CSI Solar Co Ltd CS3K-310MS is a 310.0 W STC (288.6 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 19.34% efficiency, 39.7 V Voc at 25 C, and 43.76 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 310.0 W
- PTC Wattage
- 288.6 W
- Voc @ 25C
- 39.7 V
- Efficiency
- 19.34%
How Does CSI Solar Co Ltd CS3K-310MS Compare Against Peer CEC Listings?
Solar engineering breakdown for CSI Solar Co Ltd CS3K-310MS: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from CSI Solar Co Ltd and peers, CSI Solar Co Ltd CS3K-310MS stands 100.0 W below the 410.0 W Mono-c-Si median and strong 93.1% PTC-to-STC heat retention (#9,420 of 21,677). Sizing 6 kW (20 panels) to 10 kW (33 panels) yields $1,552-$2,560/yr in baseline US bill offset. Lower 39.7 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.
Where Does CSI Solar Co Ltd CS3K-310MS Fall Across Listed CEC Models?
Distribution marker showing CSI Solar Co Ltd CS3K-310MS (310.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define CSI Solar Co Ltd CS3K-310MS?
Dataset percentiles tracking CSI Solar Co Ltd CS3K-310MS power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for CSI Solar Co Ltd CS3K-310MS?
Benchmark highlights for CSI Solar Co Ltd CS3K-310MS covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
310.0 W STC · Higher Than 25.6%
310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.34% Aperture Efficiency
Power density 193.4 W/m2 (0.57 percentage points below 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.76 V at -10 C (568.9 V string) and 44.92 V at -20 C (13 max).
26 Panels = 8,060 W STC
Occupies 41.7 m2 (449 sq ft) producing 7,504 W PTC; NEC 690.8 OCPD floor is 15.57 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.7 * (1 + (-0.292/100) * (-10 - 25)) = 43.76 V | OCPD = 1.56 * 9.98 = 15.57 A
Inputs from CEC Modules.csv for CSI Solar Co Ltd CS3K-310MS: Voc=39.7 V, beta_Voc=-0.292%/C, Isc=9.98 A, STC=310.0 W, Area=1.603 m2.
Result: 13 panels max on 600 V (568.9 V); 26 panels for 8 kW (449 sq ft).
What Are the Published CEC Specifications for CSI Solar Co Ltd CS3K-310MS?
Official CEC datasheet figures for CSI Solar Co Ltd CS3K-310MS (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 288.6 W (93.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.98 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.9 V / 9.43 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.292 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.34% (1.603 m2) | Array roof footprint density |
| Cell Count & Technology | 3 cells (Mono-c-Si) | Monofacial backsheet |
How Many CSI Solar Co Ltd CS3K-310MS Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many CSI Solar Co Ltd CS3K-310MS modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.2 kW | 345 sq ft | $1,552 | $2,624 |
| 8 kW Class | 26 | 8.06 kW | 449 sq ft | $2,017 | $3,411 |
| 10 kW Class | 33 | 10.23 kW | 569 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?
Consolidated CSI Solar Co Ltd wattage variants sharing the CSI Solar Co Ltd CS3K-310MS mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3K-300MS | 300.0 W | 279.0 W | 39.3 V | 32.5 V | 18.71% |
| CSI Solar Co Ltd CS3K-305MS | 305.0 W | 283.8 W | 39.5 V | 32.7 V | 19.03% |
| CSI Solar Co Ltd CS3K-310MS | 310.0 W | 288.6 W | 39.7 V | 32.9 V | 19.34% |
| CSI Solar Co Ltd CS3K-315MS | 315.0 W | 293.3 W | 39.9 V | 33.1 V | 19.65% |
How Many CSI Solar Co Ltd CS3K-310MS Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on CSI Solar Co Ltd CS3K-310MS (43.76 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.92 V | 13 panels | 584.0 V | 22 panels |
| -10 C (14 F) | 43.76 V | 13 panels | 568.9 V | 22 panels |
| 0 C (32 F) | 42.6 V | 14 panels | 596.4 V | 23 panels |
| 25 C (77 F STC) | 39.7 V | 15 panels | 595.5 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS3K-310MS?
Competing CEC solar panels closest to CSI Solar Co Ltd CS3K-310MS in nameplate wattage and Voc, starting with GCL System Integration Technology Co Ltd GCL-M6/60310.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-M6/60310 GCL System Integration Technology Co Ltd |
310.0 W | Tie (0 W) | 39.9 V | 19.02% | 91.3% |
| Boviet Solar Technology Co Ltd BVM6610M-310 Boviet Solar Technology Co Ltd |
310.0 W | Tie (0 W) | 40.1 V | 19.05% | 92.2% |
| Boviet Solar Technology Co Ltd BVM6610M-310-H Boviet Solar Technology Co Ltd |
310.0 W | Tie (0 W) | 40.1 V | 19.02% | 93.1% |
| Boviet Solar Technology Co Ltd BVM6610M-W5-310-H Boviet Solar Technology Co Ltd |
310.0 W | Tie (0 W) | 40.1 V | 19.05% | 93.1% |
What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS3K-310MS?
Evaluate CSI Solar Co Ltd CS3K-310MS (310.0 W STC, 39.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS3K-310MS reaches 44.92 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 449 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (449 sq ft).
- 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS3K-310MS carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CSI Solar Co Ltd CS3K-310MS 8 kW Residential Fit
Needs 26 modules (449 sq ft) with a 20 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/60310.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 288.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CSI Solar Co Ltd CS3K-310MS by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for CSI Solar Co Ltd CS3K-310MS?
Multiplying CSI Solar Co Ltd CS3K-310MS's 9.98 A short-circuit current by 1.56 equals 15.57 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can CSI Solar Co Ltd CS3K-310MS pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 43.76 V cold Voc at 14 F and handles 9.98 A Isc; string inverters cap CSI Solar Co Ltd CS3K-310MS at 13 panels on 600 V.
Is CSI Solar Co Ltd CS3K-310MS eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of CSI Solar Co Ltd CS3K-310MS rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)