Skip to main content
WireAndSun
Calculators
CEC PV Module

S-Energy Co Ltd SL45-72MCI-460V — CEC Solar Module Specifications

Manufacturer: S-Energy Co Ltd Registry: CEC Verified Engineering Specification

S-Energy Co Ltd SL45-72MCI-460V is a 460.0 W STC (427.5 W PTC) Mono-c-Si solar module ranking #5,199 of 21,677 CEC listings (top 25.0%; higher than 75.0% of peers). It delivers 21.0% efficiency, 50.4 V Voc at 25 C, and 55.66 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
460.0 W
PTC Wattage
427.5 W
Voc @ 25C
50.4 V
Efficiency
21.0%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does S-Energy Co Ltd SL45-72MCI-460V Compare Against Peer CEC Listings?

Solar engineering breakdown for S-Energy Co Ltd SL45-72MCI-460V: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 460.0 W STC and 427.5 W PTC, S-Energy Co Ltd SL45-72MCI-460V sits +75.0 W vs all-CEC median (top 25.0%; higher than 75.0% of peers) among 21,677 listed modules. Power density reaches 210.0 W/m2 (1.09 percentage points above 19.91% CEC median). Higher 50.4 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 17 panels in series. Alternative peer Heliene 144HC-460 rates 460.0 W.

Where Does S-Energy Co Ltd SL45-72MCI-460V Fall Across Listed CEC Models?

Distribution marker showing S-Energy Co Ltd SL45-72MCI-460V (460.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where S-Energy Co Ltd SL45-72MCI-460V (460.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCS-Energy Co Ltd SL: 460.0 W

What Dataset Percentiles Define S-Energy Co Ltd SL45-72MCI-460V?

Dataset percentiles tracking S-Energy Co Ltd SL45-72MCI-460V power output, thermal retention ratio, and aperture efficiency against 21,677 models.

S-Energy Co Ltd SL45-72MCI-460V Engineering BenchmarksPercentile comparison of S-Energy Co Ltd SL45-72MCI-460V wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage460.0 WPTC/STC Retention92.9%Module Efficiency21.0%

What Do the Dataset Ranks Show for S-Energy Co Ltd SL45-72MCI-460V?

Benchmark highlights for S-Energy Co Ltd SL45-72MCI-460V covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #5,199 / 21,677

Top 25.0% STC Output

460.0 W STC (+75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,445

21.0% Aperture Efficiency

Power density 210.0 W/m2 (1.09 percentage points above 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.66 V at -10 C (556.6 V string) and 57.16 V at -20 C (10 max).

8 kW Reference Array

18 Panels = 8,280 W STC

Occupies 39.4 m2 (424 sq ft) producing 7,695 W PTC; NEC 690.8 OCPD floor is 18.21 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.4 * (1 + (-0.298/100) * (-10 - 25)) = 55.66 V | OCPD = 1.56 * 11.67 = 18.21 A

Inputs from CEC Modules.csv for S-Energy Co Ltd SL45-72MCI-460V: Voc=50.4 V, beta_Voc=-0.298%/C, Isc=11.67 A, STC=460.0 W, Area=2.19 m2.

Result: 10 panels max on 600 V (556.6 V); 18 panels for 8 kW (424 sq ft).

What Are the Published CEC Specifications for S-Energy Co Ltd SL45-72MCI-460V?

Official CEC datasheet figures for S-Energy Co Ltd SL45-72MCI-460V (Mono-c-Si) used in utility interconnection and permit reviews. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for S-Energy Co Ltd SL45-72MCI-460V.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 460.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 427.5 W (92.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 50.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.67 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.8 V / 11.01 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.298 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.0% (2.19 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many S-Energy Co Ltd SL45-72MCI-460V Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many S-Energy Co Ltd SL45-72MCI-460V modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.44 kW 330 sq ft $1,612 $2,726
8 kW Class 18 8.28 kW 424 sq ft $2,072 $3,504
10 kW Class 22 10.12 kW 519 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This S-Energy Co Ltd Series?

Consolidated S-Energy Co Ltd wattage variants sharing the S-Energy Co Ltd SL45-72MCI-460V mechanical and cell layout. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the S-Energy Co Ltd SL45-72MCI-460V wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
S-Energy Co Ltd SL45-72MCI-450V 450.0 W 418.0 W 50.0 V 41.4 V 20.55%
S-Energy Co Ltd SL45-72MCI-455V 455.0 W 422.7 W 50.2 V 41.6 V 20.78%
S-Energy Co Ltd SL45-72MCI-460V 460.0 W 427.5 W 50.4 V 41.8 V 21.0%
S-Energy Co Ltd SL45-72MCI-465V 465.0 W 432.3 W 50.6 V 42.0 V 21.23%
S-Energy Co Ltd SL45-72MCI-470V 470.0 W 437.1 W 50.8 V 42.2 V 21.46%

How Many S-Energy Co Ltd SL45-72MCI-460V Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on S-Energy Co Ltd SL45-72MCI-460V (55.66 V at 14 F).

Computed from Voc=50.4V and beta_Voc=-0.298%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 57.16 V 10 panels 571.6 V 17 panels
-10 C (14 F) 55.66 V 10 panels 556.6 V 17 panels
0 C (32 F) 54.15 V 11 panels 595.6 V 18 panels
25 C (77 F STC) 50.4 V 11 panels 554.4 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to S-Energy Co Ltd SL45-72MCI-460V?

Competing CEC solar panels closest to S-Energy Co Ltd SL45-72MCI-460V in nameplate wattage and Voc, starting with Heliene 144HC-460.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Heliene 144HC-460
Heliene
460.0 W Tie (0 W) 51.26 V 20.81% 92.4%
CSI Solar Co Ltd CS3W-460MS
CSI Solar Co Ltd
460.0 W Tie (0 W) 49.5 V 21.5% 93.2%
CSI Solar Co Ltd CS3Y-460P
CSI Solar Co Ltd
460.0 W Tie (0 W) 52.0 V 20.09% 93.1%
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S455XI
HD HYUNDAI ENERGY SOLUTIONS CO LTD
455.0 W -5.0 W 50.0 V 20.97% 93.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for S-Energy Co Ltd SL45-72MCI-460V?

Evaluate S-Energy Co Ltd SL45-72MCI-460V (460.0 W STC, 50.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), S-Energy Co Ltd SL45-72MCI-460V reaches 57.16 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 424 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (424 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of S-Energy Co Ltd SL45-72MCI-460V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

S-Energy Co Ltd SL45-72MCI-460V 8 kW Residential Fit

Needs 18 modules (424 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Heliene 144HC-460.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 427.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for S-Energy Co Ltd SL45-72MCI-460V by S-Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many S-Energy Co Ltd SL45-72MCI-460V panels fit on a 600 V winter solar string?

At -10 C (14 F), S-Energy Co Ltd SL45-72MCI-460V cold Voc rises from 50.4 V to 55.66 V (beta_Voc -0.298%/C), capping a 600 V string at 10 panels (556.6 V).

How much roof area does an 8 kW array of S-Energy Co Ltd SL45-72MCI-460V need?

An 8 kW DC system uses 18 S-Energy Co Ltd SL45-72MCI-460V modules (8,280 W STC / 7,695 W PTC), covering roughly 424 sq ft and saving ~$2,072/yr at 18.54 c/kWh.

How does S-Energy Co Ltd SL45-72MCI-460V compare against Heliene 144HC-460?

S-Energy Co Ltd SL45-72MCI-460V outputs 460.0 W STC (50.4 V Voc, rank #5,199 of 21,677), while Heliene 144HC-460 delivers 460.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.