Renesola America JC290F-24/Abh-b is a 290.0 W STC (265.5 W PTC) Mono-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 14.95% efficiency, 45.2 V Voc at 25 C, and 51.72 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 290.0 W
- PTC Wattage
- 265.5 W
- Voc @ 25C
- 45.2 V
- Efficiency
- 14.95%
How Does Renesola America JC290F-24/Abh-b Compare Against Peer CEC Listings?
How Renesola America Renesola America JC290F-24/Abh-b handles rooftop heat (265.5 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Renesola America JC290F-24/Abh-b exhibits 8.45 A short-circuit current, requiring a 13.18 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #17,253 of 21,677 (120.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 54.3 m2 for an 8 kW system (35 panels for 10 kW). Mid-range 45.2 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.
Where Does Renesola America JC290F-24/Abh-b Fall Across Listed CEC Models?
Where Renesola America JC290F-24/Abh-b (290.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Renesola America JC290F-24/Abh-b?
Percentile placement of Renesola America JC290F-24/Abh-b across power density (149.5 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Renesola America JC290F-24/Abh-b?
Four critical engineering numbers homeowners and solar installers check first when reviewing Renesola America JC290F-24/Abh-b specifications. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
290.0 W STC · Higher Than 18.8%
290.0 W STC (-95.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
14.95% Aperture Efficiency
Power density 149.5 W/m2 (4.96 percentage points below 19.91% CEC median). PTC/STC ratio: 91.6% (rank #15,328).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.72 V at -10 C (568.9 V string) and 53.58 V at -20 C (11 max).
28 Panels = 8,120 W STC
Occupies 54.3 m2 (585 sq ft) producing 7,434 W PTC; NEC 690.8 OCPD floor is 13.18 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.2 * (1 + (-0.412/100) * (-10 - 25)) = 51.72 V | OCPD = 1.56 * 8.45 = 13.18 A
Inputs from CEC Modules.csv for Renesola America JC290F-24/Abh-b: Voc=45.2 V, beta_Voc=-0.412%/C, Isc=8.45 A, STC=290.0 W, Area=1.94 m2.
Result: 11 panels max on 600 V (568.9 V); 28 panels for 8 kW (585 sq ft).
What Are the Published CEC Specifications for Renesola America JC290F-24/Abh-b?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Renesola America JC290F-24/Abh-b.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 290.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 265.5 W (91.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.45 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.6 V / 8.15 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.412 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.95% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Renesola America JC290F-24/Abh-b Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Renesola America JC290F-24/Abh-b (290.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.09 kW | 439 sq ft | $1,524 | $2,577 |
| 8 kW Class | 28 | 8.12 kW | 585 sq ft | $2,032 | $3,437 |
| 10 kW Class | 35 | 10.15 kW | 731 sq ft | $2,540 | $4,296 |
How Many Renesola America JC290F-24/Abh-b Modules Fit in a Cold-Weather String?
Maximum series module counts for Renesola America JC290F-24/Abh-b from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.58 V | 11 panels | 589.4 V | 18 panels |
| -10 C (14 F) | 51.72 V | 11 panels | 568.9 V | 19 panels |
| 0 C (32 F) | 49.86 V | 12 panels | 598.3 V | 20 panels |
| 25 C (77 F STC) | 45.2 V | 13 panels | 587.6 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Renesola America JC290F-24/Abh-b?
Alternative CEC solar modules from competing brands near Renesola America JC290F-24/Abh-b (290.0 W), including AXITEC AC-290M/156-72S.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-290M/156-72S AXITEC |
290.0 W | Tie (0 W) | 44.98 V | 14.95% | 90.6% |
| Gintung Energy GTEC-290G6S Gintung Energy |
290.0 W | Tie (0 W) | 44.84 V | 14.83% | 89.7% |
| Gintung Energy GTEC-290G6M Gintung Energy |
290.0 W | Tie (0 W) | 44.61 V | 14.83% | 89.6% |
| Centrosolar America DM72 290 Centrosolar America |
290.0 W | Tie (0 W) | 44.4 V | 14.92% | 90.6% |
What Are the Design Limits and Best-Fit Uses for Renesola America JC290F-24/Abh-b?
Evaluate Renesola America JC290F-24/Abh-b (290.0 W STC, 45.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Renesola America JC290F-24/Abh-b reaches 53.58 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 585 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (585 sq ft).
- 2026 tax credit baseline: cash residential installs of Renesola America JC290F-24/Abh-b carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Renesola America JC290F-24/Abh-b 8 kW Residential Fit
Needs 28 modules (585 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-290M/156-72S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 265.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Renesola America JC290F-24/Abh-b by Renesola America grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Renesola America JC290F-24/Abh-b PTC wattage (265.5 W) lower than STC (290.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 265.5 W PTC (91.6% retention) across Renesola America JC290F-24/Abh-b's 1.94 m2 aperture.
Who should skip Renesola America JC290F-24/Abh-b on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 28 Renesola America JC290F-24/Abh-b panels (585 sq ft) leave unusable roof gaps vs. AXITEC AC-290M/156-72S.
What is the 1,000 V commercial string limit for Renesola America JC290F-24/Abh-b?
On 1,000 V commercial inverters at -10 C (51.72 V cold Voc), Renesola America JC290F-24/Abh-b fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Renesola America JC290F-24/Abh-b.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)