Seraphim Solar System CoLtd SRP-235-6PC is a 235.0 W STC (211.9 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 15.99% efficiency, 33.6 V Voc at 25 C, and 37.32 V cold Voc at -10 C (16 panels max per 600 V string).
- STC Wattage
- 235.0 W
- PTC Wattage
- 211.9 W
- Voc @ 25C
- 33.6 V
- Efficiency
- 15.99%
How Does Seraphim Solar System CoLtd SRP-235-6PC Compare Against Peer CEC Listings?
Solar engineering breakdown for Seraphim Solar System CoLtd SRP-235-6PC: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 235.0 W STC and 211.9 W PTC, Seraphim Solar System CoLtd SRP-235-6PC sits -150.0 W vs all-CEC median (below all-CEC median; higher than 5.4% of peers) among 21,677 listed modules. Power density reaches 159.9 W/m2 (3.92 percentage points below 19.91% CEC median). Lower 33.6 V string voltage fits 16 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 26 panels in series. Alternative peer Gintung Energy ASEC-235G6M69 rates 235.0 W.
Where Does Seraphim Solar System CoLtd SRP-235-6PC Fall Across Listed CEC Models?
Distribution marker showing Seraphim Solar System CoLtd SRP-235-6PC (235.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Seraphim Solar System CoLtd SRP-235-6PC?
Dataset percentiles tracking Seraphim Solar System CoLtd SRP-235-6PC power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Seraphim Solar System CoLtd SRP-235-6PC?
Benchmark highlights for Seraphim Solar System CoLtd SRP-235-6PC covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
235.0 W STC · Higher Than 5.4%
235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.99% Aperture Efficiency
Power density 159.9 W/m2 (3.92 percentage points below 19.91% CEC median). PTC/STC ratio: 90.2% (rank #18,532).
16 Panels Max @ -10 C (600 V)
Cold Voc reaches 37.32 V at -10 C (597.1 V string) and 38.38 V at -20 C (15 max).
35 Panels = 8,225 W STC
Occupies 51.4 m2 (554 sq ft) producing 7,416 W PTC; NEC 690.8 OCPD floor is 14.35 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 33.6 * (1 + (-0.316/100) * (-10 - 25)) = 37.32 V | OCPD = 1.56 * 9.2 = 14.35 A
Inputs from CEC Modules.csv for Seraphim Solar System CoLtd SRP-235-6PC: Voc=33.6 V, beta_Voc=-0.316%/C, Isc=9.2 A, STC=235.0 W, Area=1.47 m2.
Result: 16 panels max on 600 V (597.1 V); 35 panels for 8 kW (554 sq ft).
What Are the Published CEC Specifications for Seraphim Solar System CoLtd SRP-235-6PC?
Official CEC datasheet figures for Seraphim Solar System CoLtd SRP-235-6PC (Multi-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 235.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 211.9 W (90.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 33.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 27.3 V / 8.62 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.316 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.99% (1.47 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Multi-c-Si) | Monofacial backsheet |
How Many Seraphim Solar System CoLtd SRP-235-6PC Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Seraphim Solar System CoLtd SRP-235-6PC modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 26 | 6.11 kW | 411 sq ft | $1,529 | $2,586 |
| 8 kW Class | 35 | 8.22 kW | 554 sq ft | $2,057 | $3,479 |
| 10 kW Class | 43 | 10.11 kW | 680 sq ft | $2,530 | $4,279 |
Which Sibling Wattage & Trim Variants Belong to This Seraphim Solar System CoLtd Series?
Consolidated Seraphim Solar System CoLtd wattage variants sharing the Seraphim Solar System CoLtd SRP-235-6PC mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Seraphim Solar System CoLtd SRP-225-6PC | 225.0 W | 202.7 W | 33.4 V | 27.2 V | 15.31% |
| Seraphim Solar System CoLtd SRP-230-6PC | 230.0 W | 207.3 W | 33.5 V | 27.2 V | 15.65% |
| Seraphim Solar System CoLtd SRP-235-6PC | 235.0 W | 211.9 W | 33.6 V | 27.3 V | 15.99% |
| Seraphim Solar System CoLtd SRP-240-6PC | 240.0 W | 216.6 W | 33.7 V | 27.4 V | 16.33% |
How Many Seraphim Solar System CoLtd SRP-235-6PC Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Seraphim Solar System CoLtd SRP-235-6PC (37.32 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 38.38 V | 15 panels | 575.7 V | 26 panels |
| -10 C (14 F) | 37.32 V | 16 panels | 597.1 V | 26 panels |
| 0 C (32 F) | 36.25 V | 16 panels | 580.0 V | 27 panels |
| 25 C (77 F STC) | 33.6 V | 17 panels | 571.2 V | 29 panels |
Which Cross-Brand Solar Modules Compare Closest to Seraphim Solar System CoLtd SRP-235-6PC?
Competing CEC solar panels closest to Seraphim Solar System CoLtd SRP-235-6PC in nameplate wattage and Voc, starting with Gintung Energy ASEC-235G6M69.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Gintung Energy ASEC-235G6M69 Gintung Energy |
235.0 W | Tie (0 W) | 34.06 V | 16.04% | 88.1% |
| Gintung Energy GTEC-235G6M69 Gintung Energy |
235.0 W | Tie (0 W) | 34.06 V | 16.04% | 88.1% |
| Gintung Energy ASEC-235G6S69 Gintung Energy |
235.0 W | Tie (0 W) | 34.13 V | 16.04% | 87.7% |
| Gintung Energy GTEC-235G6S69 Gintung Energy |
235.0 W | Tie (0 W) | 34.13 V | 16.04% | 87.7% |
What Are the Design Limits and Best-Fit Uses for Seraphim Solar System CoLtd SRP-235-6PC?
Evaluate Seraphim Solar System CoLtd SRP-235-6PC (235.0 W STC, 33.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Seraphim Solar System CoLtd SRP-235-6PC reaches 38.38 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
- Footprint constraint: 35 panels for an 8 kW build require 554 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (554 sq ft).
- 2026 tax credit baseline: cash residential installs of Seraphim Solar System CoLtd SRP-235-6PC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Seraphim Solar System CoLtd SRP-235-6PC 8 kW Residential Fit
Needs 35 modules (554 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 16 panels (-10 C) or 15 panels (-20 C), or compare Gintung Energy ASEC-235G6M69.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 211.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Seraphim Solar System CoLtd SRP-235-6PC by Seraphim Solar System CoLtd grounded in CEC test data and NEC 690.7/690.8 limits.
How many Seraphim Solar System CoLtd SRP-235-6PC panels fit on a 600 V winter solar string?
At -10 C (14 F), Seraphim Solar System CoLtd SRP-235-6PC cold Voc rises from 33.6 V to 37.32 V (beta_Voc -0.316%/C), capping a 600 V string at 16 panels (597.1 V).
How much roof area does an 8 kW array of Seraphim Solar System CoLtd SRP-235-6PC need?
An 8 kW DC system uses 35 Seraphim Solar System CoLtd SRP-235-6PC modules (8,225 W STC / 7,416 W PTC), covering roughly 554 sq ft and saving ~$2,057/yr at 18.54 c/kWh.
How does Seraphim Solar System CoLtd SRP-235-6PC compare against Gintung Energy ASEC-235G6M69?
Seraphim Solar System CoLtd SRP-235-6PC outputs 235.0 W STC (33.6 V Voc, rank #20,368 of 21,677), while Gintung Energy ASEC-235G6M69 delivers 235.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)