Skip to main content
WireAndSun
Calculators
CEC PV Module

REC Group REC315TP2M — CEC Solar Module Specifications

Manufacturer: REC Group Registry: CEC Verified Engineering Specification

REC Group REC315TP2M is a 315.0 W STC (292.8 W PTC) Mono-c-Si solar module ranking #15,387 of 21,677 CEC listings (below all-CEC median; higher than 27.3% of peers). It delivers 19.48% efficiency, 39.9 V Voc at 25 C, and 43.89 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
315.0 W
PTC Wattage
292.8 W
Voc @ 25C
39.9 V
Efficiency
19.48%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does REC Group REC315TP2M Compare Against Peer CEC Listings?

Solar engineering breakdown for REC Group REC315TP2M: PTC thermal retention, roof footprint, and cold Voc string bounds. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Across 5,889 Mono-c-Si listings from REC Group and peers, REC Group REC315TP2M stands 95.0 W below the 410.0 W Mono-c-Si median and strong 93.0% PTC-to-STC heat retention (#9,879 of 21,677). Sizing 6 kW (20 panels) to 10 kW (32 panels) yields $1,577-$2,523/yr in baseline US bill offset. Lower 39.9 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.

Where Does REC Group REC315TP2M Fall Across Listed CEC Models?

Distribution marker showing REC Group REC315TP2M (315.0 W) relative to the 385.0 W all-CEC solar panel median. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where REC Group REC315TP2M (315.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCREC Group REC315TP: 315.0 W

What Dataset Percentiles Define REC Group REC315TP2M?

Dataset percentiles tracking REC Group REC315TP2M power output, thermal retention ratio, and aperture efficiency against 21,677 models. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

REC Group REC315TP2M Engineering BenchmarksPercentile comparison of REC Group REC315TP2M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage315.0 WPTC/STC Retention93.0%Module Efficiency19.48%

What Do the Dataset Ranks Show for REC Group REC315TP2M?

Benchmark highlights for REC Group REC315TP2M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #15,387 / 21,677

315.0 W STC · Higher Than 27.3%

315.0 W STC (-70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,266

19.48% Aperture Efficiency

Power density 194.8 W/m2 (0.43 percentage points below 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.89 V at -10 C (570.6 V string) and 45.04 V at -20 C (13 max).

8 kW Reference Array

26 Panels = 8,190 W STC

Occupies 42.0 m2 (453 sq ft) producing 7,613 W PTC; NEC 690.8 OCPD floor is 15.68 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.9 * (1 + (-0.286/100) * (-10 - 25)) = 43.89 V | OCPD = 1.56 * 10.05 = 15.68 A

Inputs from CEC Modules.csv for REC Group REC315TP2M: Voc=39.9 V, beta_Voc=-0.286%/C, Isc=10.05 A, STC=315.0 W, Area=1.617 m2.

Result: 13 panels max on 600 V (570.6 V); 26 panels for 8 kW (453 sq ft).

What Are the Published CEC Specifications for REC Group REC315TP2M?

Official CEC datasheet figures for REC Group REC315TP2M (Mono-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC315TP2M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 315.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 292.8 W (93.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.05 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 33.7 V / 9.36 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.286 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.48% (1.617 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many REC Group REC315TP2M Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many REC Group REC315TP2M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.3 kW 348 sq ft $1,577 $2,666
8 kW Class 26 8.19 kW 453 sq ft $2,050 $3,466
10 kW Class 32 10.08 kW 557 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This REC Group Series?

Consolidated REC Group wattage variants sharing the REC Group REC315TP2M mechanical and cell layout. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the REC Group REC315TP2M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
REC Group REC300TP2M 300.0 W 275.7 W 39.5 V 33.0 V 18.52%
REC Group REC305TP2M 305.0 W 280.4 W 39.7 V 33.3 V 18.83%
REC Group REC310TP2M 310.0 W 285.2 W 39.8 V 33.5 V 19.14%
REC Group REC315TP2M 315.0 W 292.8 W 39.9 V 33.7 V 19.48%
REC Group REC320TP2M 320.0 W 297.5 W 40.0 V 33.9 V 19.79%
REC Group REC320TP2M BLK 320.0 W 297.5 W 40.0 V 33.9 V 19.79%

How Many REC Group REC315TP2M Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on REC Group REC315TP2M (43.89 V at 14 F).

Computed from Voc=39.9V and beta_Voc=-0.286%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.04 V 13 panels 585.5 V 22 panels
-10 C (14 F) 43.89 V 13 panels 570.6 V 22 panels
0 C (32 F) 42.75 V 14 panels 598.5 V 23 panels
25 C (77 F STC) 39.9 V 15 panels 598.5 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to REC Group REC315TP2M?

Competing CEC solar panels closest to REC Group REC315TP2M in nameplate wattage and Voc, starting with AXITEC AC-315MH/120S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-315MH/120S
AXITEC
315.0 W Tie (0 W) 39.74 V 18.96% 93.0%
AXITEC AC-315MH/120V
AXITEC
315.0 W Tie (0 W) 39.74 V 18.96% 93.0%
CertainTeed CT315HC11-04
CertainTeed
315.0 W Tie (0 W) 39.74 V 19.58% 92.2%
GCL System Integration Technology Co Ltd GCL-M6/60315
GCL System Integration Technology Co Ltd
315.0 W Tie (0 W) 40.1 V 19.33% 91.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for REC Group REC315TP2M?

Evaluate REC Group REC315TP2M (315.0 W STC, 39.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), REC Group REC315TP2M reaches 45.04 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 453 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (453 sq ft).
  • 2026 tax credit baseline: cash residential installs of REC Group REC315TP2M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

REC Group REC315TP2M 8 kW Residential Fit

Needs 26 modules (453 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-315MH/120S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 292.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC315TP2M by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for REC Group REC315TP2M?

Multiplying REC Group REC315TP2M's 10.05 A short-circuit current by 1.56 equals 15.68 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can REC Group REC315TP2M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.89 V cold Voc at 14 F and handles 10.05 A Isc; string inverters cap REC Group REC315TP2M at 13 panels on 600 V.

Is REC Group REC315TP2M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC315TP2M rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.