Skip to main content
WireAndSun
Calculators
CEC PV Module

Seraphim Solar System CoLtd SRP-235-6PC — CEC Solar Module Specifications

Manufacturer: Seraphim Solar System CoLtd Registry: CEC Verified Engineering Specification

Seraphim Solar System CoLtd SRP-235-6PC is a 235.0 W STC (211.9 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 15.99% efficiency, 33.6 V Voc at 25 C, and 37.32 V cold Voc at -10 C (16 panels max per 600 V string).

STC Wattage
235.0 W
PTC Wattage
211.9 W
Voc @ 25C
33.6 V
Efficiency
15.99%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Seraphim Solar System CoLtd SRP-235-6PC Compare Against Peer CEC Listings?

Solar engineering breakdown for Seraphim Solar System CoLtd SRP-235-6PC: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 235.0 W STC and 211.9 W PTC, Seraphim Solar System CoLtd SRP-235-6PC sits -150.0 W vs all-CEC median (below all-CEC median; higher than 5.4% of peers) among 21,677 listed modules. Power density reaches 159.9 W/m2 (3.92 percentage points below 19.91% CEC median). Lower 33.6 V string voltage fits 16 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 26 panels in series. Alternative peer Gintung Energy ASEC-235G6M69 rates 235.0 W.

Where Does Seraphim Solar System CoLtd SRP-235-6PC Fall Across Listed CEC Models?

Distribution marker showing Seraphim Solar System CoLtd SRP-235-6PC (235.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Seraphim Solar System CoLtd SRP-235-6PC (235.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSeraphim Solar Sys: 235.0 W

What Dataset Percentiles Define Seraphim Solar System CoLtd SRP-235-6PC?

Dataset percentiles tracking Seraphim Solar System CoLtd SRP-235-6PC power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Seraphim Solar System CoLtd SRP-235-6PC Engineering BenchmarksPercentile comparison of Seraphim Solar System CoLtd SRP-235-6PC wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage235.0 WPTC/STC Retention90.2%Module Efficiency15.99%

What Do the Dataset Ranks Show for Seraphim Solar System CoLtd SRP-235-6PC?

Benchmark highlights for Seraphim Solar System CoLtd SRP-235-6PC covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #20,368 / 21,677

235.0 W STC · Higher Than 5.4%

235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,133

15.99% Aperture Efficiency

Power density 159.9 W/m2 (3.92 percentage points below 19.91% CEC median). PTC/STC ratio: 90.2% (rank #18,532).

NEC 690.7 Limit

16 Panels Max @ -10 C (600 V)

Cold Voc reaches 37.32 V at -10 C (597.1 V string) and 38.38 V at -20 C (15 max).

8 kW Reference Array

35 Panels = 8,225 W STC

Occupies 51.4 m2 (554 sq ft) producing 7,416 W PTC; NEC 690.8 OCPD floor is 14.35 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 33.6 * (1 + (-0.316/100) * (-10 - 25)) = 37.32 V | OCPD = 1.56 * 9.2 = 14.35 A

Inputs from CEC Modules.csv for Seraphim Solar System CoLtd SRP-235-6PC: Voc=33.6 V, beta_Voc=-0.316%/C, Isc=9.2 A, STC=235.0 W, Area=1.47 m2.

Result: 16 panels max on 600 V (597.1 V); 35 panels for 8 kW (554 sq ft).

What Are the Published CEC Specifications for Seraphim Solar System CoLtd SRP-235-6PC?

Official CEC datasheet figures for Seraphim Solar System CoLtd SRP-235-6PC (Multi-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Seraphim Solar System CoLtd SRP-235-6PC.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 235.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 211.9 W (90.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 33.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.2 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 27.3 V / 8.62 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.316 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.99% (1.47 m2) Array roof footprint density
Cell Count & Technology 54 cells (Multi-c-Si) Monofacial backsheet

How Many Seraphim Solar System CoLtd SRP-235-6PC Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Seraphim Solar System CoLtd SRP-235-6PC modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 26 6.11 kW 411 sq ft $1,529 $2,586
8 kW Class 35 8.22 kW 554 sq ft $2,057 $3,479
10 kW Class 43 10.11 kW 680 sq ft $2,530 $4,279

Which Sibling Wattage & Trim Variants Belong to This Seraphim Solar System CoLtd Series?

Consolidated Seraphim Solar System CoLtd wattage variants sharing the Seraphim Solar System CoLtd SRP-235-6PC mechanical and cell layout.

Sibling CEC listings grouped into the Seraphim Solar System CoLtd SRP-235-6PC wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Seraphim Solar System CoLtd SRP-225-6PC 225.0 W 202.7 W 33.4 V 27.2 V 15.31%
Seraphim Solar System CoLtd SRP-230-6PC 230.0 W 207.3 W 33.5 V 27.2 V 15.65%
Seraphim Solar System CoLtd SRP-235-6PC 235.0 W 211.9 W 33.6 V 27.3 V 15.99%
Seraphim Solar System CoLtd SRP-240-6PC 240.0 W 216.6 W 33.7 V 27.4 V 16.33%

How Many Seraphim Solar System CoLtd SRP-235-6PC Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Seraphim Solar System CoLtd SRP-235-6PC (37.32 V at 14 F).

Computed from Voc=33.6V and beta_Voc=-0.316%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 38.38 V 15 panels 575.7 V 26 panels
-10 C (14 F) 37.32 V 16 panels 597.1 V 26 panels
0 C (32 F) 36.25 V 16 panels 580.0 V 27 panels
25 C (77 F STC) 33.6 V 17 panels 571.2 V 29 panels

Which Cross-Brand Solar Modules Compare Closest to Seraphim Solar System CoLtd SRP-235-6PC?

Competing CEC solar panels closest to Seraphim Solar System CoLtd SRP-235-6PC in nameplate wattage and Voc, starting with Gintung Energy ASEC-235G6M69.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Gintung Energy ASEC-235G6M69
Gintung Energy
235.0 W Tie (0 W) 34.06 V 16.04% 88.1%
Gintung Energy GTEC-235G6M69
Gintung Energy
235.0 W Tie (0 W) 34.06 V 16.04% 88.1%
Gintung Energy ASEC-235G6S69
Gintung Energy
235.0 W Tie (0 W) 34.13 V 16.04% 87.7%
Gintung Energy GTEC-235G6S69
Gintung Energy
235.0 W Tie (0 W) 34.13 V 16.04% 87.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Seraphim Solar System CoLtd SRP-235-6PC?

Evaluate Seraphim Solar System CoLtd SRP-235-6PC (235.0 W STC, 33.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Seraphim Solar System CoLtd SRP-235-6PC reaches 38.38 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 35 panels for an 8 kW build require 554 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (554 sq ft).
  • 2026 tax credit baseline: cash residential installs of Seraphim Solar System CoLtd SRP-235-6PC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Seraphim Solar System CoLtd SRP-235-6PC 8 kW Residential Fit

Needs 35 modules (554 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 16 panels (-10 C) or 15 panels (-20 C), or compare Gintung Energy ASEC-235G6M69.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 211.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Seraphim Solar System CoLtd SRP-235-6PC by Seraphim Solar System CoLtd grounded in CEC test data and NEC 690.7/690.8 limits.

How many Seraphim Solar System CoLtd SRP-235-6PC panels fit on a 600 V winter solar string?

At -10 C (14 F), Seraphim Solar System CoLtd SRP-235-6PC cold Voc rises from 33.6 V to 37.32 V (beta_Voc -0.316%/C), capping a 600 V string at 16 panels (597.1 V).

How much roof area does an 8 kW array of Seraphim Solar System CoLtd SRP-235-6PC need?

An 8 kW DC system uses 35 Seraphim Solar System CoLtd SRP-235-6PC modules (8,225 W STC / 7,416 W PTC), covering roughly 554 sq ft and saving ~$2,057/yr at 18.54 c/kWh.

How does Seraphim Solar System CoLtd SRP-235-6PC compare against Gintung Energy ASEC-235G6M69?

Seraphim Solar System CoLtd SRP-235-6PC outputs 235.0 W STC (33.6 V Voc, rank #20,368 of 21,677), while Gintung Energy ASEC-235G6M69 delivers 235.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.