Skip to main content
WireAndSun
Calculators
CEC PV Module

Shanghai ST Solar STM195-72 — CEC Solar Module Specifications

Manufacturer: Shanghai ST Solar Registry: CEC Verified Engineering Specification

Shanghai ST Solar STM195-72 is a 195.0 W STC (174.3 W PTC) Mono-c-Si solar module ranking #21,088 of 21,677 CEC listings (below all-CEC median; higher than 2.5% of peers). It delivers 15.27% efficiency, 45.0 V Voc at 25 C, and 50.35 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
195.0 W
PTC Wattage
174.3 W
Voc @ 25C
45.0 V
Efficiency
15.27%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Shanghai ST Solar STM195-72 Compare Against Peer CEC Listings?

Solar engineering breakdown for Shanghai ST Solar STM195-72: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 195.0 W STC and 174.3 W PTC, Shanghai ST Solar STM195-72 sits -190.0 W vs all-CEC median (below all-CEC median; higher than 2.5% of peers) among 21,677 listed modules. Power density reaches 152.7 W/m2 (4.64 percentage points below 19.91% CEC median). Mid-range 45.0 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 19 panels in series. Alternative peer Phono Solar Technology Co Ltd PS190M-24/F rates 190.0 W.

Where Does Shanghai ST Solar STM195-72 Fall Across Listed CEC Models?

Distribution marker showing Shanghai ST Solar STM195-72 (195.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Shanghai ST Solar STM195-72 (195.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCShanghai ST Solar : 195.0 W

What Dataset Percentiles Define Shanghai ST Solar STM195-72?

Dataset percentiles tracking Shanghai ST Solar STM195-72 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Shanghai ST Solar STM195-72 Engineering BenchmarksPercentile comparison of Shanghai ST Solar STM195-72 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage195.0 WPTC/STC Retention89.4%Module Efficiency15.27%

What Do the Dataset Ranks Show for Shanghai ST Solar STM195-72?

Benchmark highlights for Shanghai ST Solar STM195-72 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #21,088 / 21,677

195.0 W STC · Higher Than 2.5%

195.0 W STC (-190.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,289

15.27% Aperture Efficiency

Power density 152.7 W/m2 (4.64 percentage points below 19.91% CEC median). PTC/STC ratio: 89.4% (rank #20,078).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.35 V at -10 C (553.9 V string) and 51.88 V at -20 C (11 max).

8 kW Reference Array

42 Panels = 8,190 W STC

Occupies 53.6 m2 (577 sq ft) producing 7,321 W PTC; NEC 690.8 OCPD floor is 9.39 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.0 * (1 + (-0.34/100) * (-10 - 25)) = 50.35 V | OCPD = 1.56 * 6.02 = 9.39 A

Inputs from CEC Modules.csv for Shanghai ST Solar STM195-72: Voc=45.0 V, beta_Voc=-0.34%/C, Isc=6.02 A, STC=195.0 W, Area=1.277 m2.

Result: 11 panels max on 600 V (553.9 V); 42 panels for 8 kW (577 sq ft).

What Are the Published CEC Specifications for Shanghai ST Solar STM195-72?

Official CEC datasheet figures for Shanghai ST Solar STM195-72 (Mono-c-Si) used in utility interconnection and permit reviews. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for Shanghai ST Solar STM195-72.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 195.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 174.3 W (89.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 6.02 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.0 V / 5.42 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.34 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.27% (1.277 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Shanghai ST Solar STM195-72 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Shanghai ST Solar STM195-72 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 31 6.04 kW 426 sq ft $1,512 $2,556
8 kW Class 42 8.19 kW 577 sq ft $2,050 $3,466
10 kW Class 52 10.14 kW 715 sq ft $2,538 $4,292

How Many Shanghai ST Solar STM195-72 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Shanghai ST Solar STM195-72 (50.35 V at 14 F).

Computed from Voc=45.0V and beta_Voc=-0.34%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.88 V 11 panels 570.7 V 19 panels
-10 C (14 F) 50.35 V 11 panels 553.9 V 19 panels
0 C (32 F) 48.82 V 12 panels 585.8 V 20 panels
25 C (77 F STC) 45.0 V 13 panels 585.0 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Shanghai ST Solar STM195-72?

Competing CEC solar panels closest to Shanghai ST Solar STM195-72 in nameplate wattage and Voc, starting with Phono Solar Technology Co Ltd PS190M-24/F.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Phono Solar Technology Co Ltd PS190M-24/F
Phono Solar Technology Co Ltd
190.0 W -5.0 W 45.0 V 14.88% 91.1%
Seraphim Solar System CoLtd SRP-190-5MB
Seraphim Solar System CoLtd
190.0 W -5.0 W 45.1 V 14.88% 90.3%
Trina Solar TSM-190DA01A
Trina Solar
190.0 W -5.0 W 45.1 V 15.05% 90.2%
Trina Solar TSM-190DA01A05
Trina Solar
190.0 W -5.0 W 45.1 V 15.05% 90.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Shanghai ST Solar STM195-72?

Evaluate Shanghai ST Solar STM195-72 (195.0 W STC, 45.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Shanghai ST Solar STM195-72 reaches 51.88 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 42 panels for an 8 kW build require 577 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 42 panels (577 sq ft).
  • 2026 tax credit baseline: cash residential installs of Shanghai ST Solar STM195-72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Shanghai ST Solar STM195-72 8 kW Residential Fit

Needs 42 modules (577 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Phono Solar Technology Co Ltd PS190M-24/F.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 174.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Shanghai ST Solar STM195-72 by Shanghai ST Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Shanghai ST Solar STM195-72 panels fit on a 600 V winter solar string?

At -10 C (14 F), Shanghai ST Solar STM195-72 cold Voc rises from 45.0 V to 50.35 V (beta_Voc -0.34%/C), capping a 600 V string at 11 panels (553.9 V).

How much roof area does an 8 kW array of Shanghai ST Solar STM195-72 need?

An 8 kW DC system uses 42 Shanghai ST Solar STM195-72 modules (8,190 W STC / 7,321 W PTC), covering roughly 577 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

How does Shanghai ST Solar STM195-72 compare against Phono Solar Technology Co Ltd PS190M-24/F?

Shanghai ST Solar STM195-72 outputs 195.0 W STC (45.0 V Voc, rank #21,088 of 21,677), while Phono Solar Technology Co Ltd PS190M-24/F delivers 190.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.