SolarCity Corp SC320 is a 320.0 W STC (301.7 W PTC) Multi-c-Si solar module ranking #14,944 of 21,677 CEC listings (below all-CEC median; higher than 29.0% of peers). It delivers 19.11% efficiency, 69.4 V Voc at 25 C, and 75.47 V cold Voc at -10 C (7 panels max per 600 V string).
- STC Wattage
- 320.0 W
- PTC Wattage
- 301.7 W
- Voc @ 25C
- 69.4 V
- Efficiency
- 19.11%
How Does SolarCity Corp SC320 Compare Against Peer CEC Listings?
Solar engineering breakdown for SolarCity Corp SC320: PTC thermal retention, roof footprint, and cold Voc string bounds. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
Measured at 320.0 W STC and 301.7 W PTC, SolarCity Corp SC320 sits -65.0 W vs all-CEC median (below all-CEC median; higher than 29.0% of peers) among 21,677 listed modules. Power density reaches 191.2 W/m2 (0.80 percentage points below 19.91% CEC median). Higher 69.4 V open-circuit voltage caps 600 V residential strings at 7 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 13 panels in series. Alternative peer Centrosolar America EM72 320BW rates 320.0 W.
Where Does SolarCity Corp SC320 Fall Across Listed CEC Models?
Distribution marker showing SolarCity Corp SC320 (320.0 W) relative to the 385.0 W all-CEC solar panel median. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Dataset Percentiles Define SolarCity Corp SC320?
Dataset percentiles tracking SolarCity Corp SC320 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
What Do the Dataset Ranks Show for SolarCity Corp SC320?
Benchmark highlights for SolarCity Corp SC320 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
320.0 W STC · Higher Than 29.0%
320.0 W STC (-65.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
19.11% Aperture Efficiency
Power density 191.2 W/m2 (0.80 percentage points below 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).
7 Panels Max @ -10 C (600 V)
Cold Voc reaches 75.47 V at -10 C (528.3 V string) and 77.21 V at -20 C (7 max).
25 Panels = 8,000 W STC
Occupies 41.9 m2 (450 sq ft) producing 7,542 W PTC; NEC 690.8 OCPD floor is 9.33 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 69.4 * (1 + (-0.25/100) * (-10 - 25)) = 75.47 V | OCPD = 1.56 * 5.98 = 9.33 A
Inputs from CEC Modules.csv for SolarCity Corp SC320: Voc=69.4 V, beta_Voc=-0.25%/C, Isc=5.98 A, STC=320.0 W, Area=1.674 m2.
Result: 7 panels max on 600 V (528.3 V); 25 panels for 8 kW (450 sq ft).
What Are the Published CEC Specifications for SolarCity Corp SC320?
Official CEC datasheet figures for SolarCity Corp SC320 (Multi-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 320.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 301.7 W (94.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 69.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 5.98 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 57.3 V / 5.59 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.25 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.11% (1.674 m2) | Array roof footprint density |
| Cell Count & Technology | 96 cells (Multi-c-Si) | Monofacial backsheet |
How Many SolarCity Corp SC320 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many SolarCity Corp SC320 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 19 | 6.08 kW | 342 sq ft | $1,522 | $2,573 |
| 8 kW Class | 25 | 8.0 kW | 450 sq ft | $2,002 | $3,386 |
| 10 kW Class | 32 | 10.24 kW | 577 sq ft | $2,563 | $4,334 |
How Many SolarCity Corp SC320 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on SolarCity Corp SC320 (75.47 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 77.21 V | 7 panels | 540.5 V | 12 panels |
| -10 C (14 F) | 75.47 V | 7 panels | 528.3 V | 13 panels |
| 0 C (32 F) | 73.74 V | 8 panels | 589.9 V | 13 panels |
| 25 C (77 F STC) | 69.4 V | 8 panels | 555.2 V | 14 panels |
Which Cross-Brand Solar Modules Compare Closest to SolarCity Corp SC320?
Competing CEC solar panels closest to SolarCity Corp SC320 in nameplate wattage and Voc, starting with Centrosolar America EM72 320BW.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America EM72 320BW Centrosolar America |
320.0 W | Tie (0 W) | 46.31 V | 16.64% | 91.3% |
| Centrosolar America EM72 320SW Centrosolar America |
320.0 W | Tie (0 W) | 46.31 V | 16.64% | 91.3% |
| Bluesun Solar Energy Tech CoLtd BSM320P-72 Bluesun Solar Energy Tech CoLtd |
320.0 W | Tie (0 W) | 46.19 V | 16.51% | 91.3% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-320W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
320.0 W | Tie (0 W) | 45.94 V | 16.64% | 91.2% |
What Are the Design Limits and Best-Fit Uses for SolarCity Corp SC320?
Evaluate SolarCity Corp SC320 (320.0 W STC, 69.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), SolarCity Corp SC320 reaches 77.21 V per panel—exceeding 7 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 450 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (450 sq ft).
- 2026 tax credit baseline: cash residential installs of SolarCity Corp SC320 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
SolarCity Corp SC320 8 kW Residential Fit
Needs 25 modules (450 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 7 panels (-10 C) or 7 panels (-20 C), or compare Centrosolar America EM72 320BW.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 301.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for SolarCity Corp SC320 by SolarCity Corp grounded in CEC test data and NEC 690.7/690.8 limits.
How many SolarCity Corp SC320 panels fit on a 600 V winter solar string?
At -10 C (14 F), SolarCity Corp SC320 cold Voc rises from 69.4 V to 75.47 V (beta_Voc -0.25%/C), capping a 600 V string at 7 panels (528.3 V).
How much roof area does an 8 kW array of SolarCity Corp SC320 need?
An 8 kW DC system uses 25 SolarCity Corp SC320 modules (8,000 W STC / 7,542 W PTC), covering roughly 450 sq ft and saving ~$2,002/yr at 18.54 c/kWh.
How does SolarCity Corp SC320 compare against Centrosolar America EM72 320BW?
SolarCity Corp SC320 outputs 320.0 W STC (69.4 V Voc, rank #14,944 of 21,677), while Centrosolar America EM72 320BW delivers 320.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)