AXITEC AC-315MH/120V is a 315.0 W STC (292.8 W PTC) Mono-c-Si solar module ranking #15,387 of 21,677 CEC listings (below all-CEC median; higher than 27.3% of peers). It delivers 18.96% efficiency, 39.74 V Voc at 25 C, and 43.69 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 315.0 W
- PTC Wattage
- 292.8 W
- Voc @ 25C
- 39.74 V
- Efficiency
- 18.96%
How Does AXITEC AC-315MH/120V Compare Against Peer CEC Listings?
Engineering position of AXITEC AC-315MH/120V (315.0 W STC) vs. CertainTeed CT315HC11-04 across 5,889 CEC Mono-c-Si solar modules.
Ranking #15,387 across 21,677 CEC solar panels (below all-CEC median; higher than 27.3% of peers), AXITEC AC-315MH/120V operates as a compact residential or specialty off-grid module sitting 95.0 W below the 410.0 W Mono-c-Si median. Lower 39.74 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters. With strong 93.0% PTC-to-STC heat retention (#9,879 of 21,677), 26 panels occupy 465 sq ft and offset roughly $2,050/yr at average US rates (or $3,466/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does AXITEC AC-315MH/120V Fall Across Listed CEC Models?
Plots AXITEC AC-315MH/120V at 315.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define AXITEC AC-315MH/120V?
Benchmarks AXITEC AC-315MH/120V on STC wattage, thermal PTC/STC retention, and 18.96 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for AXITEC AC-315MH/120V?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for AXITEC AC-315MH/120V by AXITEC.
315.0 W STC · Higher Than 27.3%
315.0 W STC (-70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.96% Aperture Efficiency
Power density 189.5 W/m2 (0.95 percentage points below 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.69 V at -10 C (568.0 V string) and 44.82 V at -20 C (13 max).
26 Panels = 8,190 W STC
Occupies 43.2 m2 (465 sq ft) producing 7,613 W PTC; NEC 690.8 OCPD floor is 15.66 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.74 * (1 + (-0.284/100) * (-10 - 25)) = 43.69 V | OCPD = 1.56 * 10.04 = 15.66 A
Inputs from CEC Modules.csv for AXITEC AC-315MH/120V: Voc=39.74 V, beta_Voc=-0.284%/C, Isc=10.04 A, STC=315.0 W, Area=1.662 m2.
Result: 13 panels max on 600 V (568.0 V); 26 panels for 8 kW (465 sq ft).
What Are the Published CEC Specifications for AXITEC AC-315MH/120V?
Laboratory test ratings recorded for AXITEC AC-315MH/120V (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 315.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 292.8 W (93.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.74 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.04 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.79 V / 9.6 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.284 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.96% (1.662 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many AXITEC AC-315MH/120V Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (465 sq ft at 8 kW), and estimated Year-1 electric bill offset for AXITEC AC-315MH/120V.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.3 kW | 358 sq ft | $1,577 | $2,666 |
| 8 kW Class | 26 | 8.19 kW | 465 sq ft | $2,050 | $3,466 |
| 10 kW Class | 32 | 10.08 kW | 572 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?
Sibling wattage bins and frame colors grouped with AXITEC AC-315MH/120V under AXITEC to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| AXITEC AC-305MH/120V | 305.0 W | 283.3 W | 39.42 V | 32.37 V | 18.36% |
| AXITEC AC-310MH/120V | 310.0 W | 288.0 W | 39.58 V | 32.58 V | 18.66% |
| AXITEC AC-315MH/120V | 315.0 W | 292.8 W | 39.74 V | 32.79 V | 18.96% |
| AXITEC AC-320MH/120V | 320.0 W | 297.6 W | 39.92 V | 33.01 V | 19.26% |
How Many AXITEC AC-315MH/120V Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for AXITEC AC-315MH/120V (beta_Voc -0.284%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.82 V | 13 panels | 582.7 V | 22 panels |
| -10 C (14 F) | 43.69 V | 13 panels | 568.0 V | 22 panels |
| 0 C (32 F) | 42.56 V | 14 panels | 595.8 V | 23 panels |
| 25 C (77 F STC) | 39.74 V | 15 panels | 596.1 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-315MH/120V?
Closest cross-brand CEC competitors to AXITEC AC-315MH/120V matched near 315.0 W STC and 39.74 V Voc, led by CertainTeed CT315HC11-04.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CertainTeed CT315HC11-04 CertainTeed |
315.0 W | Tie (0 W) | 39.74 V | 19.58% | 92.2% |
| GCL System Integration Technology Co Ltd GCL-M6/60315 GCL System Integration Technology Co Ltd |
315.0 W | Tie (0 W) | 40.1 V | 19.33% | 91.3% |
| CSI Solar Co Ltd CS3K-310MS CSI Solar Co Ltd |
310.0 W | -5.0 W | 39.7 V | 19.34% | 93.1% |
| GCL System Integration Technology Co Ltd GCL-M6/60310 GCL System Integration Technology Co Ltd |
310.0 W | -5.0 W | 39.9 V | 19.02% | 91.3% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-315MH/120V?
Evaluate AXITEC AC-315MH/120V (315.0 W STC, 39.74 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-315MH/120V reaches 44.82 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 465 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (465 sq ft).
- 2026 tax credit baseline: cash residential installs of AXITEC AC-315MH/120V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-315MH/120V 8 kW Residential Fit
Needs 26 modules (465 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CertainTeed CT315HC11-04.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 292.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-315MH/120V by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
How many AXITEC AC-315MH/120V panels fit on a 600 V winter solar string?
At -10 C (14 F), AXITEC AC-315MH/120V cold Voc rises from 39.74 V to 43.69 V (beta_Voc -0.284%/C), capping a 600 V string at 13 panels (568.0 V).
How much roof area does an 8 kW array of AXITEC AC-315MH/120V need?
An 8 kW DC system uses 26 AXITEC AC-315MH/120V modules (8,190 W STC / 7,613 W PTC), covering roughly 465 sq ft and saving ~$2,050/yr at 18.54 c/kWh.
How does AXITEC AC-315MH/120V compare against CertainTeed CT315HC11-04?
AXITEC AC-315MH/120V outputs 315.0 W STC (39.74 V Voc, rank #15,387 of 21,677), while CertainTeed CT315HC11-04 delivers 315.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)