Skip to main content
WireAndSun
Calculators
CEC PV Module

SolarCity Corp SC330 — CEC Solar Module Specifications

Manufacturer: SolarCity Corp Registry: CEC Verified Engineering Specification

SolarCity Corp SC330 is a 330.0 W STC (311.3 W PTC) Multi-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 19.71% efficiency, 69.7 V Voc at 25 C, and 75.8 V cold Voc at -10 C (7 panels max per 600 V string).

STC Wattage
330.0 W
PTC Wattage
311.3 W
Voc @ 25C
69.7 V
Efficiency
19.71%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SolarCity Corp SC330 Compare Against Peer CEC Listings?

Engineering position of SolarCity Corp SC330 (330.0 W STC) vs. Centrosolar America DM72 330 across 1,407 CEC Multi-c-Si solar modules.

Built with 96 Multi-c-Si cells, SolarCity Corp SC330 pairs strong 94.3% PTC-to-STC heat retention (#3,231 of 21,677) with 69.7 V nominal Voc. An 8 kW residential build (8,250 W DC, 7,782 W PTC) saves ~$2,065/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Centrosolar America DM72 330 offers a 330.0 W alternative.

Where Does SolarCity Corp SC330 Fall Across Listed CEC Models?

Plots SolarCity Corp SC330 at 330.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SolarCity Corp SC330 (330.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSolarCity Corp SC3: 330.0 W

What Dataset Percentiles Define SolarCity Corp SC330?

Benchmarks SolarCity Corp SC330 on STC wattage, thermal PTC/STC retention, and 19.71 aperture conversion efficiency against CEC peers.

SolarCity Corp SC330 Engineering BenchmarksPercentile comparison of SolarCity Corp SC330 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage330.0 WPTC/STC Retention94.3%Module Efficiency19.71%

What Do the Dataset Ranks Show for SolarCity Corp SC330?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for SolarCity Corp SC330 by SolarCity Corp.

Rank #14,165 / 21,677

330.0 W STC · Higher Than 32.9%

330.0 W STC (-55.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #11,491

19.71% Aperture Efficiency

Power density 197.1 W/m2 (0.20 percentage points below 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).

NEC 690.7 Limit

7 Panels Max @ -10 C (600 V)

Cold Voc reaches 75.8 V at -10 C (530.6 V string) and 77.54 V at -20 C (7 max).

8 kW Reference Array

25 Panels = 8,250 W STC

Occupies 41.9 m2 (450 sq ft) producing 7,782 W PTC; NEC 690.8 OCPD floor is 9.47 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 69.7 * (1 + (-0.25/100) * (-10 - 25)) = 75.8 V | OCPD = 1.56 * 6.07 = 9.47 A

Inputs from CEC Modules.csv for SolarCity Corp SC330: Voc=69.7 V, beta_Voc=-0.25%/C, Isc=6.07 A, STC=330.0 W, Area=1.674 m2.

Result: 7 panels max on 600 V (530.6 V); 25 panels for 8 kW (450 sq ft).

What Are the Published CEC Specifications for SolarCity Corp SC330?

Laboratory test ratings recorded for SolarCity Corp SC330 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for SolarCity Corp SC330.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 330.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 311.3 W (94.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 69.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 6.07 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 58.0 V / 5.7 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.25 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.71% (1.674 m2) Array roof footprint density
Cell Count & Technology 96 cells (Multi-c-Si) Monofacial backsheet

How Many SolarCity Corp SC330 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (450 sq ft at 8 kW), and estimated Year-1 electric bill offset for SolarCity Corp SC330.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.27 kW 342 sq ft $1,569 $2,654
8 kW Class 25 8.25 kW 450 sq ft $2,065 $3,492
10 kW Class 31 10.23 kW 559 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This SolarCity Corp Series?

Sibling wattage bins and frame colors grouped with SolarCity Corp SC330 under SolarCity Corp to prevent duplicate spec pages.

Sibling CEC listings grouped into the SolarCity Corp SC330 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SolarCity Corp SC325 325.0 W 306.5 W 69.6 V 57.6 V 19.41%
SolarCity Corp SC330 330.0 W 311.3 W 69.7 V 58.0 V 19.71%

How Many SolarCity Corp SC330 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for SolarCity Corp SC330 (beta_Voc -0.25%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=69.7V and beta_Voc=-0.25%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 77.54 V 7 panels 542.8 V 12 panels
-10 C (14 F) 75.8 V 7 panels 530.6 V 13 panels
0 C (32 F) 74.06 V 8 panels 592.5 V 13 panels
25 C (77 F STC) 69.7 V 8 panels 557.6 V 14 panels

Which Cross-Brand Solar Modules Compare Closest to SolarCity Corp SC330?

Closest cross-brand CEC competitors to SolarCity Corp SC330 matched near 330.0 W STC and 69.7 V Voc, led by Centrosolar America DM72 330.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DM72 330
Centrosolar America
330.0 W Tie (0 W) 46.9 V 16.97% 90.9%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
330.0 W Tie (0 W) 46.65 V 17.16% 91.3%
Centrosolar America EP72 330BW
Centrosolar America
330.0 W Tie (0 W) 46.65 V 17.16% 91.3%
Centrosolar America EP72 330SW
Centrosolar America
330.0 W Tie (0 W) 46.65 V 17.16% 91.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SolarCity Corp SC330?

Evaluate SolarCity Corp SC330 (330.0 W STC, 69.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SolarCity Corp SC330 reaches 77.54 V per panel—exceeding 7 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 450 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (450 sq ft).
  • 2026 tax credit baseline: cash residential installs of SolarCity Corp SC330 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SolarCity Corp SC330 8 kW Residential Fit

Needs 25 modules (450 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 7 panels (-10 C) or 7 panels (-20 C), or compare Centrosolar America DM72 330.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 311.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SolarCity Corp SC330 by SolarCity Corp grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for SolarCity Corp SC330?

Multiplying SolarCity Corp SC330's 6.07 A short-circuit current by 1.56 equals 9.47 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can SolarCity Corp SC330 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 75.8 V cold Voc at 14 F and handles 6.07 A Isc; string inverters cap SolarCity Corp SC330 at 7 panels on 600 V.

Is SolarCity Corp SC330 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SolarCity Corp SC330 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.