60 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Solarhome Tech Inc BSM310M-60 8 kW Residential Fit
Needs 26 modules (456 sq ft) with a 20 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM310M-60.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 285.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Solarhome Tech Inc BSM310M-60 by Solarhome Tech Inc grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Solarhome Tech Inc BSM310M-60 PTC wattage (285.0 W) lower than STC (310.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 285.0 W PTC (91.9% retention) across Solarhome Tech Inc BSM310M-60's 1.63 m2 aperture.
Who should skip Solarhome Tech Inc BSM310M-60 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 26 Solarhome Tech Inc BSM310M-60 panels (456 sq ft) leave unusable roof gaps vs. Bluesun Solar Energy Tech CoLtd BSM310M-60.
What is the 1,000 V commercial string limit for Solarhome Tech Inc BSM310M-60?
On 1,000 V commercial inverters at -10 C (44.88 V cold Voc), Solarhome Tech Inc BSM310M-60 fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Solarhome Tech Inc BSM310M-60.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)