Seraphim Solar System CoLtd SRP-610-BTA-BG is a 610.0 W STC (574.6 W PTC) Mono-c-Si solar module ranking #1,104 of 21,677 CEC listings (top 5.6%; higher than 94.4% of peers). It delivers 23.83% efficiency, 53.3 V Voc at 25 C, and 58.32 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 610.0 W
- PTC Wattage
- 574.6 W
- Voc @ 25C
- 53.3 V
- Efficiency
- 23.83%
How Does Seraphim Solar System CoLtd SRP-610-BTA-BG Compare Against Peer CEC Listings?
Engineering position of Seraphim Solar System CoLtd SRP-610-BTA-BG (610.0 W STC) vs. CSI Solar Co Ltd CS61-72TB-610H across 5,889 CEC Mono-c-Si solar modules.
Built with 72 Mono-c-Si cells, Seraphim Solar System CoLtd SRP-610-BTA-BG pairs strong 94.2% PTC-to-STC heat retention (#3,689 of 21,677) with 53.3 V nominal Voc. An 8 kW residential build (8,540 W DC, 8,044 W PTC) saves ~$2,137/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer CSI Solar Co Ltd CS61-72TB-610H offers a 610.0 W alternative.
Where Does Seraphim Solar System CoLtd SRP-610-BTA-BG Fall Across Listed CEC Models?
Plots Seraphim Solar System CoLtd SRP-610-BTA-BG at 610.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Seraphim Solar System CoLtd SRP-610-BTA-BG?
Benchmarks Seraphim Solar System CoLtd SRP-610-BTA-BG on STC wattage, thermal PTC/STC retention, and 23.83 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Seraphim Solar System CoLtd SRP-610-BTA-BG?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Seraphim Solar System CoLtd SRP-610-BTA-BG by Seraphim Solar System CoLtd.
Top 5.6% STC Output
610.0 W STC (+225.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.83% Aperture Efficiency
Power density 238.3 W/m2 (3.92 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 58.32 V at -10 C (583.2 V string) and 59.75 V at -20 C (10 max).
14 Panels = 8,540 W STC
Occupies 35.8 m2 (386 sq ft) producing 8,044 W PTC; NEC 690.8 OCPD floor is 22.51 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 53.3 * (1 + (-0.269/100) * (-10 - 25)) = 58.32 V | OCPD = 1.56 * 14.43 = 22.51 A
Inputs from CEC Modules.csv for Seraphim Solar System CoLtd SRP-610-BTA-BG: Voc=53.3 V, beta_Voc=-0.269%/C, Isc=14.43 A, STC=610.0 W, Area=2.56 m2.
Result: 10 panels max on 600 V (583.2 V); 14 panels for 8 kW (386 sq ft).
What Are the Published CEC Specifications for Seraphim Solar System CoLtd SRP-610-BTA-BG?
Laboratory test ratings recorded for Seraphim Solar System CoLtd SRP-610-BTA-BG (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 610.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 574.6 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 53.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.43 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 44.6 V / 13.68 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.269 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.83% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Seraphim Solar System CoLtd SRP-610-BTA-BG Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (386 sq ft at 8 kW), and estimated Year-1 electric bill offset for Seraphim Solar System CoLtd SRP-610-BTA-BG.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.1 kW | 276 sq ft | $1,527 | $2,582 |
| 8 kW Class | 14 | 8.54 kW | 386 sq ft | $2,137 | $3,614 |
| 10 kW Class | 17 | 10.37 kW | 468 sq ft | $2,596 | $4,389 |
Which Sibling Wattage & Trim Variants Belong to This Seraphim Solar System CoLtd Series?
Sibling wattage bins and frame colors grouped with Seraphim Solar System CoLtd SRP-610-BTA-BG under Seraphim Solar System CoLtd to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Seraphim Solar System CoLtd SRP-600-BTA-BG | 600.0 W | 565.0 W | 52.9 V | 44.2 V | 23.44% |
| Seraphim Solar System CoLtd SRP-605-BTA-BG | 605.0 W | 569.8 W | 53.1 V | 44.4 V | 23.63% |
| Seraphim Solar System CoLtd SRP-610-BTA-BG | 610.0 W | 574.6 W | 53.3 V | 44.6 V | 23.83% |
| Seraphim Solar System CoLtd SRP-615-BTA-BG | 615.0 W | 579.5 W | 53.5 V | 44.8 V | 24.02% |
How Many Seraphim Solar System CoLtd SRP-610-BTA-BG Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Seraphim Solar System CoLtd SRP-610-BTA-BG (beta_Voc -0.269%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 59.75 V | 10 panels | 597.5 V | 16 panels |
| -10 C (14 F) | 58.32 V | 10 panels | 583.2 V | 17 panels |
| 0 C (32 F) | 56.88 V | 10 panels | 568.8 V | 17 panels |
| 25 C (77 F STC) | 53.3 V | 11 panels | 586.3 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to Seraphim Solar System CoLtd SRP-610-BTA-BG?
Closest cross-brand CEC competitors to Seraphim Solar System CoLtd SRP-610-BTA-BG matched near 610.0 W STC and 53.3 V Voc, led by CSI Solar Co Ltd CS61-72TB-610H.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS61-72TB-610H CSI Solar Co Ltd |
610.0 W | Tie (0 W) | 52.2 V | 23.28% | 95.3% |
| Elin Energy (Sirius PV) ELNSM78M-HC-BF-610 Elin Energy (Sirius PV) |
610.0 W | Tie (0 W) | 54.63 V | 22.02% | 94.5% |
| Chint New Energy Technology Co Ltd CHSM72RN(DG)/F-BH-610 Chint New Energy Technology Co Ltd |
610.0 W | Tie (0 W) | 51.8 V | 22.59% | 94.7% |
| JA Solar JAM78D30-605/MB JA Solar |
605.0 W | -5.0 W | 53.61 V | 22.24% | 93.8% |
What Are the Design Limits and Best-Fit Uses for Seraphim Solar System CoLtd SRP-610-BTA-BG?
Evaluate Seraphim Solar System CoLtd SRP-610-BTA-BG (610.0 W STC, 53.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Seraphim Solar System CoLtd SRP-610-BTA-BG reaches 59.75 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 386 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Seraphim Solar System CoLtd SRP-610-BTA-BG carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Seraphim Solar System CoLtd SRP-610-BTA-BG 8 kW Residential Fit
Needs 14 modules (386 sq ft) with a 25 A string OCPD, offsetting ~$2,137/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS61-72TB-610H.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 574.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Seraphim Solar System CoLtd SRP-610-BTA-BG by Seraphim Solar System CoLtd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Seraphim Solar System CoLtd SRP-610-BTA-BG?
Multiplying Seraphim Solar System CoLtd SRP-610-BTA-BG's 14.43 A short-circuit current by 1.56 equals 22.51 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Seraphim Solar System CoLtd SRP-610-BTA-BG pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 58.32 V cold Voc at 14 F and handles 14.43 A Isc; string inverters cap Seraphim Solar System CoLtd SRP-610-BTA-BG at 10 panels on 600 V.
Is Seraphim Solar System CoLtd SRP-610-BTA-BG eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Seraphim Solar System CoLtd SRP-610-BTA-BG rely on utility bill offset (~$2,137/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)