S-Energy Co Ltd SN310P-10 is a 310.0 W STC (280.5 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.89% efficiency, 45.4 V Voc at 25 C, and 50.33 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 310.0 W
- PTC Wattage
- 280.5 W
- Voc @ 25C
- 45.4 V
- Efficiency
- 15.89%
How Does S-Energy Co Ltd SN310P-10 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for S-Energy Co Ltd SN310P-10 (Multi-c-Si) residential solar systems.
Homeowners evaluating S-Energy Co Ltd SN310P-10 need 20 panels for 6 kW or 26 panels (546 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (546 sq ft). Under NEC 690.7(A), beta_Voc (-0.31%/C) pushes open-circuit voltage to 50.33 V at 14 F and 51.73 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does S-Energy Co Ltd SN310P-10 Fall Across Listed CEC Models?
Comparison of S-Energy Co Ltd SN310P-10 (310.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define S-Energy Co Ltd SN310P-10?
Relative ranking of S-Energy Co Ltd SN310P-10 across nameplate watts, 90.5% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for S-Energy Co Ltd SN310P-10?
Summary of S-Energy Co Ltd SN310P-10 output rank, 8 kW array size (26 panels), efficiency rating, and 600 V string limit.
310.0 W STC · Higher Than 25.6%
310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.89% Aperture Efficiency
Power density 159.0 W/m2 (4.02 percentage points below 19.91% CEC median). PTC/STC ratio: 90.5% (rank #17,786).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.33 V at -10 C (553.6 V string) and 51.73 V at -20 C (11 max).
26 Panels = 8,060 W STC
Occupies 50.7 m2 (546 sq ft) producing 7,293 W PTC; NEC 690.8 OCPD floor is 13.98 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.4 * (1 + (-0.31/100) * (-10 - 25)) = 50.33 V | OCPD = 1.56 * 8.96 = 13.98 A
Inputs from CEC Modules.csv for S-Energy Co Ltd SN310P-10: Voc=45.4 V, beta_Voc=-0.31%/C, Isc=8.96 A, STC=310.0 W, Area=1.95 m2.
Result: 11 panels max on 600 V (553.6 V); 26 panels for 8 kW (546 sq ft).
What Are the Published CEC Specifications for S-Energy Co Ltd SN310P-10?
Complete CEC test sheet for S-Energy Co Ltd SN310P-10 including Isc (8.96 A), Voc (45.4 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 280.5 W (90.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.96 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.3 V / 8.54 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.31 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.89% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many S-Energy Co Ltd SN310P-10 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using S-Energy Co Ltd SN310P-10.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.2 kW | 420 sq ft | $1,552 | $2,624 |
| 8 kW Class | 26 | 8.06 kW | 546 sq ft | $2,017 | $3,411 |
| 10 kW Class | 33 | 10.23 kW | 693 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This S-Energy Co Ltd Series?
Related S-Energy Co Ltd power steps and black/silver trims consolidated into this S-Energy Co Ltd SN310P-10 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| S-Energy Co Ltd SN300P-10 | 300.0 W | 271.2 W | 44.9 V | 35.5 V | 15.38% |
| S-Energy Co Ltd SN305P-10 | 305.0 W | 275.8 W | 45.1 V | 36.0 V | 15.64% |
| S-Energy Co Ltd SN310P-10 | 310.0 W | 280.5 W | 45.4 V | 36.3 V | 15.89% |
| S-Energy Co Ltd SN315P-10 | 315.0 W | 285.1 W | 45.8 V | 36.6 V | 16.15% |
| S-Energy Co Ltd SN320P-10 | 320.0 W | 291.0 W | 45.9 V | 36.9 V | 16.41% |
How Many S-Energy Co Ltd SN310P-10 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for S-Energy Co Ltd SN310P-10 (45.4 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.73 V | 11 panels | 569.0 V | 19 panels |
| -10 C (14 F) | 50.33 V | 11 panels | 553.6 V | 19 panels |
| 0 C (32 F) | 48.92 V | 12 panels | 587.0 V | 20 panels |
| 25 C (77 F STC) | 45.4 V | 13 panels | 590.2 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to S-Energy Co Ltd SN310P-10?
Four comparable CEC modules such as Chinaland Solar Energy HSE310-72M (310.0 W) for side-by-side solar quote checks. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Chinaland Solar Energy HSE310-72M Chinaland Solar Energy |
310.0 W | Tie (0 W) | 45.4 V | 16.06% | 90.3% |
| GCL System Integration Technology Co Ltd GCL-P6/72310 GCL System Integration Technology Co Ltd |
310.0 W | Tie (0 W) | 45.4 V | 15.98% | 90.5% |
| AXITEC AC-310M/156-72S AXITEC |
310.0 W | Tie (0 W) | 45.49 V | 16.01% | 90.2% |
| Advance Power API-P310 Advance Power |
310.0 W | Tie (0 W) | 45.22 V | 15.89% | 89.5% |
What Are the Design Limits and Best-Fit Uses for S-Energy Co Ltd SN310P-10?
Evaluate S-Energy Co Ltd SN310P-10 (310.0 W STC, 45.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), S-Energy Co Ltd SN310P-10 reaches 51.73 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 546 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (546 sq ft).
- 2026 tax credit baseline: cash residential installs of S-Energy Co Ltd SN310P-10 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
S-Energy Co Ltd SN310P-10 8 kW Residential Fit
Needs 26 modules (546 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Chinaland Solar Energy HSE310-72M.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 280.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for S-Energy Co Ltd SN310P-10 by S-Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is S-Energy Co Ltd SN310P-10 PTC wattage (280.5 W) lower than STC (310.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 280.5 W PTC (90.5% retention) across S-Energy Co Ltd SN310P-10's 1.95 m2 aperture.
Who should skip S-Energy Co Ltd SN310P-10 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 26 S-Energy Co Ltd SN310P-10 panels (546 sq ft) leave unusable roof gaps vs. Chinaland Solar Energy HSE310-72M.
What is the 1,000 V commercial string limit for S-Energy Co Ltd SN310P-10?
On 1,000 V commercial inverters at -10 C (50.33 V cold Voc), S-Energy Co Ltd SN310P-10 fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting S-Energy Co Ltd SN310P-10.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)