Skip to main content
WireAndSun
Calculators
CEC PV Module

SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} — CEC Solar Module Specifications

Manufacturer: SOLAREVER TECNOLOG A DE AMERICA SA DE CV Registry: CEC Verified Engineering Specification

SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} is a 365.0 W STC (339.9 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 19.84% efficiency, 41.4 V Voc at 25 C, and 45.56 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
365.0 W
PTC Wattage
339.9 W
Voc @ 25C
41.4 V
Efficiency
19.84%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} Compare Against Peer CEC Listings?

Engineering position of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} (365.0 W STC) vs. Caterpillar Inc PVC365MP03HA across 5,889 CEC Mono-c-Si solar modules.

Ranking #12,044 across 21,677 CEC solar panels (below all-CEC median; higher than 42.9% of peers), SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} operates as a compact residential or specialty off-grid module sitting 45.0 W below the 410.0 W Mono-c-Si median. Mid-range 41.4 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F. With strong 93.1% PTC-to-STC heat retention (#9,420 of 21,677), 22 panels occupy 436 sq ft and offset roughly $2,010/yr at average US rates (or $3,398/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} Fall Across Listed CEC Models?

Plots SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} at 365.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} (365.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSOLAREVER TECNOLOG: 365.0 W

What Dataset Percentiles Define SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht}?

Benchmarks SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} on STC wattage, thermal PTC/STC retention, and 19.84 aperture conversion efficiency against CEC peers.

SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} Engineering BenchmarksPercentile comparison of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage365.0 WPTC/STC Retention93.1%Module Efficiency19.84%

What Do the Dataset Ranks Show for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht}?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} by SOLAREVER TECNOLOG A DE AMERICA SA DE CV.

Rank #12,044 / 21,677

365.0 W STC · Higher Than 42.9%

365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #11,093

19.84% Aperture Efficiency

Power density 198.4 W/m2 (0.07 percentage points below 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.56 V at -10 C (592.3 V string) and 46.75 V at -20 C (12 max).

8 kW Reference Array

22 Panels = 8,030 W STC

Occupies 40.5 m2 (436 sq ft) producing 7,478 W PTC; NEC 690.8 OCPD floor is 17.72 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.4 * (1 + (-0.287/100) * (-10 - 25)) = 45.56 V | OCPD = 1.56 * 11.36 = 17.72 A

Inputs from CEC Modules.csv for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht}: Voc=41.4 V, beta_Voc=-0.287%/C, Isc=11.36 A, STC=365.0 W, Area=1.84 m2.

Result: 13 panels max on 600 V (592.3 V); 22 panels for 8 kW (436 sq ft).

What Are the Published CEC Specifications for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht}?

Laboratory test ratings recorded for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht}.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 365.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 339.9 W (93.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.36 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 33.8 V / 10.8 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.287 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.84% (1.84 m2) Array roof footprint density
Cell Count & Technology 40 cells (Mono-c-Si) Monofacial backsheet

How Many SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (436 sq ft at 8 kW), and estimated Year-1 electric bill offset for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht}.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.21 kW 337 sq ft $1,554 $2,628
8 kW Class 22 8.03 kW 436 sq ft $2,010 $3,398
10 kW Class 28 10.22 kW 555 sq ft $2,558 $4,325

Which Sibling Wattage & Trim Variants Belong to This SOLAREVER TECNOLOG A DE AMERICA SA DE CV Series?

Sibling wattage bins and frame colors grouped with SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} under SOLAREVER TECNOLOG A DE AMERICA SA DE CV to prevent duplicate spec pages.

Sibling CEC listings grouped into the SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-355M-120N {Wht} 355.0 W 330.3 W 41.0 V 33.4 V 19.29%
SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-360M-120N {Wht} 360.0 W 335.1 W 41.2 V 33.6 V 19.57%
SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} 365.0 W 339.9 W 41.4 V 33.8 V 19.84%
SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-370M-120N {Wht} 370.0 W 344.7 W 41.6 V 34.0 V 20.11%

How Many SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} (beta_Voc -0.287%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=41.4V and beta_Voc=-0.287%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.75 V 12 panels 561.0 V 21 panels
-10 C (14 F) 45.56 V 13 panels 592.3 V 21 panels
0 C (32 F) 44.37 V 13 panels 576.8 V 22 panels
25 C (77 F STC) 41.4 V 14 panels 579.6 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht}?

Closest cross-brand CEC competitors to SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} matched near 365.0 W STC and 41.4 V Voc, led by Caterpillar Inc PVC365MP03HA.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Caterpillar Inc PVC365MP03HA
Caterpillar Inc
365.0 W Tie (0 W) 41.0 V 20.62% 93.5%
Bluesun Solar CoLtd BSM365M-60HPH
Bluesun Solar CoLtd
365.0 W Tie (0 W) 40.9 V 20.05% 92.8%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
365.0 W Tie (0 W) 40.7 V 20.51% 92.6%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
365.0 W Tie (0 W) 40.7 V 20.17% 92.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht}?

Evaluate SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} (365.0 W STC, 41.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} reaches 46.75 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 436 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (436 sq ft).
  • 2026 tax credit baseline: cash residential installs of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} 8 kW Residential Fit

Needs 22 modules (436 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Caterpillar Inc PVC365MP03HA.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 339.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} by SOLAREVER TECNOLOG A DE AMERICA SA DE CV grounded in CEC test data and NEC 690.7/690.8 limits.

How many SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} panels fit on a 600 V winter solar string?

At -10 C (14 F), SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} cold Voc rises from 41.4 V to 45.56 V (beta_Voc -0.287%/C), capping a 600 V string at 13 panels (592.3 V).

How much roof area does an 8 kW array of SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} need?

An 8 kW DC system uses 22 SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} modules (8,030 W STC / 7,478 W PTC), covering roughly 436 sq ft and saving ~$2,010/yr at 18.54 c/kWh.

How does SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} compare against Caterpillar Inc PVC365MP03HA?

SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht} outputs 365.0 W STC (41.4 V Voc, rank #12,044 of 21,677), while Caterpillar Inc PVC365MP03HA delivers 365.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.