Skip to main content
WireAndSun
Calculators
CEC PV Module

AXITEC AC-315MH/120S — CEC Solar Module Specifications

Manufacturer: AXITEC Registry: CEC Verified Engineering Specification

AXITEC AC-315MH/120S is a 315.0 W STC (292.8 W PTC) Mono-c-Si solar module ranking #15,387 of 21,677 CEC listings (below all-CEC median; higher than 27.3% of peers). It delivers 18.96% efficiency, 39.74 V Voc at 25 C, and 43.69 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
315.0 W
PTC Wattage
292.8 W
Voc @ 25C
39.74 V
Efficiency
18.96%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AXITEC AC-315MH/120S Compare Against Peer CEC Listings?

How AXITEC AXITEC AC-315MH/120S handles rooftop heat (292.8 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, AXITEC AC-315MH/120S exhibits 10.04 A short-circuit current, requiring a 15.66 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #15,387 of 21,677 (95.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 43.2 m2 for an 8 kW system (32 panels for 10 kW). Lower 39.74 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.

Where Does AXITEC AC-315MH/120S Fall Across Listed CEC Models?

Where AXITEC AC-315MH/120S (315.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AXITEC AC-315MH/120S (315.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAXITEC AC-315MH/12: 315.0 W

What Dataset Percentiles Define AXITEC AC-315MH/120S?

Percentile placement of AXITEC AC-315MH/120S across power density (189.5 W/m2), thermal retention, and nameplate STC wattage.

AXITEC AC-315MH/120S Engineering BenchmarksPercentile comparison of AXITEC AC-315MH/120S wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage315.0 WPTC/STC Retention93.0%Module Efficiency18.96%

What Do the Dataset Ranks Show for AXITEC AC-315MH/120S?

Four critical engineering numbers homeowners and solar installers check first when reviewing AXITEC AC-315MH/120S specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #15,387 / 21,677

315.0 W STC · Higher Than 27.3%

315.0 W STC (-70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,528

18.96% Aperture Efficiency

Power density 189.5 W/m2 (0.95 percentage points below 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.69 V at -10 C (568.0 V string) and 44.82 V at -20 C (13 max).

8 kW Reference Array

26 Panels = 8,190 W STC

Occupies 43.2 m2 (465 sq ft) producing 7,613 W PTC; NEC 690.8 OCPD floor is 15.66 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.74 * (1 + (-0.284/100) * (-10 - 25)) = 43.69 V | OCPD = 1.56 * 10.04 = 15.66 A

Inputs from CEC Modules.csv for AXITEC AC-315MH/120S: Voc=39.74 V, beta_Voc=-0.284%/C, Isc=10.04 A, STC=315.0 W, Area=1.662 m2.

Result: 13 panels max on 600 V (568.0 V); 26 panels for 8 kW (465 sq ft).

What Are the Published CEC Specifications for AXITEC AC-315MH/120S?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for AXITEC AC-315MH/120S.

Official California Energy Commission (NREL SAM) test parameters for AXITEC AC-315MH/120S.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 315.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 292.8 W (93.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.74 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.04 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.79 V / 9.6 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.284 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.96% (1.662 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many AXITEC AC-315MH/120S Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using AXITEC AC-315MH/120S (315.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.3 kW 358 sq ft $1,577 $2,666
8 kW Class 26 8.19 kW 465 sq ft $2,050 $3,466
10 kW Class 32 10.08 kW 572 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?

All closely matched AXITEC wattages and cosmetic trims sharing the AXITEC AC-315MH/120S architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the AXITEC AC-315MH/120S wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
AXITEC AC-305MH/120S 305.0 W 283.3 W 39.42 V 32.37 V 18.36%
AXITEC AC-310MH/120S 310.0 W 288.0 W 39.58 V 32.58 V 18.66%
AXITEC AC-315MH/120S 315.0 W 292.8 W 39.74 V 32.79 V 18.96%
AXITEC AC-320MH/120S 320.0 W 297.6 W 39.92 V 33.01 V 19.26%

How Many AXITEC AC-315MH/120S Modules Fit in a Cold-Weather String?

Maximum series module counts for AXITEC AC-315MH/120S from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=39.74V and beta_Voc=-0.284%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.82 V 13 panels 582.7 V 22 panels
-10 C (14 F) 43.69 V 13 panels 568.0 V 22 panels
0 C (32 F) 42.56 V 14 panels 595.8 V 23 panels
25 C (77 F STC) 39.74 V 15 panels 596.1 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-315MH/120S?

Alternative CEC solar modules from competing brands near AXITEC AC-315MH/120S (315.0 W), including CertainTeed CT315HC11-04. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CertainTeed CT315HC11-04
CertainTeed
315.0 W Tie (0 W) 39.74 V 19.58% 92.2%
GCL System Integration Technology Co Ltd GCL-M6/60315
GCL System Integration Technology Co Ltd
315.0 W Tie (0 W) 40.1 V 19.33% 91.3%
CSI Solar Co Ltd CS3K-310MS
CSI Solar Co Ltd
310.0 W -5.0 W 39.7 V 19.34% 93.1%
GCL System Integration Technology Co Ltd GCL-M6/60310
GCL System Integration Technology Co Ltd
310.0 W -5.0 W 39.9 V 19.02% 91.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AXITEC AC-315MH/120S?

Evaluate AXITEC AC-315MH/120S (315.0 W STC, 39.74 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-315MH/120S reaches 44.82 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 465 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (465 sq ft).
  • 2026 tax credit baseline: cash residential installs of AXITEC AC-315MH/120S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AXITEC AC-315MH/120S 8 kW Residential Fit

Needs 26 modules (465 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CertainTeed CT315HC11-04.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 292.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AXITEC AC-315MH/120S by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.

Why is AXITEC AC-315MH/120S PTC wattage (292.8 W) lower than STC (315.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 292.8 W PTC (93.0% retention) across AXITEC AC-315MH/120S's 1.662 m2 aperture.

Who should skip AXITEC AC-315MH/120S on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 26 AXITEC AC-315MH/120S panels (465 sq ft) leave unusable roof gaps vs. CertainTeed CT315HC11-04.

What is the 1,000 V commercial string limit for AXITEC AC-315MH/120S?

On 1,000 V commercial inverters at -10 C (43.69 V cold Voc), AXITEC AC-315MH/120S fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting AXITEC AC-315MH/120S.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.